Tangential breast irradiation: a multi-centric intercomparison of dose using a mailed phantom and thermoluminescent dosimetry

被引:7
|
作者
Davis, JB [1 ]
Miltchev, V [1 ]
机构
[1] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
关键词
breast irradiation; treatment planning; phantom measurements; 3D planning system;
D O I
10.1016/S0167-8140(99)00086-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To measure the accuracy of radiation therapy of the breast planned with 2D and 3D algorithms. Materials and methods: The accuracy of radiation therapy of the breast with 2D and 3D algorithms was investigated as a national intercomparison using a semi-anatomical breast phantom. The dose was measured with thermoluminescent (TL) dosemeters. Results: The mean deviation of measured to planned dose at isocentre was -2.7%. The influence of some planning and irradiation factors is evaluated. Conclusion: The study demonstrates that beam energy and the use of CT have no marked influence on the accuracy of dose calculations, care has to be exercised when wedges are used and even with sophisticated 3D algorithms there is a systematic error in the dose received by the patient. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 27 条
  • [1] A Study on Contralateral Thermoluminescent Breast Dosimetry of Tangential Breast Irradiation Using 6 MV Linear Accelerator Beams
    Moreno, Dickerson
    Lopez, Fe Alexandra
    Santacera, Raquel Irene
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2160 - 2162
  • [2] Three-dimensional dose distribution of tangential breast irradiation: results of a multicentre phantom dosimetry study
    Delancy, G
    Beckham, W
    Veness, M
    Ahern, V
    Back, M
    Boyages, J
    Fox, C
    Graham, P
    Jacob, G
    Lonergan, D
    Morgan, G
    Pendlebury, S
    Yuile, P
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (01) : 61 - 68
  • [3] 3-DIMENSIONAL DOSE DISTRIBUTION OF TANGENTIAL BREAST TREATMENT - A NATIONAL DOSIMETRY INTERCOMPARISON
    VANBREE, NAM
    VANBATTUM, LJ
    HUIZENGA, H
    MIJNHEER, BJ
    RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 252 - 260
  • [4] INVIVO DOSIMETRY FOR TANGENTIAL BREAST IRRADIATION - ROLE OF THE EQUIPMENT IN THE ACCURACY OF DOSE DELIVERY
    LEUNENS, G
    VERSTRAETE, J
    VANDAM, J
    DUTREIX, A
    VANDERSCHUEREN, E
    RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 285 - 289
  • [5] Intraoperative electron beam intercomparison of 6 sites using mailed thermoluminescence dosimetry: Absolute dose and energy
    Dries, Wim
    Petoukhova, Anna
    Hertsens, Nicolas
    Stevens, Piet
    Jarbinet, Valerie
    Bimmel-Nagel, Cathryn Huibregtse
    Weterings, Jan
    van Wingerden, Ko
    Bauwens, Charlotte
    Vanreusel, Verdi
    Simon, Stephane
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 119
  • [6] QUALITY AUDIT OF MEGAVOLTAGE RADIOTHERAPY UNITS - INTERCOMPARISON OF DOSE AT A REFERENCE POINT USING A MAILED TL-DOSIMETRY SYSTEM
    DAVIS, B
    FAESSLER, P
    RADIOTHERAPY AND ONCOLOGY, 1993, 28 (01) : 79 - 81
  • [7] Evaluation of novel modified tangential irradiation technique for breast cancer patients using dose-volume histograms
    Takeda, A
    Shigematsu, N
    Ikeda, T
    Kawaguchi, O
    Kutsuki, S
    Ishibashi, R
    Kunieda, E
    Takeda, T
    Takemasa, K
    Ito, H
    Uno, T
    Jinno, H
    Kubo, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04): : 1280 - 1288
  • [8] Patient effective dose from sentinel lymph node lymphoscintigraphy in breast cancer: a study using a female humanoid phantom and thermoluminescent dosemeters
    Law, M
    Cheng, KC
    Wu, PM
    Ho, WY
    Chow, LWC
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (911): : 818 - 823
  • [9] Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom
    Schaeken, B.
    Lelie, S.
    Meijnders, P.
    Van den Weyngaert, D.
    Janssens, H.
    Verellen, D.
    MEDICAL PHYSICS, 2010, 37 (12) : 6292 - 6299
  • [10] 3D dose distributions in tangential field irradiation of the intact breast using wedges and individual compensators.
    Brown, LJ
    Redpath, AT
    Kunkler, IH
    BRITISH JOURNAL OF CANCER, 1998, 78 : 45 - 45