ACOUSTIC CONDITIONS IN OPEN PLAN OFFICES - PILOT TEST RESULTS

被引:4
|
作者
Mikulski, Witold [1 ]
机构
[1] Natl Res Inst, Cent Inst Labour Protect, Dept Vibroacoust Hazards, Warsaw, Poland
关键词
acoustics of rooms; reverberation time; open space rooms; speech transmission index STI; open plan; open plan rooms for administrative work;
D O I
10.13075/mp.5893.00425
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Material and Methods: Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382-3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. Results: The reverberation time was 0.33-0.55 s (maximum permissible value in offices - 0.6 s; the criterion was met), sound absorption coefficient in relation to 1 m(2) of the room's plan was 0.77-1.58 m(2) (minimum permissible value - 1.1 m(2); 2 out of 6 rooms met the criterion), distraction distance was 8.5-14 m (maximum permissible value - 5 m; none of the rooms met the criterion), A-weighted sound pressure level of speech at a distance of 4 m was 43.8-54.7 dB (maximum permissible value - 48 dB; 2 out of 6 rooms met the criterion), spatial decay rate of the speech was 1.8-6.3 dB (minimum permissible value - 7 dB; none of the rooms met the criterion). Conclusions: Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions.
引用
收藏
页码:653 / 662
页数:10
相关论文
共 50 条
  • [1] Acoustic Issues in Open Plan Offices: A Typological Analysis
    Delle Macchie, Sara
    Secchi, Simone
    Cellai, Gianfranco
    BUILDINGS, 2018, 8 (11)
  • [2] Control of visual conditions for open-plan offices
    Leclercq, Maximilien
    Arnal, Etienne
    Anthierens, Cedric
    Bideaux, Eric
    MECHATRONICS, 2011, 21 (03) : 581 - 593
  • [3] Acoustic comfort in open-plan offices: the role of employee characteristics
    Roskams, Michael
    Haynes, Barry
    Lee, Pyoung-Jik
    Park, Sang-Hee
    JOURNAL OF CORPORATE REAL ESTATE, 2019, 21 (03) : 254 - 270
  • [4] ACOUSTICS IN OPEN PLAN OFFICES
    LEWITZ, JA
    CONSULTING ENGINEER, 1984, 62 (02): : 36 - 39
  • [5] Acoustics in open plan offices
    Lewitz, J.A.
    Consulting engineer Barrington, 1984, 62 (02): : 36 - 39
  • [6] Evaluation of the acoustic environments of open-plan offices in Korean public buildings
    Park, Sang Hee
    Shin, Hye-Kyung
    Lee, Seung-Min
    Kim, Kyoung Woo
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2023, 42 (01): : 42 - 49
  • [7] Empirical Study of Room Acoustic Conditions and Neurophysiologic Strain in Staff Working in Special Open-Plan Bank Offices
    Masoud Shafiee Motlagh
    Rostam Golmohammadi
    Mohsen Aliabadi
    Javad Faradmal
    Akram Ranjbar
    Acoustics Australia, 2018, 46 : 329 - 338
  • [8] Empirical Study of Room Acoustic Conditions and Neurophysiologic Strain in Staff Working in Special Open-Plan Bank Offices
    Motlagh, Masoud Shafiee
    Golmohammadi, Rostam
    Aliabadi, Mohsen
    Faradmal, Javad
    Ranjbar, Akram
    ACOUSTICS AUSTRALIA, 2018, 46 (03) : 329 - 338
  • [9] A comparative field study of indoor environmental quality in two types of open-plan offices: Open-plan administrative offices and open-plan research offices
    Lou, Huading
    Ou, Dayi
    BUILDING AND ENVIRONMENT, 2019, 148 : 394 - 404
  • [10] OPEN-PLAN OFFICES - BOJE,A
    LAWSON, BR
    ERGONOMICS, 1972, 15 (04) : 473 - 473