Stability of two anterior fixations for three-column injury in the lower cervical spine: biomechanical evaluation of anterior pedicle screw-plate fixation

被引:5
|
作者
Wu, Hai-hao [1 ]
Tang, Tao [1 ]
Yu, Xiao [1 ]
Pang, Qing-jiang [1 ]
机构
[1] Ningbo 2 Hosp, Dept Orthoped, 41 Xibei St, Ningbo 315010, Zhejiang, Peoples R China
关键词
Lower cervical spine; anterior pedicle screw-plate; three-column injury; stability; biomechanics; range of motion; CLASSIFICATION-SYSTEM;
D O I
10.1177/0300060517734687
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives This study aimed to evaluate the stability of anterior pedicle screw-plate (APSP) fixation and anterior vertebral body screw-plate (AVBSP) fixation for three-column injury in the lower cervical spine. Methods Six fresh-frozen human cadaveric specimens of the lower cervical spine were prepared. After measurement of the range of motion (ROM) in the intact state, the specimens were prepared as three-column injury models. The models were stabilized by AVBSP or APSP fixation. The ROM of the models in the two states was measured. The ROM in the two states was compared. Results The ROM of the intact state in all directions was significantly smaller than that of the AVBSP state and significantly larger than that of the APSP state. The ROM of the AVBSP state in all directions was significantly larger than that of the APSP state. Conclusions This study shows that APSP fixation can provide sufficient stability for three-column injury in the lower cervical spine. The primary stability of our models using APSP fixation is superior to that of AVBSP fixation. These results suggest that APSP can be used for three-column injury in the lower cervical spine.
引用
收藏
页码:1455 / 1460
页数:6
相关论文
共 50 条
  • [1] Biomechanical Comparison of Anterior Lumbar Screw-plate Fixation versus Posterior Lumbar Pedicle Screw Fixation
    刘列华
    郭从涛
    周强
    蒲小兵
    宋磊
    王浩明
    赵晨
    成仕明
    兰阳军
    刘岭
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2014, 34 (06) : 907 - 911
  • [2] Biomechanical comparison of anterior lumbar screw-plate fixation versus posterior lumbar pedicle screw fixation
    Lie-hua Liu
    Cong-tao Guo
    Qiang Zhou
    Xiao-bing Pu
    Lei Song
    Hao-ming Wang
    Chen Zhao
    Shi-ming Cheng
    Yang-jun Lan
    Ling Liu
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2014, 34 : 907 - 911
  • [3] Biomechanical comparison of anterior lumbar screw-plate fixation versus posterior lumbar pedicle screw fixation
    Liu, Lie-hua
    Guo, Cong-tao
    Zhou, Qiang
    Pu, Xiao-bing
    Song, Lei
    Wang, Hao-ming
    Zhao, Chen
    Cheng, Shi-ming
    Lan, Yang-jun
    Liu, Ling
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (06) : 907 - 911
  • [4] EFFECTS OF ANTERIOR VERTEBRAL GRAFTING ON THE TRAUMATIZED LUMBAR SPINE AFTER PEDICLE SCREW-PLATE FIXATION
    MAIMAN, DJ
    PINTAR, F
    YOGANANDAN, N
    REINARTZ, J
    SPINE, 1993, 18 (16) : 2423 - 2430
  • [5] Is Anterior-Only Fixation Adequate for Three-Column Injuries of the Cervical Spine?
    Sethy, Siddharth Sekhar
    Ahuja, Kaustubh
    Ifthekar, Syed
    Sarkar, Bhaskar
    Kandwal, Pankaj
    ASIAN SPINE JOURNAL, 2021, 15 (01) : 72 - 80
  • [6] Biomechanical analysis of rigid stabilization techniques for three-column injury in the lower cervical spine
    Bozkus, H
    Ames, CP
    Chamberlain, RH
    Nottmeier, EW
    Sonntag, VKH
    Papadopoulos, SM
    Crawford, NR
    SPINE, 2005, 30 (08) : 915 - 922
  • [7] Letter to the Editor: Is Anterior-Only Fixation Adequate for Three-Column Injuries of the Cervical Spine?
    Viswanathan, Vibhu Krishnan
    Subramanian, Surabhi
    ASIAN SPINE JOURNAL, 2021, 15 (03) : 408 - 409
  • [8] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Lehmann, W
    Blauth, M
    Briem, D
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 69 - 75
  • [9] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Wolfgang Lehmann
    Michael Blauth
    Daniel Briem
    Ulf Schmidt
    European Spine Journal, 2004, 13 : 69 - 75
  • [10] ANTERIOR CERVICAL FIXATION WITH THE TITANIUM LOCKING SCREW-PLATE - A PRELIMINARY-REPORT
    TOMINAGA, T
    KOSHU, K
    MIZOI, K
    YOSHIMOTO, T
    SURGICAL NEUROLOGY, 1994, 42 (05): : 408 - 413