Design and Analysis of Three Phase Four Wire Shunt Active Filter with Neural Network Controller for Different Loading Conditions

被引:0
|
作者
Karthikeyan, V. V. [1 ]
Thangavel, S. [2 ]
Sreedendu [1 ]
Sasikala, R. [1 ]
机构
[1] SNS Coll Engn, Coimbatore, Tamil Nadu, India
[2] KS Rangasamy Coll Technol, Thiruchangode, India
关键词
Active filter; Neural network; PI controller; Hysteresis current control;
D O I
10.1007/978-81-322-2119-7_100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Non-linear loads draw harmonic current and propagate them through the supply line. These current affect both the consumers and utility. To eliminate harmonics shunt active filters are widely used. In this paper three phase four wire shunt active filter is analyzed for the mitigation of power quality problem. Task of an active filter is to make the supply current waveform as close as possible to a sinusoid in phase with the supply voltage. Id and Iq control strategy is used to extract three phase reference current. Output of the PI controller tuned by neural network controller and result is compared. Design, simulation development and study of shunt active filter is accomplished using MATLAB Simulink power system tool box.
引用
收藏
页码:1027 / 1035
页数:9
相关论文
共 50 条
  • [1] Design and Analysis of Shunt Active Filter with Fuzzy Logic Controller Under Different Loading Conditions
    Sasikala, R.
    Sreedendu
    Karthikeyan, V. V.
    2014 INTERNATIONAL CONFERENCE ON GREEN COMPUTING COMMUNICATION AND ELECTRICAL ENGINEERING (ICGCCEE), 2014,
  • [2] Neural network controlled three-phase four-wire shunt active power filter
    Elmitwally, A
    Abdelkader, S
    El-Kateb, M
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2000, 147 (02) : 87 - 92
  • [3] Neural network PI pepetitive controller for three-phase three-wire shunt active power filter
    Center of Electrical and Electronic Technology, Shanghai Jiao Tong University, Shanghai 200240, China
    不详
    不详
    Dianli Xitong Baohu yu Kongzhi, 3 (78-84+89):
  • [4] THREE-PHASE FOUR-WIRE SHUNT ACTIVE FILTER BASED ON BACKSTEPPING CONTROLLER
    Ben Amar, Asma
    Zellouma, Laid
    Benchouia, Mohamed Toufik
    Mahni, Tidjani
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2019, 64 (04): : 397 - 402
  • [5] Neural network controlled three-phase three-wire shunt active power filter
    Zouidi, Abdelaziz
    Fnaiech, Farhat
    Al-Haddad, Kamal
    2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, : 5 - +
  • [6] Combined Direct Adaptive Controller for a Three-Phase Four-Wire Shunt Active Power Filter
    Sefanello, Marcio
    Pinheiro, Humberto
    Gruendling, Hilton A.
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 872 - 877
  • [7] A novel model-based controller for a three-phase four-wire shunt active filter
    Valdez, A. A.
    Escobar, G.
    Torres-Olguin, R. E.
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 2559 - +
  • [8] Performance Analysis of Three-phase Four-wire Shunt Active Power Filter
    Vanjani, Harsha
    Choudhury, U. K.
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON RELIABILTY, OPTIMIZATION, & INFORMATION TECHNOLOGY (ICROIT 2014), 2014, : 496 - 500
  • [9] Robust Repetitive Control Design for a Three-Phase Four Wire Shunt Active Power Filter
    Pandove, Gitanjali
    Singh, Mukhtiar
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (05) : 2810 - 2818
  • [10] Design and Performance of a Shunt Active Power Filter for Three-phase Four-wire System
    Wu, Diyun
    Che, Yanbo
    Cheng, K. W. E.
    2009 3RD INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS: ELECTRIC VEHICLE AND GREEN ENERGY, 2009, : 88 - 88