Intracranial 4D Flow MRI: Toward Individualized Assessment of Arteriovenous Malformation Hemodynamics and Treatment-Induced Changes

被引:77
|
作者
Ansari, S. A. [1 ,2 ]
Schnell, S. [1 ]
Carroll, T. [1 ,3 ]
Vakil, P. [1 ,3 ]
Hurley, M. C. [1 ,2 ]
Wu, C. [3 ]
Carr, J. [1 ]
Bendok, B. R. [1 ,2 ]
Batjer, H. [2 ]
Markl, M. [1 ,3 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Neurol Surg, Chicago, IL 60611 USA
[3] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
AMERICAN-STROKE-ASSOCIATION; HEALTH-CARE PROFESSIONALS; SPECIAL WRITING GROUP; BLOOD-FLOW; T; BRAIN; ANGIOGRAPHY; VISUALIZATION; ANEURYSMS; TIME;
D O I
10.3174/ajnr.A3537
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Arteriovenous malformations are an important etiology of hemorrhagic stroke. However, current imaging modalities and risk do not provide insights into individual AVM hemodynamics and its role in pathophysiology. The aims of this study are to determine whether intracranial 4D flow MR imaging can provide insights into arteriovenous malformation hemodynamics independent of the Spetzler-Martin grade and to report the changes in flow observed during staged embolization. MATERIALS AND METHODS: Intracranial 3D blood flow was assessed in 20 patients with AVM (age = 39 +/- 15 years, Spetzler-Martin grade ranging from 1-4) with the use of 4D flow MR imaging (temporal resolution = 45 ms, spatial resolution = [1.2-1.6mm](3)). AVM hemodynamics were visualized by means of time-integrated 3D pathlines depicting the AVM arterial feeding and venous draining patterns over the cardiac cycle. Analysis included the grading of feeding and draining velocities on a 3-point scale (0 = low <25 cm/s, 1 = medium <50 cm/s, 2 = high >50 cm/s). For 4 of 20 patients undergoing 4D flow MR imaging follow-up after staged embolization, peak velocities were quantified in arterial feeders, draining veins, the sagittal sinus, and contralateral arteries. RESULTS: In 50% of the cases with Spetzler-Martin grade >2, heterogeneous flow (velocity grade differences >1) was found across arteries and veins. Velocities in draining veins increased from Spetzler-Martin grade = 1 (grading = 0.5 +/- 0.6) to Spetzler-Martin grade >= 3 (1.1 +/- 0.6), whereas arterial velocities were similar (1.7 +/- 0.6 versus 1.5 +/- 0.6). In the postembolization subgroup of 4 patients, 4D flow MR imaging demonstrated successively more compact AVM and redistribution of velocities. Changes in arterial and venous velocities during treatment were highly different among individuals. CONCLUSIONS: Spetzler-Martin grade does not reflect differences in 3D AVM arterial and venous hemodynamics, and an individual assessment of AVM hemodynamics may be needed for improved lesion characterization. Four-dimensional flow MR imaging may have the potential to monitor and guide embolization treatment planning.
引用
收藏
页码:1922 / 1928
页数:7
相关论文
共 50 条
  • [1] 4D flow MRI for intracranial hemodynamics assessment in Alzheimer's disease
    Rivera-Rivera, Leonardo A.
    Turski, Patrick
    Johnson, Kevin M.
    Hoffman, Carson
    Berman, Sara E.
    Kilgas, Phillip
    Rowley, Howard A.
    Carlsson, Cynthia M.
    Johnson, Sterling C.
    Wieben, Oliver
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (10): : 1718 - 1730
  • [2] Automated Individualized Evaluation of Hemodynamics in Intracranial Atherosclerotic Disease With Dual-Venc 4D Flow MRI
    Ma, Yue
    Vali, Alireza
    Aristova, Maria
    Abdalla, Ramez
    Ansari, Sameer
    Prabhakaran, Shyam
    Ragin, Ann
    Schnell, Susanne
    STROKE, 2020, 51
  • [3] Hemodynamics in a giant intracranial aneurysm characterized by in vitro 4D flow MRI
    Amili, Omid
    Schiavazzi, Daniele
    Moen, Sean
    Jagadeesan, Bharathi
    Van de Moortele, Pierre-Francois
    Coletti, Filippo
    PLOS ONE, 2018, 13 (01):
  • [4] 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics
    Sekine, Tetsuro
    Takagi, Ryo
    Amano, Yasuo
    Murai, Yasuo
    Orita, Erika
    Matsumura, Yoshio
    Kumita, Shin-ichiro
    NEURORADIOLOGY, 2016, 58 (03) : 237 - 244
  • [5] 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics
    Tetsuro Sekine
    Ryo Takagi
    Yasuo Amano
    Yasuo Murai
    Erika Orita
    Yoshio Matsumura
    Shin-ichiro Kumita
    Neuroradiology, 2016, 58 : 237 - 244
  • [6] Early Hemodynamic Response Assessment of Stereotactic Radiosurgery for a Cerebral Arteriovenous Malformation Using 4D Flow MRI
    Li, C. Q.
    Hsiao, A.
    Hattangadi-Gluth, J.
    Handwerker, J.
    Farid, N.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (04) : 678 - 681
  • [7] Pressure Mapping and Hemodynamic Assessment of Intracranial Dural Sinuses and Dural Arteriovenous Fistulas with 4D Flow MRI
    Rivera-Rivera, L. A.
    Johnson, K. M.
    Turski, P. A.
    Wieben, O.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 485 - 487
  • [8] Intracranial aneurysm stiffness assessment using 4D Flow MRI
    Koizumi, Satoshi
    Kin, Taichi
    Sekine, Tetsuro
    Kiyofuji, Satoshi
    Umekawa, Motoyuki
    Saito, Nobuhito
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (06)
  • [9] Assessment of the Hemodynamics of Autogenous Arteriovenous Fistulas With 4D Phase Contrast-Based Flow Quantification MRI in Dialysis Patients
    Li Suqin
    Zhu Mingli
    Suo Shiteng
    Mi Honglan
    Zhang Lan
    Ni Qihong
    Lu Qing
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (04) : 1272 - 1280
  • [10] Editorial on "Quantification of Hemodynamics of Cerebral Arteriovenous Malformations After Stereotactic Radiosurgery Using 4D Flow MRI"
    Bergsland, Niels
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (06) : 1851 - 1852