Validation of a Novel Approach for Dose Individualization in Pharmacotherapy Using Gabapentin in a Proof of Principles Study

被引:3
|
作者
Blau, Gary E. [1 ]
Orcun, Seza [2 ]
Lainez, Jose M. [1 ]
Reklaitis, Gintaras V. [1 ]
Suvannasankha, Attaya [3 ]
Fausel, Chris [3 ]
Anaissie, Elias J. [4 ]
机构
[1] Purdue Univ, Sch Chem Engn, W Lafayette, IN 47907 USA
[2] Seza Orcun Consulting Serv, W Lafayette, IN USA
[3] Indiana Univ, Simon Canc Ctr, Indianapolis, IN 46204 USA
[4] Univ Cincinnati, Sch Med, Cincinnati, OH USA
来源
PHARMACOTHERAPY | 2013年 / 33卷 / 07期
基金
美国国家科学基金会;
关键词
pharmacokinetics; dose individualization; risk management; gabapentin treatment; therapeutic drug monitoring;
D O I
10.1002/phar.1267
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Study ObjectiveTo demonstrate the premise of individualized dosing charts (IDCs) as a clinical-bedside decision-support tool to individualize dosage regimens for drugs in which the interpatient variability is controlled by the pharmacokinetic (PK) behavior of the patient, to calculate the optimal sampling schedule (OSS), which minimizes the number of blood samples per patient. The approach is illustrated with available PK data for gabapentin. DesignRetrospective proof of principles study using gabapentin PK data from a published clinical trial. PatientsNineteen subjects in a trial designed to uncover the importance of the genetic contributions to variability in gabapentin absorption, renal elimination, and transport; subjects were monitored for 36hours after administration of a single dose of gabapentin 400mg, and plasma concentrations were determined at 14 time points. Measurements and Main ResultsWhen the PK profiles were different between subjects, the IDCs are dramatically different from each other and from the IDC for an average patient representing the patient population. The dose amount and dosing interval must be adjusted to maximize the probability of staying within the target concentration range. An optimal sampling methodology based on the assumption-free Bayesian approach is used to distinguish the PK profile of an individual patient from the patient population. In the case of gabapentin, only two optimally selected test blood samples, at 1.5 and 6hours after administration of a single doses, were necessary. The average sensitivity and the average specificity of the OSS was 99% and 96%, respectively. ConclusionIDCs display the risk of a patient violating the target concentration range for any dosage regimen. They can be used as a clinical-bedside decision-support tool in a patient-physician partnership to decide on a dose amount and dosing interval that are medically acceptable while practical and convenient to ensure compliance. By using the assumption-free Bayesian approach and the OSS, the number of samples required from a new patient to individualize the dosage regimen can be reduced significantly while preserving high levels of sensitivity and specificity. Prospective studies are being planned to validate the encouraging results. This approach can be extended to any drug if PK data and a target concentration range are available for either therapeutic drug monitoring or target concentration intervention.
引用
收藏
页码:727 / 735
页数:9
相关论文
共 50 条
  • [1] A value-oriented approach to business process specialization: Principles, proof-of-concept, and validation
    Leshob, Abderrahmane
    Mili, Hafedh
    Gonzalez-Huerta, Javier
    Boubaker, Anis
    JOURNAL OF SYSTEMS AND SOFTWARE, 2017, 127 : 120 - 149
  • [2] Validation of a Novel Dose Calculation Approach for Heterogeneous Voxelized Phantoms in a Parallel Computation Environment Using Electron Dose Kernels for Radiotherapy
    Huang, M.
    Sjoden, G.
    Li, J.
    Al-Basheer, A.
    Bolch, W.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Memantine pharmacotherapy - A naturalistic study using a population pharmacokinetic approach
    Kornhuber, Johannes
    Kennepohl, Evelin M.
    Bleich, Stefan
    Wiltfang, Fens
    Kraus, Thomas
    Reulbach, Udo
    Meineke, Ingolf
    CLINICAL PHARMACOKINETICS, 2007, 46 (07) : 599 - 612
  • [4] Experimental Validation of a Novel Approach to Fast and Accurate Kilovoltage Dose Computation
    Poirier, Y.
    Tambasco, M.
    Kouznetsov, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] A Novel Shorthand Approach to Knee Bone Age Using MRI: A Validation and Reliability Study
    Meza, Blake C.
    LaValva, Scott M.
    Aoyama, Julien T.
    DeFrancesco, Christopher J.
    Striano, Brendan M.
    Carey, James L.
    Nguyen, Jie C.
    Ganley, Theodore J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [6] A Dosimetric Study of Inhomogeneous Dose Delivery: A Novel Approach to Dose Escalation
    Nickols, N. G.
    Agazaryan, N.
    King, C.
    Lee, P.
    Steinberg, M.
    Kupelian, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S905 - S905
  • [7] Transpedicular Approach on a Novel Spine Simulator: A Validation Study
    Fuerst, David
    Hollensteiner, Marianne
    Gabauer, Stefan
    Esterer, Benjamin
    Trieb, Klemens
    Eckstein, Felix
    Schrempf, Andreas
    JOURNAL OF SURGICAL EDUCATION, 2018, 75 (04) : 1127 - 1134
  • [8] A Novel Approach to Policy Design Using Process Design Principles
    Taeihagh, Araz
    Banares-Alcantara, Rene
    Wang, Zun
    10TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, 2009, 27 : 2049 - 2054
  • [9] Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
    Cook, Tessa S.
    Couch, Gregory
    Couch, Timothy J.
    Kim, Woojin
    Boonn, William W.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 657 - 662
  • [10] Using the Microsoft Kinect for Patient Size Estimation and Radiation Dose Normalization: Proof of Concept and Initial Validation
    Tessa S. Cook
    Gregory Couch
    Timothy J. Couch
    Woojin Kim
    William W. Boonn
    Journal of Digital Imaging, 2013, 26 : 657 - 662