Efficacy of atrioventricular sequential pacing and diastolic mitral regurgitation in patients with intrinsic atrioventricular conduction

被引:12
|
作者
Ishikawa, T [1 ]
Sumita, S [1 ]
Kimura, K [1 ]
Kikuchi, M [1 ]
Kosuge, M [1 ]
Nakagawa, T [1 ]
Matsushita, K [1 ]
Usui, T [1 ]
Umemura, S [1 ]
机构
[1] Yokohama City Univ, Sch Med, Dept Internal Med 2, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
来源
关键词
DDD pacemaker; diastolic mitral regurgitation; echocardiography; PQ interval; transmitral flow;
D O I
10.1253/jcj.64.579
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
The efficacy of a short atrioventricular (AV) delay in patients with dilated cardiomyopathy has been reported, but there are deleterious effects of right ventricular pacing. Diastolic mitral regurgitation (MR) is observed in patients with elevated left ventricular end-diastolic pressure and can be induced by prolonging the AV delay in patients with DDD pacemakers. The critical PQ interval that induces diastolic MR may represent the upper limit of the optimal PQ interval. The efficacy of AV sequential pacing and diastolic MR were studied in Il patients (68.3+/-13.7 (SD) years old) with intrinsic AV conduction and with implanted DDD pacemakers. Cardiac output (CO) and pulmonary capillary wedge pressure (PCWP) were measured by Swan-Ganz catheter and transmitral flow was I recorded by pulsed Doppler echocardiography. AV delay was prolonged stepwise by 25ms starting from 65 ms. pacing rate was fixed at 70-80beats/min. In 6 of the 11 patients, diastolic MR was observed under atrial pacing and the critical PQ interval for the appearance of diastolic MR was 0,22+/-0.04s. CO was increased from 3.8+/-0.8 to 4.3+/-0.9 L/min (p<0.05) and PCWP was decreased from 7.5+/-2.8 to 5.5+/-1.6 mmHg (p<0.05) by shortening the AV delay till the diastolic MR disappeared, On the other hand, in 5 of the 11 patients, diastolic MR was not observed, and CO (4.2+/-0.5 to 4.3+/-0.5 L/min, ns) and PCWP (5.8+/-4.6 to 5.4+/-3.9 mmHg, ns) were not improved by AV sequential pacing. In conclusion, cardiac function may be improved by AV sequential pacing and setting the AV delay under the critical PQ interval for the appearance of diastolic MR when the diastolic MR is observed. However, AV sequential pacing may be either ineffective or even deleterious for patients in whom diastolic MR is not observed.
引用
收藏
页码:579 / 582
页数:4
相关论文
共 50 条
  • [1] EFFECT OF ATRIOVENTRICULAR SEQUENTIAL PACING IN PATIENTS WITH NO VENTRICULOATRIAL CONDUCTION
    MAHMUD, R
    DENKER, S
    LEHMANN, MH
    AKHTAR, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (02) : 273 - 277
  • [2] MITRAL REGURGITATION DURING ATRIOVENTRICULAR AND VENTRICULOATRIAL PACING
    REYNOLDS, DW
    OLSON, E
    BUROW, R
    THADANI, U
    LAZZARA, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 463 - 463
  • [3] DIASTOLIC MITRAL REGURGITATION IN ATRIOVENTRICULAR-BLOCK
    KORYTNIKOV, KI
    KLINICHESKAYA MEDITSINA, 1991, 69 (02): : 41 - 43
  • [4] DIASTOLIC MITRAL REGURGITATION IN PATIENTS WITH ATRIOVENTRICULAR-CONDUCTION ABNORMALITIES - A COMMON FINDING BY DOPPLER ECHOCARDIOGRAPHY
    PANIDIS, IP
    ROSS, J
    MUNLEY, B
    NESTICO, P
    MINTZ, GS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) : 768 - 774
  • [5] DOPPLER DETECTION AND QUANTITATION OF MITRAL REGURGITATION DURING VENTRICULAR AND ATRIOVENTRICULAR SEQUENTIAL PACING
    ZUGIBE, FT
    NANDA, NC
    AKIYAMA, T
    BAROLD, SS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 508 - 508
  • [6] FACILITATION OF RETROGRADE CONDUCTION WITH ATRIOVENTRICULAR SEQUENTIAL PACING
    MAHMUD, R
    LEHMANN, M
    ESTRADA, A
    SHENASA, M
    DENKER, S
    SARWAR, M
    AKHTAR, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (02) : 674 - 674
  • [7] Diastolic Mitral Regurgitation in 2:1 Atrioventricular Block
    Margulescu, Andrei D.
    Vinereanu, Dragos
    Cinteza, Mircea
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (02): : 228 - 229
  • [8] Diastolic atrioventricular regurgitation
    Bouzas-Mosquera, Alberto
    Garcia-Campos, Ana
    Alvarez-Garcia, Nemesio
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (11) : 797 - 798
  • [9] Atrioventricular sequential pacing causing haemodynamically significant mitral regurgitation immediately following cardiopulmonary bypass
    Hofmann, JP
    Malik, A
    Papadimos, T
    Peachman, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (07) : 619 - 621
  • [10] Diastolic Mitral Regurgitation in 2:1 Atrioventricular Block: Insight of the Diastolic Pressure
    Kocabay, Gonenc
    Peluso, Diletta
    Muraru, Denisa
    Iliceto, Sabino
    Badano, Luigi P.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (02): : E51 - E52