Effectiveness of Multimodal imaging for the Evaluation of Retinal oedema And new vesseLs in Diabetic retinopathy (EMERALD)

被引:8
|
作者
Lois, Noemi [1 ]
Cook, Jonathan [2 ]
Aldington, Stephen [3 ]
Waugh, Norman [4 ]
Mistry, Hema [4 ]
Sones, William [2 ]
McAuley, Danny [5 ]
Aslam, Tariq [6 ]
Bailey, Claire [7 ]
Chong, Victor [8 ]
Ghanchi, Faruque [9 ]
Scanlon, Peter [10 ]
Sivaprasad, Sobha [11 ]
Steel, David [12 ,13 ]
Styles, Caroline [14 ]
McNally, Christine [15 ]
Rice, Rachael [15 ]
Prior, Lindsay [16 ]
Azuara-Blanco, Augusto [17 ]
机构
[1] Queens Univ, Wellcome Wolfson Inst Expt Med, Ophthalmol, Belfast, Antrim, North Ireland
[2] Univ Oxford, NDORMS, Oxford, England
[3] Gloucester Hosp NHS Fdn Trust, Gloucester, England
[4] Univ Warwick, Div Hlth Sci, Warwick, England
[5] Queens Univ, Wellcome Wolfson Inst Expt Med, Belfast, Antrim, North Ireland
[6] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[7] Bristol Eye Hosp, Ophthalmol Dept, Bristol, Avon, England
[8] Royal Free Hosp NHS Fdn Trust, Ophthalmol, London, England
[9] Bradford Royal Infirm, Ophthalmol, Bradford, W Yorkshire, England
[10] Gloucestershire Hosp NHS Fdn Trust, Cheltenham, Glos, England
[11] Moorfields Eye Hosp, NIHR Moorfields Biomed Res Ctr, London, England
[12] Sunderland Eye Infirm, Sunderland, England
[13] Newcastle Univ, Inst Genet Med, Newcastle Upon Tyne, Tyne & Wear, England
[14] Queen Margaret Hosp, Ophthalmol, Dunfermline, Fife, Scotland
[15] Northern Ireland Clin Trials Unit, Belfast, Antrim, North Ireland
[16] Queens Univ Belfast, Belfast, Antrim, North Ireland
[17] Queens Univ, Ctr Publ Hlth, Belfast, Antrim, North Ireland
来源
BMJ OPEN | 2019年 / 9卷 / 06期
关键词
MACULAR EDEMA; RANIBIZUMAB; PREVALENCE; AFLIBERCEPT; LASER;
D O I
10.1136/bmjopen-2018-027795
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Diabetic macular oedema (DM0) and proliferative diabetic retinopathy (PDR) are the major causes of sight loss in people with diabetes. Due to the increased prevalence of diabetes, the workload related to these complications is increasing making it difficult for Hospital Eye Services (HSE) to meet demands. Methods and analysis Effectiveness of Multimodal imaging for the Evaluation of Retinal oedema And new vesseLs in Diabetic retinopathy (EMERALD) is a prospective, case-referent, cross-sectional diagnostic study. It aims at determining the diagnostic performance, cost-effectiveness and acceptability of a new form of surveillance for people with stable DM0 and/or PDR, which entails multimodal imaging and image review by an ophthalmic grader, using the current standard of care (evaluation of patients in clinic by an ophthalmologist) as the reference standard. If safe, cost-effective and acceptable, this pathway could help HES by freeing ophthalmologist time. The primary outcome of EMERALD is sensitivity of the new surveillance pathway in detecting active DMO/PDR. Secondary outcomes include specificity, agreement between new and the standard care pathway, positive and negative likelihood ratios, cost-effectiveness, acceptability, proportion of patients requiring subsequent full clinical assessment, unable to undergo imaging, with inadequate quality images or indeterminate findings. Ethics and dissemination Ethical approval was obtained for this study from the Office for Research Ethics Committees Northern Ireland (reference 17/N1/0124). Study results will be published as a Health Technology Assessment monograph, in peer-reviewed national and international journals and presented at national/ international conferences and to patient groups.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Multimodal imaging of diabetic retinopathy
    Khoi Tran
    Pakzad-Vaezi, Kaivon
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (06) : 566 - 575
  • [2] Telemedicine and Retinal Imaging for Improving Diabetic Retinopathy Evaluation
    Garg, Seema
    Jani, Pooja D.
    Kshirsagar, Abhijit V.
    King, Bradley
    Chaum, Edward
    ARCHIVES OF INTERNAL MEDICINE, 2012, 172 (21) : 1677 - 1678
  • [3] Diameter Changes of Retinal Vessels in Diabetic Retinopathy
    Toke Bek
    Current Diabetes Reports, 2017, 17
  • [4] Retinal Blood Vessels Segmentation of Diabetic Retinopathy
    Alaguselvi, R.
    Murugan, Kalpana
    2021 IEEE INTERNATIONAL CONFERENCE ON MOBILE NETWORKS AND WIRELESS COMMUNICATIONS (ICMNWC), 2021,
  • [5] Diameter Changes of Retinal Vessels in Diabetic Retinopathy
    Bek, Toke
    CURRENT DIABETES REPORTS, 2017, 17 (10)
  • [6] Multimodal imaging of disorganization of retinal layers and visual function impairment in Diabetic Retinopathy
    Vujosevic, Stela
    Alovisi, Camilla
    Piccoli, Gabriele
    Brambilla, Marco
    Marenzi, Elisa
    Torti, Emanuele
    Leporati, Francesco
    Luzi, Livio
    Nucci, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [7] Evaluation of a New Model of Care for People with Complications of Diabetic Retinopathy The EMERALD Study
    Lois, Noemi
    Cook, Jonathan A.
    Wang, Ariel
    Aldington, Stephen
    Mistry, Hema
    Maredza, Mandy
    McAuley, Danny
    Aslam, Tariq
    Bailey, Clare
    Chong, Victor
    Ganchi, Faruque
    Scanlon, Peter
    Sivaprasad, Sobha
    Steel, David H.
    Styles, Caroline
    Azuara-Blanco, Augusto
    Prior, Lindsay
    Waugh, Norman
    OPHTHALMOLOGY, 2021, 128 (04) : 561 - 573
  • [8] REDISCOVERING THE CLINICAL ROLE OF RETINAL MICROANEURYSMS IN DIABETIC RETINOPATHY: A QUANTITATIVE MULTIMODAL RETINAL IMAGING APPROACH.
    Arrigo, A.
    Aragona, E. A.
    Parodi, M. B. P. Battaglia
    Bandello, F. B.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (01) : 11 - 11
  • [9] Cost-effectiveness analysis of retinal imaging devices for diabetic retinopathy screening
    Bayani, Diana Beatriz Samson
    Reyes, Christelle Joy
    Sun, Jennifer K.
    Peto, Tunde
    Silva, Paolo Antonio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Evaluation and comparison of retinal blood vessels extraction using edge detectors in diabetic retinopathy
    Sarangi, Sunita
    Sabut, Sukant Kumar
    Majhi, Diptimayee
    INTERNATIONAL JOURNAL OF SIGNAL AND IMAGING SYSTEMS ENGINEERING, 2016, 9 (03) : 174 - 183