Ecological Study of Sick Building Syndrome among Healthcare Workers at Johor Primary Care Facilities

被引:2
|
作者
Salvaraji, Loganathan [1 ]
Shamsudin, Shamsul Bahari [1 ]
Avoi, Richard [1 ]
Saupin, Sahipudin [1 ]
Sai, Lee Kim [2 ]
Asan, Surinah Binti [3 ]
Toha, Haidar Rizal Bin [3 ]
Jeffree, Mohammad Saffree [1 ]
机构
[1] Univ Malaysia Sabah, Fac Med & Hlth Sci, Publ Hlth Med Dept, Jalan UMS, Kota Kinabalu 88400, Sabah, Malaysia
[2] Astar Lab Snd Bhd, 12-02 Jalan Permas 10-5, Masai 81750, Johor, Malaysia
[3] Malaysia Minist Hlth, Publ Hlth Div, Johor State Hlth Off, Johor Baharu 81200, Johor, Malaysia
关键词
sick building syndrome; indoor air quality; healthcare workers; health clinic; AIR-QUALITY; WATER;
D O I
10.3390/ijerph192417099
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: Persistent exposure to indoor hazards in a healthcare setting poses a risk of SBS. This study determines the prevalence of and risk factors for SBS among healthcare workers in health clinics. Methods: A cross-sectional study was conducted across four health clinics from February 2022 to May 2022. As part of the study, self-administered questionnaires were completed to determine symptoms related to SBS. An indoor air quality (IAQ) assessment was conducted four times daily for fifteen minutes at five areas in each clinic (laboratory, lobby, emergency room, pharmacy, and examination room). Result: Most of the areas illustrated poor air movement (<0.15 m/s), except for the laboratory. The total bacterial count (TBC) was above the standard limit in both the lobby and emergency room (>500 CFU/m(3)). The prevalence of SBS was 24.84% (77) among the healthcare workers at the health clinics. A significant association with SBS was noted for those working in the examination room (COR = 2.86; 95% CI = 1.31; 6.27) and those experiencing high temperature sometimes (COR = 0.25; 95% CI = 0.11; 0.55), varying temperature sometimes (COR = 0.31; 95% CI = 0.003), stuffy air sometimes (COR = 0.17; 95% CI = 0.005; 0.64), dry air sometimes (COR = 0.20; 95% CI = 0.007; 0.64), and dust sometimes (COR = 0.25; 95% CI = 0.11; 0.60) and everyday (COR = 0.34; 95% CI = 0.14; 0.81). Only healthcare workers in the examination room (AOR = 3.17; 95% CI = 1.35; 7.41) were found to have a significant risk of SBS when controlling for other variables. Conclusion: SBS is prevalent among healthcare workers at health clinics.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] SICK BUILDING SYNDROME AMONG HEALTHCARE WORKERS AND HEALTHCARE ASSOCIATES AT OBSERVED GENERAL HOSPITAL IN SLOVENIA
    Kalender-Smajlovic, Sedina
    Dovjak, Mateja
    Kukec, Andreja
    CENTRAL EUROPEAN JOURNAL OF PUBLIC HEALTH, 2021, 29 (01) : 28 - 37
  • [2] Working Conditions and Sick Building Syndrome among Health Care Workers in Vietnam
    Cuong Hoang Quoc
    Giang Vu Huong
    Hai Nguyen Duc
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (10)
  • [3] SICK BUILDING SYNDROME - A STUDY OF 4373 OFFICE WORKERS
    BURGE, S
    HEDGE, A
    WILSON, S
    BASS, JH
    ROBERTSON, A
    ANNALS OF OCCUPATIONAL HYGIENE, 1987, 31 (04): : 493 - 504
  • [4] Indoor pollution and sick building syndrome symptoms among workers in day-care centers
    Li, CS
    Hsu, CW
    Tai, ML
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1997, 52 (03): : 200 - 207
  • [5] Prevalence and risk factors of sick building syndrome among office workers
    Abdel-Hamid, Mona A.
    Hakim, Sally A.
    Elokda, Elsayed E.
    Mostafa, Nayera S.
    JOURNAL OF THE EGYPTIAN PUBLIC HEALTH ASSOCIATION, 2013, 88 (02): : 109 - 114
  • [6] Burnout syndrome among critical care healthcare workers
    Embriaco, Nathalie
    Papazian, Laurent
    Kentish-Barnes, Nancy
    Pochard, Frederic
    Azoulay, Elie
    CURRENT OPINION IN CRITICAL CARE, 2007, 13 (05) : 482 - 488
  • [7] Inpatient care of small and sick newborns in healthcare facilities
    S B Neogi
    R Khanna
    M Chauhan
    J Sharma
    G Gupta
    R Srivastava
    P K Prabhakar
    A Khera
    R Kumar
    S Zodpey
    V K Paul
    Journal of Perinatology, 2016, 36 : S18 - S23
  • [8] Inpatient care of small and sick newborns in healthcare facilities
    Neogi, S. B.
    Khanna, R.
    Chauhan, M.
    Sharma, J.
    Gupta, G.
    Srivastava, R.
    Prabhakar, P. K.
    Khera, A.
    Kumar, R.
    Zodpey, S.
    Paul, V. K.
    JOURNAL OF PERINATOLOGY, 2016, 36 : S18 - S23
  • [9] SICK BUILDING SYNDROME PLAGUES WORKERS, DWELLERS
    RIESENBERG, DE
    AREHARTTREICHEL, J
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1986, 255 (22): : 3063 - 3063
  • [10] Sick Building Syndrome: Indoor pollutants levels and prevalence of symptoms among workers of a sealed office building
    Boechat, JL
    Rios, JL
    Freitas, T
    Santos, CY
    Silva, JRLE
    Neto, FA
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3711 - 3715