Removal of humic substances with different apparent molecular sizes using Fenton's reagent

被引:5
|
作者
De Julio, Marcelo [1 ]
Di Bernardo, Luiz [2 ]
De Julio, Tatiane Sakamoto [3 ]
de Campos, Sandro Xavier [4 ]
Vieira, Eny Maria [5 ]
机构
[1] Aeronaut Inst Technol ITA, Civil Engn Div, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[2] Univ Sao Paulo EESC USP, Sao Carlos Sch Engn, Dept Hydraul & Sanitat, BR-13566590 Sao Carlos, SP, Brazil
[3] Univ Taubate UNITAU, Dept Civil Engn, BR-12020330 Taubate, SP, Brazil
[4] Ponta Grossa State Univ UEPG, Dept Chem, BR-84030900 Ponta Grossa, PR, Brazil
[5] Univ Sao Paulo IQSC USP, Sao Carlos Chem Inst, BR-13566590 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Coagulation; DAF; Drinking water; Fenton's reagent; Humic substances; Molecular size; NATURAL ORGANIC-MATTER; WATER TREATMENT; DRINKING-WATER; NOM; COAGULATION; ACID; DEGRADATION; WEIGHT; ALUM;
D O I
10.1080/19443994.2012.677495
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fenton's reagent was used as a coagulating agent in the treatment of water samples with high true color caused by humic substances (HS) extracted from peat. The effects of the apparent molecular size of HS on coagulation, flocculation, and flotation were studied. Four distinct water samples having the same true colors were prepared using HS with different molecular sizes obtained through ultrafiltration fractioning. Through optimization of the coagulant dosage and coagulation pH and the construction of coagulation diagrams for each water sample, it was verified that the sample with the smallest apparent molecular size of HS was the most difficult to treat, requiring higher coagulant (Fenton's reagent) dosages than samples prepared with larger HS molecular sizes. Furthermore, filtration experiments after dissolved air flotation were carried out to simulate conventional treatment. The most representative results in filtered water were: absorbance at 254 nm <= 0.016 cm(-1); apparent color <= 3 HU; and residual iron concentration < 0.005 mg L-1. The total organic carbon values of filtered water samples were also very low, always < 1.0 mg L-1.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [1] Influence of the apparent molecular size of humic substances on the efficiency of coagulation using Fenton's reagent
    de Julio, Marcelo
    de Julio, Tatiane S.
    Di Bernardo, Luiz
    ANAIS DA ACADEMIA BRASILEIRA DE CIENCIAS, 2013, 85 (02): : 833 - 847
  • [2] Color removal by coagulation, flocculation and sedimentation from water containing humic substances with different apparent molecular sizes
    Campos, Sandro X.
    de Azevedo, Eduardo Ribeiro
    Bonagamba, Tito J.
    Vieira, Eny M.
    Di Bernardo, Luiz
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2007, 56 (05): : 327 - 333
  • [3] Influence of the apparent molecular size of aquatic humic substances on colour removal by coagulation and filtration
    Rigobello, Eliane Sloboda
    Dantas, Angela Di Bernardo
    Di Bernardo, Luiz
    Vieira, Eny Maria
    ENVIRONMENTAL TECHNOLOGY, 2011, 32 (15) : 1767 - 1777
  • [4] Toxicity assessment of arsenic and cobalt in the presence of aquatic humic substances of different molecular sizes
    Watanabe, Claudia Hitomi
    Costa Monteiro, Adnivia Santos
    Jeunon Gontijo, Erik Sartori
    Lira, Vivian Silva
    Bueno, Carolina de Castro
    Kumar, Nirmal Tej
    Fracacio, Renata
    Rosa, Andre Henrique
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2017, 139 : 1 - 8
  • [5] Removal of humic substances from landfill leachate by Fenton oxidation and coagulation
    Wu, Yanyu
    Zhou, Shaoqi
    Qin, Fanghui
    Peng, Huaping
    Lai, Yanglan
    Lin, Liming
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2010, 88 (04) : 276 - 284
  • [6] EFFECTS OF DIFFERENT ORGANIC WASTE AMENDMENTS ON SOIL MICROAGGREGATES STABILITY AND MOLECULAR SIZES OF HUMIC SUBSTANCES
    PICCOLO, A
    MBAGWU, JSC
    PLANT AND SOIL, 1990, 123 (01) : 27 - 37
  • [7] Study on removal mechanisms on humic acid of drinking source water with Fenton reagent
    Li, Lei
    Han, Long
    WenChen
    Xue, Senjuan
    Wang, Wenjuan
    Xu, Yanhua
    MANUFACTURE ENGINEERING AND ENVIRONMENT ENGINEERING, VOLS 1 AND 2, 2014, 84 : 603 - 609
  • [8] Use of Fenton reagent combined with humic acids for the removal of PFOA from contaminated water
    Santos, Aurora
    Rodriguez, Sergio
    Pardo, Fernando
    Romero, Arturo
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 563 : 657 - 663
  • [9] Mechanism and kinetic of methyldopa removal by Fenton's reagent
    Tang, You-Min
    Guan, Bao-Hong
    Wu, Zhong-Biao
    Huanjing Kexue/Environmental Science, 2008, 29 (05): : 1271 - 1276
  • [10] Determination of the apparent rate constants of the degradation of humic substances by ozonation and modeling of the removal of humic substances from the aqueous solutions with neural network
    Oguz, Ensar
    Tortum, Ahmet
    Keskinler, Buelent
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (2-3) : 455 - 463