A Novel Immunoassay for the Quantization of CYFRA 21-1 in Human Serum

被引:23
|
作者
He, An [1 ]
Liu, Tian-Cai [1 ]
Dong, Zhi-Ning [1 ]
Ren, Zhi-Qi [1 ]
Hou, Jing-Yuan [1 ]
Li, Ming [1 ]
Wu, Ying-Song [1 ]
机构
[1] Southern Med Univ, Sch Biotechnol, Inst Antibody Engn, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金; 国家教育部博士点专项基金资助;
关键词
cytokeratin fragments; CYFRA; 21-1; AlphaLISA; homogeneous immunoassays; singlet oxygen; SQUAMOUS-CELL CARCINOMA; NEURON-SPECIFIC ENOLASE; OXYGEN CHANNELING IMMUNOASSAY; CYTOKERATIN; 19; FRAGMENTS; CARCINOEMBRYONIC ANTIGEN; LUNG-CANCER; PLEURAL FLUID; TUMOR-MARKERS; UTILITY; DIAGNOSIS;
D O I
10.1002/jcla.21597
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Cytokeratin 19 fragment antigen (CYFRA 21-1) is used to diagnose and monitor neoplasms. However, the main disadvantages of the currently available CYFRA 21-1 assays include heterogenous technology, being time-consuming, and having low through-put with low insensitivity. This study investigated the use of amplified luminescent proximity homogeneous immunoassay (AlphaLISA) for the quantization of CYFRA 21-1 in human serum. Methods: The AlphaLISA kit was developed based on AlphaScreen detection technology with two different anti-CYFRA 21-1 monoclonal antibodies. One was coated on AlphaLISA acceptor beads and the other was biotinylated. Donor beads were coated with streptavidin. The test conditions were optimized and analytical performance was studied. Results: The measurement range of AlphaLISA CYFRA 21-1 kit was 0.08-500 ng/ml. Assay detection limit was 0.08 ng/ml. The intra- and interassay coefficients of variation were 3.00-9.00% and 4.00-10.00%, respectively. There was no cross-reaction to alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), cancer antigen 19-9 (CA19-9), cytokeratins 8 (CK8), and cytokeratins 18 (CK18). The correlation coefficient of blood samples involved was 0.974 between CYFRA 21-1-AlphaLISA assay and a commercial electrochemiluminescence immunoassay (ECLIA) CYFRA 21-1 kit (Roche). Conclusions: The AlphaLISA CYFRA 21-1 kit developed in this study had favorable performance characteristics for clinical application with acceptable analytical sensitivity, specificity, and accuracy. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [1] A novel electrochemical impedance immunosensor for the quantification of CYFRA 21-1 in human serum
    Aydin, Elif Burcu
    Aydin, Muhammet
    Sezginturk, Mustafa Kemal
    MICROCHIMICA ACTA, 2023, 190 (06)
  • [2] A novel electrochemical impedance immunosensor for the quantification of CYFRA 21-1 in human serum
    Elif Burcu Aydın
    Muhammet Aydın
    Mustafa Kemal Sezgintürk
    Microchimica Acta, 2023, 190
  • [3] CYFRA 21-1 as a novel diagnostic serum biomarker in pancreatic cancer
    Kim, Jung Hoon
    Song, Joon Cheol
    Kwon, Jung Hyun
    Kim, Dae Kyun
    Jekarl, Dong Wook
    Jang, Jeong Won
    Yoon, Young Chul
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (03)
  • [4] CYFRA 21-1
    Pujol, JL
    REVUE DES MALADIES RESPIRATOIRES, 1997, 14 : S31 - S36
  • [5] Assessment of serum CYFRA 21-1 in lung cancer
    Muraki, M
    Tohda, Y
    Iwanaga, T
    Uejima, H
    Nagasaka, Y
    Nakajima, S
    CANCER, 1996, 77 (07) : 1274 - 1277
  • [6] Performance characteristics of an automated assay for the quantitation of CYFRA 21-1 in human serum
    Patel, Jay L.
    Erickson, J. Alan
    Roberts, William L.
    Grenache, David G.
    CLINICAL BIOCHEMISTRY, 2010, 43 (18) : 1449 - 1452
  • [7] Cutaneous apocrine carcinoma with elevated serum cytokeratin 19 fragment 21-1 (CYFRA 21-1)
    Fujioka, Mao
    Kato, Junji
    Sumikawa, Yasuyuki
    Sato, Sayuri
    Sawada, Masahide
    Uhara, Hisashi
    JOURNAL OF DERMATOLOGY, 2019, 46 (10): : E387 - E388
  • [8] CYFRA 21-1 serum analysis in patients with esophageal cancer
    Brockmann, JG
    St Nottberg, H
    Glodny, B
    Heinecke, A
    Senninger, NJ
    CLINICAL CANCER RESEARCH, 2000, 6 (11) : 4249 - 4252
  • [9] CYFRA 21-1: AN OVERVIEW
    Jose, Jithin
    Sunil, P. M.
    Nirmal, R. Madhavan
    Varghese, Soma Susan
    ORAL & MAXILLOFACIAL PATHOLOGY JOURNAL, 2013, 4 (02) : 368 - 371
  • [10] Primary mediastinal choriocarcinoma with elevated serum CYFRA 21-1
    Nakamura H.
    Nakahama H.
    Kitada O.
    Sugita M.
    International Journal of Clinical Oncology, 1999, 4 (5) : 315 - 317