Developments on single and double stage GM type pulse tube cryorefrigerators

被引:0
|
作者
Poncet, JM [1 ]
Ravex, A [1 ]
Charles, I [1 ]
机构
[1] CEA, DRFMC, Serv Basses Temp, F-38054 Grenoble 9, France
来源
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Pulse tube (PT) cryocoolers with no moving parts in their cold ends are potentially able to replace conventional Gifford MacMahon (GM) cryocoolers for most applications. Over the past several years, CEA/SBT has undertaken basic research and prototype development of GM driven PT cryocoolers. Systematic studies have been carried out to characterize flow distribution and d.c. flow effects. Based on a good comprehension of these phenomena, several prototypes have been built and optimized for various customised applications. Their performance is presented in this paper.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [1] Developments on gm-type pulse tube cryorefrigerators with large cooling power
    Köttig, T
    Waldauf, A
    Thürk, M
    Seidel, P
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1445 - 1450
  • [2] Transient analysis of single stage GM type double inlet pulse tube cryocooler
    Gujarati, P. B.
    Desai, K. P.
    Naik, H. B.
    Atrey, M. D.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [3] Numerical and experimental investigations on a single stage GM-type double inlet pulse tube refrigerator for nitrogen liquefaction
    Panda, Debashis
    Kumar, Manoj
    Satapathy, Ashok K.
    Sarangi, Sunil K.
    Sahoo, Ranjit K.
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [4] Design of a 4K single-stage Stirling type pulse tube cooler precooled by a GM type pulse tube cooler
    Qiu, L. M.
    Li, Z. P.
    Gan, Z. H.
    Dai, L.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 313 - 316
  • [5] Studies on a single stage GM type pulse tube cryocooler using an indigenous helium compressor
    Kasthurirengan, S.
    Jacob, S.
    Karunanithi, R.
    Behera, Upendra
    Nadig, D. S.
    Bahuguni, Anand
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 253 - 256
  • [6] A single-stage GM-type pulse tube cryocooler operating at 10.6 K
    Gan, Z. H.
    Dong, W. Q.
    Qiu, L. M.
    Zhang, X. B.
    Sun, H.
    He, Y. L.
    Radebaugh, R.
    CRYOGENICS, 2009, 49 (05) : 198 - 201
  • [7] Experiment on a single-stage GM type pulse tube cryocooler near 20K
    Gan, Z. H.
    Liu, H. Z.
    Cheng, Z. Z.
    Qiu, L. M.
    Chen, G. B.
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 221 - 224
  • [8] Numerical Study of Single Stage GM-Type Pulse Tube Refrigerator for HTc-Superconductors
    Raju
    Ghosh, Suman
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [9] High efficiency, single-stage GM cryorefrigerators optimized for 20 to 40 K
    Wang, C
    Gifford, PE
    CRYOCOOLERS 11, 2001, : 387 - 392
  • [10] Development of 4 K pulse tube cryorefrigerators at cryomech
    Wang, C
    Gifford, PE
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 641 - 648