Self-Expanding Stent and Delivery System for Aortic Valve Replacement

被引:7
|
作者
Mazilu, Dumitru [1 ]
Li, Ming [1 ]
Kocaturk, Ozgur [2 ]
Horvath, Keith A. [3 ]
机构
[1] NHLBI, Cardiothorac Surg Res Program, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiovasc Intervent Program, NIH, Bethesda, MD 20892 USA
[3] NHLBI, Cardiothorac Surg Res Program, NIH, Bethesda, MD 20892 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2012年 / 6卷 / 04期
基金
美国国家卫生研究院;
关键词
minimally invasive aortic valve replacement; self-expanding nitinol stents; shape memory materials; real-time MRI guidance; HIGH-RISK PATIENTS; IMPLANTATION; STENOSIS; PROSTHESIS;
D O I
10.1115/1.4007750
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, aortic valve replacement procedures require a sternotomy and use of cardiopulmonary bypass (CPB) to arrest the heart and provide a bloodless field in which to operate. A less invasive alternative to open heart surgery is transapical or transcatheter aortic valve replacement (TAVR), already emerging as a feasible treatment for patients with high surgical risk. The bioprosthetic valves are delivered via catheters using transarterial or transapical approaches and are implanted within diseased aortic valves. This paper reports the development of a new self-expanding stent for minimally invasive aortic valve replacement and its delivery device for the transapical approach under real-time magnetic resonance imaging (MRI) guidance. Made of nitinol, the new stent is designed to implant and embed a commercially available bioprosthetic aortic valve in aortic root. An MRI passive marker was affixed onto the stent and an MRI active marker to the delivery device. These capabilities were tested in ex vivo and in vivo experiments. Radial resistive force, chronic outward force, and the integrity of bioprosthesis on stent were measured through custom design dedicated test equipment. In vivo experimental evaluation was done using a porcine large animal model. Both ex vivo and in vivo experiment results indicate that the self-expanding stent provides adequate reinforcement of the bioprosthetic aortic valve and it is easier to implant the valve in the correct position. The orientation and positioning of the implanted valve is more precise and predictable with the help of the passive marker on stent and the active marker on delivery device. The new self-expanding nitinol stent was designed to exert a constant radial force and, therefore, a better fixation of the prosthesis in the aorta, which would result in better preservation of long-term heart function. The passive marker affixed on the stent and active marker embedded in the delivery devices helps to achieve precise orientation and positioning of the stent under MRI guidance. The design allows the stent to be retracted in the delivery device with a snaring catheter if necessary. Histopathology reports reveal that the stent is biocompatible and fully functional. All the stented bioprosthesis appeared to be properly seated in the aortic root. [DOI: 10.1115/1.4007750]
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Percutaneous aortic valve replacement with a self-expanding stent - First animal results
    Ferrari, M
    Hellige, G
    Schlosser, M
    Lang, K
    Frerichs, I
    Mueller, E
    Eisold, G
    Figulla, HR
    EUROPEAN HEART JOURNAL, 2002, 23 : 156 - 156
  • [2] Transcatheter Aortic Valve Replacement With a New Self-Expanding Transcatheter Heart Valve and Motorized Delivery System
    Binder, Ronald K.
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Wood, David A.
    Moss, Robert
    Leipsic, Jonathon
    Toggweiler, Stefan
    Freeman, Melanie
    Ostry, Avi J.
    Frerker, Christian
    Willson, Alexander B.
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 301 - 307
  • [3] Transcatheter Aortic Valve Replacement with a New Self-expanding Percutaneous Heart Valve and Motorized Delivery System
    Binder, Ronald
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Wood, David
    Moss, Robert
    Leipsic, Jonathon
    Toggweiler, Stefan
    Freeman, Melanie
    Willson, Alex
    Webb, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B233 - B233
  • [4] TRANSCATHETER AORTIC VALVE REPLACEMENT WITH A NEXT GENERATION SELF-EXPANDING PERCUTANEOUS HEART VALVE AND MOTORIZED DELIVERY SYSTEM
    Binder, R. K.
    Schaefer, U.
    Kuck, K.
    Wood, D. A.
    Toggweiler, S.
    Leipsic, J.
    Freeman, M.
    Willson, A. B.
    Webb, J. G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S360 - S360
  • [5] Self-Expanding Prostheses for Transcatheter Aortic Valve Replacement
    Kumar, Robert
    Latib, Azeem
    Colombo, Antonio
    Ruiz, Carlos E.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 596 - 609
  • [6] Optimal Oversizing in Transcatheter Aortic Valve Replacement with the Self-Expanding Evolut Valve System
    Mas-Peiro, Silvia
    Alperi, Alberto
    Avvedimento, Marisa
    Regueiro, Ander
    Avanzas, Pablo
    Angellotti, Domenico
    Esposito, Giovanni
    Vidal-Cales, Pablo
    Mohammadi, Siamak
    Farjat-Pasos, Julio
    Moris, Cesar
    Rodes-Cabau, Josep
    JOURNAL OF INVASIVE CARDIOLOGY, 2024, 36 (06):
  • [7] Self-expanding aortic valve stent-Material optimization
    Kumar, Gideon Praveen
    Mathew, Lazar
    COMPUTERS IN BIOLOGY AND MEDICINE, 2012, 42 (11) : 1060 - 1063
  • [8] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Kaul, Sanjay
    NEW ENGLAND JOURNAL OF MEDICINE, 2014, 371 (10): : 967 - 967
  • [9] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Adams, David H.
    Popma, Jeffrey J.
    Reardon, Michael J.
    Yakubov, Steven J.
    Coselli, Joseph S.
    Deeb, G. Michael
    Gleason, Thomas G.
    Buchbinder, Maurice
    Hermiller, James, Jr.
    Kleiman, Neal S.
    Chetcuti, Stan
    Heiser, John
    Merhi, William
    Zorn, George
    Tadros, Peter
    Robinson, Newell
    Petrossian, George
    Hughes, G. Chad
    Harrison, J. Kevin
    Conte, John
    Maini, Brijeshwar
    Mumtaz, Mubashir
    Chenoweth, Sharla
    Oh, Jae K.
    NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19): : 1790 - 1798
  • [10] Transarterial aortic valve replacement with a self expanding stent in pigs
    Ferrari, M
    Figulla, HR
    Schlosser, M
    Tenner, I
    Frerichs, I
    Damm, C
    Guyenot, V
    Werner, GS
    Hellige, G
    HEART, 2004, 90 (11) : 1326 - 1331