Repeatability and variation of region-of-interest methods using quantitative diffusion tensor MR imaging of the brain

被引:49
|
作者
Hakulinen, Ullamari [1 ,2 ]
Brander, Antti [1 ]
Ryymin, Pertti [1 ]
Ohman, Juha [3 ]
Soimakallio, Seppo [1 ,4 ]
Helminen, Mika [5 ]
Dastidar, Prasun [1 ,4 ]
Eskola, Hannu [1 ,2 ]
机构
[1] Pirkanmaa Hosp Dist, Med Imaging Ctr, Dept Radiol, Tampere 33521, Finland
[2] Tampere Univ Technol, Dept Biomed Engn, FIN-33101 Tampere, Finland
[3] Tampere Univ Hosp, Dept Neurosurg, Tampere, Finland
[4] Univ Tampere, Tampere Med Sch, FIN-33101 Tampere, Finland
[5] Pirkanmaa Hosp Dist, Ctr Sci, Tampere 33521, Finland
来源
BMC MEDICAL IMAGING | 2012年 / 12卷
关键词
WHITE-MATTER MICROSTRUCTURE; TO-NOISE RATIO; FRACTIONAL ANISOTROPY; REPRODUCIBILITY; 3T; SCHIZOPHRENIA; CHILDREN; STATE; DTI;
D O I
10.1186/1471-2342-12-30
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Diffusion tensor imaging (DTI) is increasingly used in various diseases as a clinical tool for assessing the integrity of the brain's white matter. Reduced fractional anisotropy (FA) and an increased apparent diffusion coefficient (ADC) are nonspecific findings in most pathological processes affecting the brain's parenchyma. At present, there is no gold standard for validating diffusion measures, which are dependent on the scanning protocols, methods of the softwares and observers. Therefore, the normal variation and repeatability effects on commonly-derived measures should be carefully examined. Methods: Thirty healthy volunteers (mean age 37.8 years, SD 11.4) underwent DTI of the brain with 3T MRI. Region-of-interest (ROI) -based measurements were calculated at eleven anatomical locations in the pyramidal tracts, corpus callosum and frontobasal area. Two ROI-based methods, the circular method (CM) and the freehand method (FM), were compared. Both methods were also compared by performing measurements on a DTI phantom. The intra-and inter-observer variability (coefficient of variation, or CV%) and repeatability (intra-class correlation coefficient, or ICC) were assessed for FA and ADC values obtained using both ROI methods. Results: The mean FA values for all of the regions were 0.663 with the CM and 0.621 with the FM. For both methods, the FA was highest in the splenium of the corpus callosum. The mean ADC value was 0.727 x 10(-3) mm(2)/s with the CM and 0.747 x 10(-3) mm(2)/s with the FM, and both methods found the ADC to be lowest in the corona radiata. The CV percentages of the derived measures were < 13% with the CM and < 10% with the FM. In most of the regions, the ICCs were excellent or moderate for both methods. With the CM, the highest ICC for FA was in the posterior limb of the internal capsule (0.90), and with the FM, it was in the corona radiata (0.86). For ADC, the highest ICC was found in the genu of the corpus callosum (0.93) with the CM and in the uncinate fasciculus (0.92) with FM. Conclusions: With both ROI-based methods variability was low and repeatability was moderate. The circular method gave higher repeatability, but variation was slightly lower using the freehand method. The circular method can be recommended for the posterior limb of the internal capsule and splenium of the corpus callosum, and the freehand method for the corona radiata.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Repeatability and variation of region-of-interest methods using quantitative diffusion tensor MR imaging of the brain
    Ullamari Hakulinen
    Antti Brander
    Pertti Ryymin
    Juha Öhman
    Seppo Soimakallio
    Mika Helminen
    Prasun Dastidar
    Hannu Eskola
    BMC Medical Imaging, 12
  • [2] Intra- and Inter-observer Variation of Region-of-Interest Methods in Quantitative Clinical Diffusion Tensor Imaging
    Hakulinen, U.
    Brander, A.
    Ryymin, P.
    Ohman, J.
    Soimakallio, S.
    Dastidar, P.
    Eskola, H.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 551 - +
  • [3] Reliability of the freehand region-of-interest method in quantitative cerebral diffusion tensor imaging
    Hakulinen, Ullamari
    Brander, Antti
    Ilvesmaki, Tero
    Helminen, Mika
    Ohman, Juha
    Luoto, Teemu M.
    Eskola, Hannu
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [4] Reliability of the freehand region-of-interest method in quantitative cerebral diffusion tensor imaging
    Ullamari Hakulinen
    Antti Brander
    Tero Ilvesmäki
    Mika Helminen
    Juha Öhman
    Teemu M. Luoto
    Hannu Eskola
    BMC Medical Imaging, 21
  • [5] Comparison of region-of-interest delineation methods for diffusion tensor imaging in patients with cervical spondylotic radiculopathy
    Wu, Penghuan
    Huang, Chengyan
    Shi, Benchao
    Jin, Anmin
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [6] Comparison of region-of-interest delineation methods for diffusion tensor imaging in patients with cervical spondylotic radiculopathy
    Penghuan Wu
    Chengyan Huang
    Benchao Shi
    Anmin Jin
    BMC Musculoskeletal Disorders, 23
  • [7] Region-of-interest (ROI) versus tractography analysis of the corticospinal tract using diffusion tensor imaging
    Ontaneda, D.
    Sakaie, K.
    Atthe, B.
    Lin, J.
    Wang, X.
    Lowe, M. J.
    Phillips, M.
    Fox, R. J.
    MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (11) : 428 - 428
  • [8] Effect of Region of Interest Size on the Repeatability of Quantitative Brain Imaging Biomarkers
    Jafari-Khouzani, Kourosh
    Paynabar, Kamran
    Hajighasemi, Fatemeh
    Rosen, Bruce
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (03) : 864 - 872
  • [9] Comparison of the effect of region-of-interest methods using gadoxetic acid-enhanced MR imaging with diffusion-weighted imaging on staging hepatic fibrosis
    Ying Ding
    Shengxiang Rao
    Li Yang
    Caizhong Chen
    Mengsu Zeng
    La radiologia medica, 2016, 121 : 821 - 827
  • [10] Comparison of the effect of region-of-interest methods using gadoxetic acid-enhanced MR imaging with diffusion-weighted imaging on staging hepatic fibrosis
    Ding, Ying
    Rao, Shengxiang
    Yang, Li
    Chen, Caizhong
    Zeng, Mengsu
    RADIOLOGIA MEDICA, 2016, 121 (11): : 821 - 827