CO2 microbubble contrast enhancement in x-ray angiography

被引:6
|
作者
Kariya, S. [1 ]
Komemushi, A. [1 ]
Nakatani, M. [1 ]
Yoshida, R. [1 ]
Sawada, S. [1 ]
Tanigawa, N. [1 ]
机构
[1] Kansai Med Univ, Dept Radiol, Hirakata, Osaka 5731191, Japan
基金
日本科学技术振兴机构;
关键词
ULTRASOUND; TISSUE;
D O I
10.1016/j.crad.2012.08.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To demonstrate that carbon dioxide (CO2) microbubble contrast enhancement depicts blood vessels when used for x-ray examinations. MATERIALS AND METHODS: Microbubbles were generated by cavitation of physiological saline to which CO2 gas had been added using an ejector-type microbubble generator. The input pressure values for CO2 gas and physiological saline that produced a large quantity of CO2 microbubbles were obtained in a phantom. In an animal study, angiography was performed in three swine using three types of contrast: CO2 microbubbles, conventional CO2 gas, and iodinated contrast medium. For CO2 microbubble contrast enhancement, physiological saline, and CO2 gas were supplied at the input pressures calculated in the phantom experiment. Regions of interest were set in the abdominal aorta, external iliac arteries, and background. The difference in digital values between each artery and the background was calculated. RESULTS: The input pressures obtained in the phantom experiment were 0.16 MPa for physiological saline and 0.5 MPa for CO2 gas, with physiological saline input volume being 8.1 ml/s. Three interventional radiologists all evaluated the depictions of all arteries as "present" in the CO2 microbubble contrast enhancement, conventional CO2 contrast enhancement, and iodinated contrast enhancement performed in three swine. Digital values for all vessels with microbubble CO2 contrast enhancement were higher than background values. CONCLUSIONS: In x-ray angiography, blood vessels can be depicted by CO2 microbubble contrast enhancement, in which a large quantity of CO2 microbubbles is generated within blood vessels. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 50 条
  • [1] Re: CO2 microbubble contrast enhancement in x-ray angiography
    Patel, J. V.
    Kesser, David
    CLINICAL RADIOLOGY, 2013, 68 (11) : 1179 - 1180
  • [2] Re: CO2 microbubble contrast enhancement in x-ray angiography. A reply
    Kariya, S.
    Komemushi, A.
    Nakatani, M.
    Yoshida, R.
    Sawada, S.
    Tanigawa, N.
    CLINICAL RADIOLOGY, 2013, 68 (11) : 1180 - 1180
  • [3] X-ray phase contrast angiography using CO2 as contrast agent
    Lundstrom, Ulf
    Larsson, Daniel H.
    Takman, Per A. C.
    Scott, Lena
    Burvall, Anna
    Hertz, Hans M.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] X-ray phase contrast for CO2 microangiography
    Lundstrom, U.
    Larsson, D. H.
    Burvall, A.
    Takman, P. A. C.
    Scott, L.
    Brismar, H.
    Hertz, H. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [5] X-ray phase-contrast CO2 angiography for sub-10 μm vessel imaging
    Lundstrom, U.
    Larsson, D. H.
    Burvall, A.
    Scott, L.
    Westermark, U. K.
    Wilhelm, M.
    Henriksson, M. Arsenian
    Hertz, H. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (22): : 7431 - 7441
  • [6] Evaluation of microbubble contrast agents for dynamic imaging with x-ray phase contrast
    Millard, T. P.
    Endrizzi, M.
    Everdell, N.
    Rigon, L.
    Arfelli, F.
    Menk, R. H.
    Stride, E.
    Olivo, A.
    SCIENTIFIC REPORTS, 2015, 5
  • [7] Evaluation of microbubble contrast agents for dynamic imaging with x-ray phase contrast
    T. P. Millard
    M. Endrizzi
    N. Everdell
    L. Rigon
    F. Arfelli
    R. H. Menk
    E. Stride
    A. Olivo
    Scientific Reports, 5
  • [8] Contrast enhancement in X-ray phase contrast tomography
    1600, Optical Society of America (OSA) (22):
  • [9] Contrast enhancement in X-ray phase contrast tomography
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Singh, Bipin
    Barbastathis, George
    OPTICS EXPRESS, 2014, 22 (15): : 18020 - 18026
  • [10] ELECTRONIC ENHANCEMENT OF X-RAY FILM CONTRAST
    GARVIN, JS
    GOODWIN, CW
    SCIENCE, 1949, 110 (2862) : 481 - 481