Air velocity distribution analysis in the air duct of a display cabinet by PIV technique

被引:15
|
作者
Marinetti, Sergio [1 ]
Cavazzini, Giovanna [2 ]
Fedele, Laura [1 ]
De Zan, Francesco [1 ]
Schiesaro, Pierluigi [3 ]
机构
[1] CNR, Construct Technol Inst, I-35127 Padua, Italy
[2] Univ Padua, Dept Ind Engn, I-35131 Padua, Italy
[3] Arneg SpA, I-35010 Campo San Martino, PD, Italy
关键词
Particle Image Velocimetry (PIV); Display cabinet; Heat exchange; Efficiency; FLOW MALDISTRIBUTION; PERFORMANCE;
D O I
10.1016/j.ijrefrig.2012.07.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work is aimed at presenting an analysis, by stereoscopic Particle Image Velocimetry (PIV) technique, of the air speed distribution inside the cooling duct of a display cabinet and its effect on the heat exchange efficiency. Two configurations of the duct, in which the air is forced through the evaporator by one and two fans, respectively, are tested. 3D flow fields, upstream and downstream the evaporator, are determined by PIV performed on three planes containing the mainstream velocity vectors and placed at different heights. Measurements are carried out at the maximum fan rotation rate. The analysis of the air flow distribution at the inlet and outlet of the evaporator shows the capabilities of the PIV technique to highlight insufficiently loaded sections of the evaporator and to estimate the energy transfer efficiency. These results are compared with those of an ideal configuration, in which the air flow rate is uniformly distributed at the evaporator entrance. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:2321 / 2331
页数:11
相关论文
共 50 条
  • [1] AIR VELOCITY DITRIBUTION ANALYSIS IN THE AIR DUCT OF A DISPLAY CABINET BY PIV TECHNIQUE
    Marinetti, S.
    Cavazzini, G.
    Fedele, L.
    De Zan, F.
    Schiesaro, P.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2315 - +
  • [2] Numerical and experimental analysis of the air flow distribution in the cooling duct of a display cabinet
    Marinetti, Sergio
    Cauazzini, Giovanna
    Lauri, Igor
    Testa, Samuele
    Minetto, Silvia
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 8 - 13
  • [3] NUMERICAL ANALYSIS OF A COMMERCIAL DISPLAY CABINET WITH AIR CURTAIN
    Caliskan, Sinan
    Altunok, Taner
    Baskaya, Senol
    Gungunes, H. Murat
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2011, 26 (02): : 414 - 424
  • [4] Numerical Investigation of Air Curtain Velocity Ratio in an Open Refrigerated Display Cabinet with Dual Air Curtain
    Cheng, Po-Shen
    Hsieh, Chia-Hsing
    Yu, Pei-Yu
    26TH IIR INTERNATIONAL CONGRESS OF REFRIGERATION, VOL 3, 2023, : 509 - 518
  • [5] Numerical modelling and validation of the air flow maldistribution in the cooling duct of a horizontal display cabinet
    Rossetti, Antonio
    Minetto, Silvia
    Marinetti, Sergio
    APPLIED THERMAL ENGINEERING, 2015, 87 : 24 - 33
  • [6] Air-flow distribution simulation and experimental analysis of a new testing room for refrigerated display cabinet
    Huang, Chao
    Wang, Fang
    Wu, Zhimin
    Guo, Chao
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 701 - 706
  • [7] Air-flow distribution simulation and experimental analysis of a new testing room for refrigerated display cabinet
    College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    Shanghai Ligong Daxue Xuebao, 2007, 4 (353-357):
  • [8] AIR-JET DEFLECTION MEASURES DUCT AIR VELOCITY
    HOGAN, BJ
    DESIGN NEWS, 1978, 34 (05) : 48 - 49
  • [9] AN ENVIRONMENTAL CABINET WITH VARIABLE AIR VELOCITY FOR INSECT STUDIES
    SCOTT, KR
    CANADIAN ENTOMOLOGIST, 1968, 100 (01): : 89 - &
  • [10] Performance of an open refrigerated display cabinet with two air curtains
    Li, Xueqiang
    Zhang, Zhongyao
    Liu, Huan
    Hu, Xiuzhen
    Liu, Shengchun
    Xu, Zhiming
    Wang, Qihui
    APPLIED THERMAL ENGINEERING, 2022, 212