Going through the Mesh: Argon Plasma Trimming of a Metal Biliary Stent

被引:0
|
作者
Azevedo, Richard [1 ,2 ]
Libanio, Diogo [1 ]
Bastos, Pedro [1 ]
Ribeiro, Mario Dinis [1 ]
Brandao, Catarina [1 ]
机构
[1] Inst Portugues Oncol Porto Francisco Gentil, Gastroenterol Dept, Porto, Portugal
[2] Amato Lusitano Hosp, Gastroenterol Dept, Ave Pedro Alvares Cabral, PT-6000085 Castelo Branco, Portugal
关键词
Biliary metal stent; Adverse event; Migration; Argon plasma coagulation; Trimming;
D O I
10.1159/000493352
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
引用
收藏
页码:295 / 297
页数:3
相关论文
共 50 条
  • [1] Trimming a Metallic Biliary Stent Using an Argon Plasma Coagulator
    Rungsun Rerknimitr
    Pisit Naprasert
    Pradermchai Kongkam
    Pinit Kullavanijaya
    CardioVascular and Interventional Radiology, 2007, 30 : 534 - 536
  • [2] Trimming a metallic biliary stent using an argon plasma coagulator
    Rerknimitr, Rungsun
    Naprasert, Pisit
    Kongkam, Pradermchai
    Kullavanijaya, Pinit
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (03) : 534 - 536
  • [3] Usefulness of a circumferential argon plasma coagulation probe in trimming a dislocated distal biliary metal stent
    Yokode, Masataka
    Matsumori, Tomoaki
    Uza, Norimitsu
    Kuwada, Takeshi
    Shiokawa, Masahiro
    Maruno, Takahisa
    Seno, Hiroshi
    ENDOSCOPY, 2022, 54 : E802 - E803
  • [4] Reintervention using argon plasma coagulation trimming of a biliary metal stent under peroral direct cholangioscopy guidance
    Mitsuyama, Toshiyuki
    Ito, Takashi
    Shimatani, Masaaki
    DIGESTIVE ENDOSCOPY, 2020, 32 (05) : E100 - E101
  • [5] Trimming a covered metal stent during hepaticogastrostomy by using argon plasma coagulation
    Hamada, Tsuyoshi
    Nakai, Yousuke
    Isayama, Hiroyuki
    Saito, Kei
    Kogure, Hirofumi
    Sasaki, Takashi
    Yamamoto, Natsuyo
    Hirano, Kenji
    Tada, Minoru
    Koike, Kazuhiko
    GASTROINTESTINAL ENDOSCOPY, 2013, 78 (06) : 817 - 817
  • [6] Trimming of a migrated metal stent for malignant colonic stricture using argon plasma coagulation
    Rao, Kiran Venkat
    Beri, Gagan Deep
    Wang, Weizheng William
    WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2010, 2 (02): : 75 - 76
  • [7] Endoscopic placement of a biliary expandable metal stent through the mesh wall of a duodenal stent
    Novacek, G
    Pötzi, R
    Kornek, G
    Häfner, M
    Schöfl, R
    Gangl, A
    Püspök, A
    ENDOSCOPY, 2003, 35 (11) : 982 - 983
  • [8] Trimming of migrated metal Stent for malignant colonic stricture using argon plasma coagulation (APC)
    Rao, Kiran V.
    Beri, Gagan D.
    Wang, Weizheng
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S521 - S521
  • [9] Endoscopic argon plasma trimming of biliary and gastrointestinal metallic stents
    Vanbiervliet, G
    Piche, T
    Caroli-Bosc, FX
    Dumas, R
    Peten, EP
    Huet, PM
    Tran, A
    Demarquay, JF
    ENDOSCOPY, 2005, 37 (05) : 434 - 438
  • [10] Endoscopic trimming of distally migrated biliary self expanding metal stents using argon plasma coagulation
    Lazaro, Josef Carlo
    Mokamad, Jehan Kashmira
    Lim, Caroline
    Cala, Katherine
    Ong, Evan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 110 - 110