摘要
Objective: To compare surgical and endovascular stent graft (ESG) treatment of blunt thoracic aortic injury (BAI) in the emergency setting. Design and setting: Retrospective case control study in two surgical intensive care units of a university hospital. Patients: 30 patients who presented with BAI between 1995 and 2005: 17 treated surgically and 13 by ESG. The two groups were comparable for the severity of trauma and mean delay before treatment; the mean age was higher in the ESG group (46 +/- 18 vs. 35 +/- 15 years). Results: In the surgical group time spent in the operating theater was longer (310 +/- 130 vs. 140 +/- 48 min) and blood losses higher (2000 +/- 1300 vs. no significant bleeding); aortic clamping time was 48 +/- 20 min. The mortality rate was 15% with ESG (n = 2) and 23% with surgery (n = 4). Complications of the procedure were more frequent in the surgical group (1 vs. 7). In the ESG group there was one pulmonary embolism. In the surgical group there were three neurological complications, one acute aortic dissection, one perioperative rupture, one periprosthetic leak, and one septic shock. Two complications (postoperative aortic dissection and paraplegia) appeared in the same patient in the surgical group. Intensive care unit length of stay, duration of mechanical ventilation, and catecholamine support were similar in the two groups. Conclusions: Stent graft for emergency treatment of BAI is efficient and is associated with fewer complications than surgical treatment.
引用
收藏
页码:770 / 774
页数:5
相关论文
共 50 条
  • [1] Emergency endovascular stent graft repair for acute blunt thoracic aortic injury: a retrospective case control study
    Christophe Broux
    Frédéric Thony
    Olivier Chavanon
    Vincent Bach
    Rachid Hacini
    Christian Sengel
    Dominique Blin
    Pierre Lavagne
    Pierre Girardet
    Claude Jacquot
    Intensive Care Medicine, 2006, 32 : 770 - 774
  • [2] Emergency endovascular stent-graft repair for thoracic aortic injury
    Hanson, JA
    Brooks, DM
    Raman, JS
    MEDICAL JOURNAL OF AUSTRALIA, 2002, 176 (03) : 111 - 112
  • [3] ENDOVASCULAR AORTIC STENT GRAFT REPAIR FOR BLUNT TRAUMATIC THORACIC AORTIC TRANSECTION
    Saleh, Ayman
    Potemkowski, Antoni
    Abu-Zidan, Fikri M.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (10) : 847 - 848
  • [4] Blunt thoracic aortic injury: Open or stent graft repair?
    Yamane, Brett H.
    Tefera, Girma
    Hoch, J. R.
    Turnipseed, W. D.
    Acher, C. W.
    SURGERY, 2008, 144 (04) : 575 - 582
  • [5] Endovascular Stent graft repair of a thoracic aortic gunshot injury
    Baldwin, Z. K.
    Phillips, L. J.
    Bullard, M. K.
    Schneider, D. B.
    ANNALS OF VASCULAR SURGERY, 2008, 22 (05) : 692 - 696
  • [6] Immediate endovascular stent graft repair of acute thoracic aortic rupture due to blunt trauma
    Gan, JP
    Campbell, WA
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (01): : 154 - 157
  • [7] Endovascular repair of blunt thoracic aortic injury
    Stringel, Gustavo
    Xu, Min Li
    Erb, Markus
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2018, 30 : 52 - 55
  • [8] Effectiveness of Thoracic Endovascular Aortic Repair for Blunt Thoracic Aortic Injury
    Okadome, Jun
    Morishige, Noritsugu
    Sukehiro, Yuta
    Norio, Hirofumi
    Maetani, Kazuhide
    Yanase, Go
    Ito, Hiroyuki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 29 (03) : 133 - 140
  • [9] Intravascular ultrasound for stent graft sizing in emergency thoracic endovascular aortic repair
    Lortz, Julia
    Tsagakis, Konstantinos
    Rammos, Christos
    Rogmann, Kim
    Horacek, Michael
    Schlosser, Thomas
    Jakob, Heinz
    Rassaf, Tienush
    Janosi, Rolf Alexander
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B297 - B297
  • [10] Modified stent-graft for emergent repair of blunt thoracic aortic injury
    Battocchio, Piero
    Piazza, Michele
    Squizzato, Francesco
    Antonello, Michele
    JTCVS TECHNIQUES, 2020, 3 : 43 - 45