Signal-to-noise ratio of diffusion weighted magnetic resonance imaging: Estimation methods and in vivo application to spinal cord

被引:8
|
作者
Griffanti, Ludovica [1 ,2 ]
Baglio, Francesca [1 ]
Preti, Maria Giulia [1 ,2 ]
Cecconi, Pietro [3 ]
Rovaris, Marco [4 ]
Baselli, Giuseppe [2 ]
Lagana, Maria Marcella [1 ]
机构
[1] Fdn Don Carlo Gnocchi ONLUS, MR Res Lab, I-20148 Milan, Italy
[2] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
[3] Fdn Don Carlo Gnocchi ONLUS, Dept Radiol, I-20148 Milan, Italy
[4] Fdn Don Carlo Gnocchi ONLUS, Multiple Sclerosis Unit, I-20148 Milan, Italy
关键词
Signal-to-noise-ratio; Diffusion tensor imaging; Sequence optimization; Spinal cord; TENSOR TRACTOGRAPHY; MULTIPLE-SCLEROSIS; FRACTIONAL ANISOTROPY; MEAN DIFFUSIVITY; CERVICAL CORD; FIBER TRACTOGRAPHY; PYRAMIDAL TRACT; TRACKING; MS; DTI;
D O I
10.1016/j.bspc.2011.06.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diffusion tensor imaging (DTI) and tractographic reconstruction may be applied for in vivo clinical spinal cord studies. However, this structure represents a challenge to current acquisition and reconstruction strategies, due to its small size, motion artifacts, partial volume effects and low signal-to-noise-ratio (SNR). Aims of this work were to select the best approach for the estimate of SNR and to use it for spinal cord diffusion weighted (DW) sequence optimization. Seven methods for the estimate of SNR were compared on uniform phantom DW images, and the best performing approach (single ROI for signal and noise, difference of images-SNRdiff) was applied for the following in vivo sequence evaluations. Fifteen sequences with different parameters (voxel size, repetition (TR) and echo (TE) times) were compared according to SNR, resolution, fractional anisotropy (FA) and tractography performances on three healthy volunteers. In vivo optimization of DW sequences resulted in: axial sequence, with voxel size = 1.5 mm x 1.5 mm x 3.5 mm, TR = 3200 ms and TE = 89 ms, sagittal sequence with voxel size = 2.2 mm x 2.2 mm x 2 mm, TR = 3000 ms and TE = 84 ms. An objective method tested on phantom and a practical index for in vivo spinal cord DTI SNR estimation allowed to obtain axial and sagittal optimized sequences, providing excellent tractographic results, with acceptable acquisition times for in vivo clinical applications. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [1] Measuring the signal-to-noise ratio in magnetic resonance imaging: a caveat
    Erdogmus, D
    Larsson, EG
    Yan, R
    Principe, JC
    Fitzsimmons, JR
    SIGNAL PROCESSING, 2004, 84 (06) : 1035 - 1040
  • [2] Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images
    K. S. Sim
    M. A. Lai
    C. P. Tso
    C. C. Teo
    Journal of Medical Systems, 2011, 35 : 39 - 48
  • [3] Boosting magnetic resonance imaging signal-to-noise ratio using magnetic metamaterials
    Duan, Guangwu
    Zhao, Xiaoguang
    Anderson, Stephan William
    Zhang, Xin
    COMMUNICATIONS PHYSICS, 2019, 2 (1)
  • [4] Single Image Signal-to-Noise Ratio Estimation for Magnetic Resonance Images
    Sim, K. S.
    Lai, M. A.
    Tso, C. P.
    Teo, C. C.
    JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (01) : 39 - 48
  • [5] Boosting magnetic resonance imaging signal-to-noise ratio using magnetic metamaterials
    Guangwu Duan
    Xiaoguang Zhao
    Stephan William Anderson
    Xin Zhang
    Communications Physics, 2
  • [6] Diffusion-weighted magnetic resonance imaging of the spine and spinal cord
    Thurnher, Majda M.
    Bammer, Roland
    SEMINARS IN ROENTGENOLOGY, 2006, 41 (04) : 294 - 311
  • [7] Increase the Signal-to-Noise Ratio of Magnetic Resonance Imaging by a Vertical Coil Array
    Liang, Dandan
    Hui, Hon Tat
    Yeo, Tat Soon
    2012 IEEE ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2012, : 311 - 312
  • [8] Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
    Ahn, CB
    Song, YC
    Park, DJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (06) : 549 - 556
  • [9] Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
    Department of Electrical Engineering, Kwangwoon University, Taejon, Korea, Republic of
    不详
    IEEE Trans. Med. Imaging, 6 (549-556):
  • [10] The signal-to-noise ratio of the nuclear magnetic resonance experiment
    Hoult D.I.
    Richards R.E.
    Journal of Magnetic Resonance, 2011, 213 (02) : 329 - 343