Development of a programmed temperature vaporization-gas chromatography-tandem mass spectrometry method for polycyclic aromatic hydrocarbons analysis in biota samples at ultratrace levels

被引:26
|
作者
Fernandez-Gonzalez, V. [1 ]
Muniategui-Lorenzo, S. [1 ]
Lopez-Mahia, P. [1 ]
Prada-Rodriguez, D. [1 ]
机构
[1] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
关键词
GC-MS-MS; Polycyclic aromatic hydrocarbons; Ion trap tandem mass Spectrometry; Biota samples; Mussels;
D O I
10.1016/j.chroma.2008.08.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents the development of a programmed temperature vaporization-gas chromatography-tandem mass spectrometry (PTV-GC-MS-MS) method for the determination of PAHs in complex environmental matrices. This method aims at overcoming the current problems in detecting these compounds in matrices such as biota samples. When these matrices are extracted, great amounts of lipid compounds are co-extracted and can interfere with the analysis of PAHs, complicating their identification and quantification. The developed method significantly improves the detection and quantification limits, since PTV-GC-MS-MS can detect compounds at low-ppb level in complex matrices. The instrumental LODs and LOQs achieved lie between 1.04 and 26.9 ng l(-1) and 2.06 and 45.4 ng l(-1), respectively, and are lower than those calculated in the GC-MS-SIM mode. The LODs and LOQs of the method range between 1.9 and 3.6 ng kg(-1) and between 79 and 99 ng kg(-1), respectively. The validation of the method were made with a mussel reference material (SRM 2799). The applicability of the method to real mussel samples was also studied. Samples were extracted by means of microwave energy (with acetone:hexane 1:1, v/v) and the extracts were cleaned in a glass column with 22g of alumina. The usefulness of the MS-MS detection was verified. The obtained results were satisfactory, with good accuracy and precision. The proposed PTV-GC-MS-MS method was successfully applied to real mussel samples affected by the Prestige sinking off the Galician coast. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:136 / 145
页数:10
相关论文
共 50 条
  • [1] Determination of aromatic and polycyclic aromatic hydrocarbons in gasoline using programmed temperature vaporization-gas chromatography-mass spectrometry
    Perez Pavon, Jose Luis
    Sanchez, Miguel del Nogal
    Fernandez Laespada, Maria Esther
    Cordero, Bernardo Moreno
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 196 - 202
  • [2] Determination of Polycyclic Aromatic Hydrocarbons and Halogenated Polycyclic Aromatic Hydrocarbons in Vegetable by Gas Chromatography-Tandem Mass Spectrometry
    Wang Li
    Jin Fen
    Li Min-Jie
    Liu Yue
    Jiao Bi-Ning
    Shao Hua
    Jin Mao-Jun
    Wang Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (06) : 869 - 875
  • [3] Modular Method for the Determination of Polycyclic Aromatic Hydrocarbons in Spices and Dried Herbs by Gas Chromatography-Tandem Mass Spectrometry
    Szternfeld, Philippe
    Marchi, Jessica
    Malysheva, Svetlana V.
    Joly, Laure
    FOOD ANALYTICAL METHODS, 2019, 12 (10) : 2383 - 2391
  • [4] Determination of polycyclic aromatic hydrocarbons (PAHs) in cosmetic products by gas chromatography-tandem mass spectrometry
    Wang, Sheng-Wei
    Hsu, Kuo-Hsien
    Huang, Shou-Chieh
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    Cheng, Hwei-Fang
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2019, 27 (03) : 815 - 824
  • [5] Analysis of polycyclic aromatic hydrocarbons in cigarette samples using gel permeation chromatography clean-up by gas chromatography-tandem mass spectrometry
    Lian, Wenliu
    Ren, Fenglian
    Tang, Liyun
    Dong, Daozhu
    MICROCHEMICAL JOURNAL, 2016, 129 : 194 - 199
  • [6] Multivariate optimization of a microextraction by packed sorbent-programmed temperature vaporization-gas chromatography-tandem mass spectrometry method for organophosphate flame retardant analysis in environmental aqueous matrices
    Naccarato, Attilio
    Elliani, Rosangela
    Sindona, Giovanni
    Tagarelli, Antonio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (30) : 7105 - 7120
  • [7] Determination of oxygenated polycyclic aromatic hydrocarbons in atmospheric aerosol samples by liquid chromatography-tandem mass spectrometry
    Delhomme, Olivier
    Millet, Maurice
    Herckes, Pierre
    TALANTA, 2008, 74 (04) : 703 - 710
  • [8] Determination of selected polycyclic aromatic hydrocarbons and oxygenated polycyclic aromatic hydrocarbons in aerosol samples by high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry
    Lintelmann, J
    Fischer, K
    Karg, E
    Schröppel, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) : 508 - 519
  • [9] Determination of filbertone in spiked olive oil samples using headspace-programmed temperature vaporization-gas chromatography–mass spectrometry
    José Luis Pérez Pavón
    Miguel del Nogal Sánchez
    María Esther Fernández Laespada
    Bernardo Moreno Cordero
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1463 - 1470
  • [10] Development of an innovative and "green" stir bar sorptive extraction-thermal desorption-gas chromatography-tandem mass spectrometry method for quantification of polycyclic aromatic hydrocarbons in marine biota
    Lacroix, C.
    Le Cuff, N.
    Receveur, J.
    Moraga, D.
    Auffret, M.
    Guyomarch, J.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1349 : 1 - 10