Development of MOS-FET dosimeters for use in high radiation fields

被引:6
|
作者
Kramberger, G. [1 ]
Ambrozic, K. [1 ]
Gurer, U. [2 ]
Hiti, B. [1 ]
Karacali, H. [2 ]
Mandic, I [1 ]
Yilmaz, E. [2 ,3 ]
Yilmaz, O. [2 ]
Zavrtanik, M. [1 ]
机构
[1] Jozef Stefan Inst, Jamova 39, SI-1000 Ljubljana, Slovenia
[2] Abant Izzet Baysal Univ, Nucl Radiat Detectors Applicat & Res Ctr, TR-14030 Bolu, Turkey
[3] Abant Izzet Baysal Univ, Phys Dept, TR-14030 Bolu, Turkey
关键词
Dosimeter; MOS-FET; Oxide charge; COMPUTATIONAL ANALYSIS;
D O I
10.1016/j.nima.2020.164283
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Several sets of MOS-FET dosimeters dedicated for use in high dose environments at particle physics experiments and nuclear reactors were produced by NURDAM. Various oxide thicknesses ranging from 40 nm to 800 nm were employed to study sensitivity and dynamic range of the dosimeters. The sensors were exposed to ionization doses up to almost 700 kGy of reactor gamma-rays in two different ways; several sets of sensors were exposed in steps to fixed doses and read out in-between, while one set was continuously measured during the irradiations. A calibrated ionization cell in combination with precise simulation of the radiation environment in the reactor was used to accurately determine the dose received by the sensors. The agreement between sets of samples irradiated in different irradiation channels, hence dose rates, and different readout schemes was found to be very good. The dependence of the threshold voltage on the received dose was characterized over the entire range of doses. Sensitivity, dynamic range, saturation and breakdown voltages of sensors were investigated. After the irradiations, isothermal annealing at various temperatures took place to determine the sensor response over the extended periods of time in low dose rate fields.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] PHOTORESPONSES OF MOS-FET
    OKAMOTO, K
    INOUE, S
    SOLID-STATE ELECTRONICS, 1973, 16 (06) : 657 - 662
  • [2] MOS-FET ANALYZER
    STORM, HF
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1970, IM19 (01) : 2 - &
  • [3] POWER MOS-FET
    TOMISAWA, Y
    KURAMOTO, T
    TANABE, H
    IZUMIDA, T
    TOSHIBA REVIEW, 1979, (124): : 23 - 26
  • [4] MOS-FET FABRICATION PROBLEMS
    KIM, MJ
    SOLID-STATE ELECTRONICS, 1969, 12 (07) : 557 - +
  • [5] A study on high-κ gate stack for MOS-FET
    Kundu, Soumik Kumar
    Karmakar, Samit
    Reza, Md. Samim
    Dutta, Arindam
    Taki, G. S.
    2015 INTERNATIONAL CONFERENCE AND WORKSHOP ON COMPUTING AND COMMUNICATION (IEMCON), 2015,
  • [6] A COMPUTATION OF HIGH-FREQUENCY NOISE QUANTITIES OF A MOS-FET
    KLAASSEN, FM
    PHILIPS RESEARCH REPORTS, 1969, 24 (06): : 559 - &
  • [7] SIZE AND HIGH-FIELD EFFECTS IN MOS-FET DEVICES
    PORJESZ, T
    ZSOLT, G
    KOVACS, G
    KARMAN, T
    ACTA PHYSICA HUNGARICA, 1987, 62 (01) : 7 - 9
  • [8] Experimental evaluation of MOS-FET snubber circuit
    Tezak, O
    Dolinar, D
    Milanovic, M
    IEEE REGION 8 EUROCON 2003, VOL A, PROCEEDINGS: COMPUTER AS A TOOL, 2003, : 146 - 150
  • [9] DC CHARACTERISTICS OF A MOS-FET WITH A VERTICAL CHANNEL
    PAVLOV, GP
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1984, 27 (11): : 76 - 78
  • [10] REQUIREMENTS FOR PARALLEL CONNECTED POWER MOS-FET
    LORENZ, L
    WISSMANN, G
    ETZ ARCHIV, 1986, 8 (01): : 23 - 30