Energy and comfort in contemporary open plan and traditional personal offices

被引:40
|
作者
Shahzad, Sally [1 ]
Brennan, John [1 ]
Theodossopoulos, Dimitris [1 ]
Hughes, Ben [2 ]
Calautit, John Kaiser [2 ]
机构
[1] Univ Edinburgh, Edinburgh Coll Art, Edinburgh Sch Architecture & Landscape Architectu, Edinburgh EH1 1JZ, Midlothian, Scotland
[2] Univ Sheffield, Sch Mech Engn, Sheffield S10 2TN, S Yorkshire, England
关键词
Thermal comfort; Energy; Individual control; Personal office; Open plan office; THERMAL COMFORT; OCCUPANT SATISFACTION; FIELD; BUILDINGS; SYSTEM; MODEL;
D O I
10.1016/j.apenergy.2016.02.100
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two office layouts with high and low levels of thermal control were compared, respectively traditional cellular and contemporary open plan offices. The traditional Norwegian practice provided every user with control over a window, blinds, door, and the ability to adjust heating and cooling. Occupants were expected to control their thermal environment to find their own comfort, while air conditioning was operating in the background to ensure the indoor air quality. In contrast, in the British open plan office, limited thermal control was provided through openable windows and blinds only for occupants seated around the perimeter of the building. Centrally operated displacement ventilation was the main thermal control system. Users' perception of thermal environment was recorded through survey questionnaires, empirical building performance through environmental measurements and thermal control through semi-structured interviews. The Norwegian office had 35% higher user satisfaction and 20% higher user comfort compared to the British open plan office. However, the energy consumption in the British practice was within the benchmark and much lower than the Norwegian office. Overall, a balance between thermal comfort and energy efficiency is required, as either extreme poses difficulties for the other. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1542 / 1555
页数:14
相关论文
共 50 条
  • [1] A field survey of visual comfort and lighting energy consumption in open plan offices
    Yun, Geun Young
    Kong, Hyo Joo
    Kim, Hyoin
    Kim, Jeong Tai
    ENERGY AND BUILDINGS, 2012, 46 : 146 - 151
  • [2] Acoustic comfort in open-plan offices: the role of employee characteristics
    Roskams, Michael
    Haynes, Barry
    Lee, Pyoung-Jik
    Park, Sang-Hee
    JOURNAL OF CORPORATE REAL ESTATE, 2019, 21 (03) : 254 - 270
  • [3] Thermal comfort in open plan offices in northern Italy: An adaptive approach
    Ricciardi, Paola
    Buratti, Cinzia
    BUILDING AND ENVIRONMENT, 2012, 56 : 314 - 320
  • [4] Comfort lightning and energy efficiency in open space offices
    Maia, I.
    Guedes, J.
    Santos Baptista, J.
    OCCUPATIONAL SAFETY AND HYGIENE IV, 2016, : 573 - 578
  • [5] Building-Related Symptoms, Energy, and Thermal Control in the Workplace: Personal and Open Plan Offices
    Shahzad, Sally S.
    Brennan, John
    Theodossopoulos, Dimitris
    Hughes, Ben
    Calautit, John Kaiser
    SUSTAINABILITY, 2016, 8 (04):
  • [6] Thermal Comfort and Adaptive Occupant Behaviour in Open Plan Offices in India and Lithuania
    Tuniki, Himanshu Patel
    Jurelionis, Andrius
    Rupp, Ricardo Forgiarini
    Valancius, Rokas
    Beko, Gabriel
    BUILDINGS, 2025, 15 (05)
  • [7] Effect of noise on comfort in open-plan offices: application of an assessment questionnaire
    Jegen, N. Perrin
    Chevret, P.
    ERGONOMICS, 2017, 60 (01) : 6 - 17
  • [8] The Effect of Seasons and Prevailing Environments on Adaptive Comfort Temperatures in Open Plan Offices
    Yun, Geun Young
    Kong, Hyo Joo
    Kim, Jeong Tai
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 41 - 47
  • [9] The feasibility of highly granular lighting control in open-plan offices: Exploring the comfort and energy saving potential
    de Bakker, Christel
    Aarts, Marielle
    Kort, Helianthe
    Rosemann, Alexander
    BUILDING AND ENVIRONMENT, 2018, 142 : 427 - 438
  • [10] ACOUSTICS IN OPEN PLAN OFFICES
    LEWITZ, JA
    CONSULTING ENGINEER, 1984, 62 (02): : 36 - 39