Removal of boron from geothermal water by RO system-I-Effect of membrane configuration and applied pressure

被引:19
|
作者
Yavuz, Emre [1 ]
Guler, Enver [2 ]
Sert, Gokhan [3 ]
Arar, Ozgur [1 ]
Yuksel, Mithat [2 ]
Yuksel, Umran [1 ]
Kitis, Mehmet [4 ]
Kabay, Nalan [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
[2] Ege Univ, Fac Engn, Dept Chem Engn, TR-35100 Izmir, Turkey
[3] Ege Univ, Fac Fisheries, TR-35100 Izmir, Turkey
[4] Suleyman Demirel Univ, Dept Environm Engn, TR-32200 Isparta, Turkey
关键词
Boron; Desalination; Irrigation water; Geothermal water; Reverse osmosis; ION-EXCHANGE-RESINS; WASTE-WATER; POWER-PLANT; DESALINATION; RECOVERY; SEAWATER;
D O I
10.1016/j.desal.2012.07.026
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, a mini pilot scale reverse osmosis (RO) system containing two spiral wound FilmTech BW30-2540 membranes was installed at a geothermal area in Izmir, Turkey. The desalination and boron removal performances of this system were investigated. The effect of such parameters as operating pressure and the number of membranes employed during the operation on desalination performance of the system was investigated. The system performance was evaluated at 12 and 15 bar of operating pressures as a function of the number of membranes used. Desalination performance of brackish water reverse osmosis (BWRO) system was determined by the quality and quantity analyses of the product water. When the operating pressure was increased, a high permeate recovery, permeate flux and salt rejection were obtained with both single and double membrane configurations. The maximum boron rejection was 47% at 12 bar of applied pressure while it increased to 49% at 15 bar of applied pressure using a single membrane mode of operation. The lowest average boron concentration in the product water was 4.7 mg/L at 15 bar of applied pressure for a single membrane configuration. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [1] Removal of boron from geothermal water by RO system-II-effect of pH
    Yavuz, Emre
    Arar, Ozgur
    Yuksel, Mithat
    Yuksel, Umran
    Kabay, Nalan
    DESALINATION, 2013, 310 : 135 - 139
  • [2] Removal of boron from geothermal water by RO System-III-Utilization of SWRO system
    Yavuz, Emre
    Arar, Ozgur
    Yuksel, Umran
    Yuksel, Mithat
    Kabay, Nalan
    DESALINATION, 2013, 310 : 140 - 144
  • [3] Boron removal from geothermal water by air gap membrane distillation
    Ozbey-Unal, Bahar
    Imer, Derya Y.
    Keskinler, Bulent
    Koyuncu, Ismail
    DESALINATION, 2018, 433 : 141 - 150
  • [6] Removal of boron from geothermal water using hydrotalcite
    Wajima T.
    Toxicological and Environmental Chemistry, 2010, 92 (05): : 879 - 884
  • [7] Removal of boron from geothermal water by a novel boron selective resin
    Kabay, N. (nalan.kabay@ege.edu.tr), 1600, Elsevier B.V., Netherlands (310):
  • [8] An innovative integrated system for boron removal from geothermal water using RO process and ion exchange-ultrafiltration hybrid method
    Kabay, Nalan
    Koseoglu, Pelin
    Yavuz, Emre
    Yuksel, Umran
    Yuksel, Mithat
    DESALINATION, 2013, 316 : 1 - 7
  • [9] Removal of boron from geothermal water by a novel boron selective resin
    Santander, Paola
    Rivas, Bernabe L.
    Urbano, Bruno F.
    Ipek, Idil Yilmaz
    Ozkula, Gulsah
    Arda, Muserref
    Yuksel, Mithat
    Bryjak, Marek
    Kozlecki, Tomasz
    Kabay, Nalan
    DESALINATION, 2013, 310 : 102 - 108
  • [10] Boron removal from geothermal water using DOW chemical high separation BWRO membrane
    Tomaszewska, Barbara
    Bodzek, Michal
    Kmiecik, Ewa