Server Liquid Cooling with Chiller-less Data Center Design to Enable Significant Energy Savings

被引:0
|
作者
Iyengar, Madhusudan
David, Milnes
Parida, Pritish
Kamath, Vinod
Kochuparambil, Bejoy
Graybill, David
Schultz, Mark
Gaynes, Michael
Simons, Robert
Schmidt, Roger
Chainer, Timothy
机构
关键词
Data center; liquid cooling; energy efficiency;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper summarizes the concept design and hardware build efforts as part of a US Department of Energy cost shared grant, two year project (2010-2012) that was undertaken to develop highly energy efficient, warm liquid cooled servers for use in chiller-less data centers. Significant savings are expected in data center energy, refrigerant and make up water use. The technologies being developed include liquid cooling hardware for high volume servers, advanced thermal interface materials, and dry air heat exchanger (chiller-less with all year "econom izer") based facility level cooling systems that reject the Information Technology (IT) equipment heat load directly to the outside ambient air. Substantial effort has also been devoted towards exploring the use of high volume manufacturable components and cost optimized cooling designs that address high volume market design points. Demonstration hardware for server liquid cooling and data center economizer based cooling has been built and is operational for a 15 kW rack fully populated with liquid cooled servers. This design allows the use of up to 45 degrees C liquid coolant to the rack. Data collection has commenced to document the system thermal performance and energy usage using sophisticated instrumentation and data collection software methodologies. The anticipated benefits of such energy-centric configurations are significant energy savings at the data center level of as much as 30% and energy-proportional cooling in real time based on IT load and ambient air temperatures. The objective of this project is to reduce the cooling energy to 5% or less of a comparable typical air cooled chiller based total data center energy. Additional energy savings can be realized by reducing the IT power itself through reduced server fan power and potentially less leakage power due to lower device temperatures on average for most locations. This paper focuses on the server liquid cooling, the rack enclosure with heat exchanger cooling and liquid distribution, and the data center level cooling infrastructure. A sample of recently collected energy-efficiency data is also presented to provide experimental validation of the concept demonstrating cooling energy use to be less than 3.5% of the IT power for a hot summer day in New York.
引用
收藏
页码:212 / 223
页数:12
相关论文
共 27 条
  • [1] SYSTEM-LEVEL DESIGN FOR LIQUID COOLED CHILLER-LESS DATA CENTER
    Panda, Pritish R.
    Chainer, Timothy
    Iyengar, Madhusudan
    David, Milnes
    Schultz, Mark
    Gaynes, Michael
    Kamath, Vinod
    Kochuparambil, Bejoy
    Simons, Robert
    Schmidt, Roger
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 9, PTS A AND B, 2013, : 1127 - 1139
  • [2] Experimental Investigation of Water Cooled Server Microprocessors and Memory Devices in an Energy Efficient Chiller-less Data Center
    Parida, Pritish R.
    David, Milnes
    Iyengar, Madhusudan
    Schultz, Mark
    Gaynes, Michael
    Kamath, Vinod
    Kochuparambil, Bejoy
    Chainer, Timothy
    2012 28TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2012, : 224 - 231
  • [3] The Performance Impact of Integrating Water Storage Into a Chiller-Less Data Center Design
    Rose, Isaac
    Wemhoff, Aaron P.
    Fleischer, Amy S.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (02)
  • [4] Experimental and numerical dynamic investigation of an energy efficient liquid cooled chiller-less data center test facility
    Gao, Tianyi
    David, Milnes
    Geer, James
    Schmidt, Roger
    Sammakia, Bahgat
    ENERGY AND BUILDINGS, 2015, 91 : 83 - 96
  • [5] Impact of Operating Conditions on a Chiller-less Data Center Test Facility with Liquid Cooled Servers
    David, Milnes P.
    Iyengar, Madhusudan K.
    Parida, Pritish
    Simons, Robert E.
    Schultz, Mark
    Gaynes, Michael
    Schmidt, Roger
    Chainer, Timothy
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 562 - 573
  • [6] A Dynamic Model of Failure Scenarios of the Dry Cooler in a Liquid Cooled Chiller-Less Data Center
    Gao, Tianyi
    David, Milnes
    Geer, James
    Schmidt, Roger
    Sammakia, Bahgat
    2015 31ST ANNUAL SEMICONDUCTOR THERMAL MEASUREMENT, MODELING & MANAGEMENT SYMPOSIUM (SEMI-THERM), 2015, : 113 - 119
  • [7] Extreme Energy Efficiency using Water Cooled Servers Inside a Chiller-less Data Center
    Iyengar, Madhusudan
    David, Milnes
    Parida, Pritish
    Kamath, Vinod
    Kochuparambil, Bejoy
    Graybill, David
    Schultz, Mark
    Gaynes, Michael
    Simons, Robert
    Schmidt, Roger
    Chainer, Timothy
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 137 - 149
  • [8] Experimental Investigation of Direct Attach Microprocessors in a Liquid-Cooled Chiller-less Data Center
    Schultz, Mark
    Gaynes, Michael
    Parida, Pritish
    Chainer, Timothy
    2014 IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2014, : 729 - 735
  • [9] DYNAMICALLY CONTROLLED LONG DURATION OPERATION OF A HIGHLY ENERGY EFFICIENT CHILLER-LESS DATA CENTER TEST FACILITY
    David, Milnes R.
    Parida, Pritish R.
    Schultz, Mark D.
    Simons, Robert E.
    Gaynes, Michael
    Schmidt, Roger
    Chainer, Timothy J.
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,
  • [10] Experimental Characterization of an Energy Efficient Chiller-less Data Center Test Facility with Warm Water Cooled Servers
    David, Milnes P.
    Iyengar, Madhusudan
    Parida, Pritish
    Simons, Robert
    Schultz, Mark
    Gaynes, Michael
    Schmidt, Roger
    Chainer, Timothy
    2012 28TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2012, : 232 - 237