A Novel Calibration Method for Active Interferometer-Based VNAs

被引:4
|
作者
Mubarak, F. A. [1 ]
Romano, R. [2 ]
Rietveld, G. [1 ]
Spirito, M. [3 ]
机构
[1] Natl Metrol Inst Netherlands VSL, Dept Res & Dev, NL-2629 JA Delft, Netherlands
[2] Vertigo Technol BV, NL-2629 JA Delft, Netherlands
[3] Delft Univ Technol TUD, Elect Engn Dept, NL-2629 JA Delft, Netherlands
关键词
Calibration; extreme impedance measurement; impedance mismatch; measurement; microwave interferometry; nanoelectronics; nanostructures; noise; traceability; vector network analyzer (VNA);
D O I
10.1109/LMWC.2020.3006701
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The addition of RF interferometers to vector network analyzer (VNA) test benches has allowed for realization of low-noise high-frequency measurements of extreme impedance devices. However, when employing correction techniques such as the short-open-load method, the RF response of the interferometer hardware introduces measurement inaccuracies due to unwanted load-dependent inconsistencies. This letter presents a novel VNA calibration method that enables both low-noise and accurate small-signal characterization of highly mismatched devices. The proposed solution is experimentally validated in the 10-18-GHz band, confirming a 23-fold improvement in measurement resolution with absolute accuracy across the entire Gamma range of the VNA. The accuracy of the new calibration process is verified via comparison with traceable reference standards supported by state-of-the-art uncertainties.
引用
收藏
页码:829 / 832
页数:4
相关论文
共 50 条
  • [1] A Michelson interferometer-based method for measuring the angle of rotation
    Foo, C
    Madan, G
    Lai, T
    Wee, M
    Fu, Y
    Shang, HM
    SEVENTH INTERNATIONAL CONFERENCE ON EDUCATION AND TRAINING IN OPTICS AND PHOTONICS, 2002, 4588 : 320 - 325
  • [2] Interferometer-based position feedback
    不详
    MANUFACTURING ENGINEERING, 2003, 130 (04): : 32 - +
  • [3] Interferometer-based adaptive optical system
    Soloviev, O
    Vdovin, G
    ADAPTIVE OPTICS FOR INDUSTRY AND MEDICINE, PROCEEDINGS, 2005, 102 : 91 - 99
  • [4] INTERFEROMETER-BASED TRANSPORTABLE MEASURING EQUIPMENT
    CRABTREE, JJ
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1981, 3 (03): : 145 - 147
  • [5] Noise Behavior and Implementation of Interferometer-Based Broadband VNA
    Mubarak, Faisal Ali
    Romano, Rafaelle
    Galatro, Luca
    Mascolo, Vincenzo
    Rietveld, Gert
    Spirito, Marco
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2019, 67 (01) : 249 - 260
  • [6] Interferometer-Based Microwave Microscopy Operating in Transmission Mode
    Haddadi, Kamel
    Lasri, Tuami
    IEEE SENSORS JOURNAL, 2014, 14 (07) : 2226 - 2227
  • [7] Surface micromachined interferometer-based optical reading technique
    Christenson, GL
    Tran, ATTD
    Miller, SA
    Haronian, D
    Lo, YH
    MacDonald, NC
    APPLIED PHYSICS LETTERS, 1996, 69 (22) : 3324 - 3326
  • [8] Performance comparison of Michelson interferometer-based interleaver designs
    Cheng, Chi-Hao
    Wang, Shuping
    OPTICAL ENGINEERING, 2009, 48 (12)
  • [9] A Review of Sensitivity Enhancement in Interferometer-Based Fiber Sensors
    Wen, Zengrun
    Guan, Ziqing
    Dong, Jingru
    Li, Hongxin
    Cai, Yangjian
    Gao, Song
    SENSORS, 2022, 22 (07)
  • [10] Birefringent interferometer-based strain sensor with temperature insensitivity
    Kwon, Oh-Jang
    Kim, Hyun-Joo
    Chu, Suho
    Kim, Min-Seok
    Lee, Sang Bae
    Chung, Youngjoo
    Han, Young-Geun
    2009 14TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC 2009), 2009, : 127 - +