ACCURACY OF CT AND MRI FOR CONTOURING THE FELINE OPTIC APPARATUS FOR RADIATION THERAPY PLANNING

被引:6
|
作者
Nolan, Michael W. [1 ]
Randall, Elissa K. [1 ]
LaRue, Susan M. [1 ]
Lunn, Katharine F. [2 ]
Stewart, Jeff [1 ]
Kraft, Susan L. [1 ]
机构
[1] Colorado State Univ, Dept Environm & Radiol Hlth Sci, Ft Collins, CO 80523 USA
[2] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC 27607 USA
关键词
acromegaly; brain tumors; optic chiasm; optic pathway; stereotactic radiation therapy; radiosurgery; CRANIAL NERVE EMERGENCE; SKULL FORAMINA; RADIOSURGERY; TOLERANCE;
D O I
10.1111/vru.12070
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Consistency and accuracy in normal tissue contouring in radiotherapy planning is important for comparison of dosimetry and toxicity data between studies. The purpose of this study was to determine whether magnetic resonance imaging (MRI) improves the accuracy of optic apparatus contouring as compared with computed tomography (CT) in both normal and acromegalic cats, and to construct a reference contour of the feline optic apparatus. Both CT and MRI were performed on cadavers of four healthy cats, as well as on five radiotherapy patients with feline acromegaly. Contours of the optic apparatus were drawn for each imaging study. The volume, center of mass, and the degree of concordance and mismatch were determined for each, and compared with a reference standard. Precontrast CT was found to overestimate volume as compared with MRI in acromegalic cats; no other statistically significant differences were identified in the volume, concordance index or mismatch index values of normal or acromegalic cats. Contours derived from T2-wieghted MRI were subjectively considered to best match the reference standard. The caudal margin of the optic chiasm and the optic tracts were difficult to confidently contour regardless of which imaging modality and/or sequence was used. In conclusion, findings from the current study supported the use of a combination of CT and MR images and a priori knowledge of the shape of the optic apparatus to guide accurate contouring, especially where image contrast is not sufficient to clearly delineate the margins. Guidelines for feline optic apparatus contouring developed in this study can be used for future studies. (C) 2013 Veterinary Radiology & Ultrasound.
引用
收藏
页码:560 / 566
页数:7
相关论文
共 50 条
  • [1] Contouring variability with CT and MRI of prostate cancer for radiation planning
    Otero-Romero, A.
    Perez-Rozos, A.
    Correa-Generoso, R.
    Jerez-Sainz, I.
    Garcia-Anaya, M. J.
    Zapata-Martinez, I.
    Roman-Jobacho, A.
    Toledo-Serrano, M. D.
    Ordonez-Marmolejo, R.
    Garcia-Rios, I.
    Gomez-Millan, J.
    Villalobos-Martin, J. A.
    Diaz-Antonio, T.
    Medina-Carmona, J. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S714 - S714
  • [2] Brachial Plexus Contouring with CT and MR Imaging in Radiation Therapy Planning for Head and Neck Cancer
    Minh Tam Truong
    Nadgir, Rohini N.
    Hirsch, Ariel E.
    Subramaniam, Rathan M.
    Wang, Jimmy W.
    Wu, Rebecca
    Khandekar, Melin
    Nawaz, A. Omer
    Sakai, Osamu
    RADIOGRAPHICS, 2010, 30 (04) : 1095 - 1103
  • [3] MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning
    Lambert, Jonathan
    Greer, Peter B.
    Menk, Fred
    Patterson, Jackie
    Parker, Joel
    Dahl, Kara
    Gupta, Sanjiv
    Capp, Anne
    Wratten, Chris
    Tang, Colin
    Kumar, Mahesh
    Dowling, Jason
    Hauville, Sarah
    Hughes, Cynthia
    Fisher, Kristen
    Lau, Peter
    Denham, James W.
    Salvado, Olivier
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) : 330 - 334
  • [4] Automated Contouring and Planning in Radiation Therapy: What Is 'Clinically Acceptable'?
    Baroudi, Hana
    Brock, Kristy K.
    Cao, Wenhua
    Chen, Xinru
    Chung, Caroline
    Court, Laurence E.
    El Basha, Mohammad D.
    Farhat, Maguy
    Gay, Skylar
    Gronberg, Mary P.
    Gupta, Aashish Chandra
    Hernandez, Soleil
    Huang, Kai
    Jaffray, David A.
    Lim, Rebecca
    Marquez, Barbara
    Nealon, Kelly
    Netherton, Tucker J.
    Nguyen, Callistus M.
    Reber, Brandon
    Rhee, Dong Joo
    Salazar, Ramon M.
    Shanker, Mihir D.
    Sjogreen, Carlos
    Woodland, McKell
    Yang, Jinzhong
    Yu, Cenji
    Zhao, Yao
    DIAGNOSTICS, 2023, 13 (04)
  • [5] COMPARISON OF CT AND MRI IN RADIATION-THERAPY TREATMENT PLANNING FOR CNS TUMORS
    RUBENSTEIN, JH
    HACKNEY, DB
    NELSON, DF
    ZIMMERMAN, RA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1987, 8 (05) : 955 - 955
  • [6] CT and MRI fusion to minimize contouring uncertainties in Stereotactic Radiosurgery (SRS) planning
    Payanova, I.
    Georgiev, R.
    Lazarov, R.
    Spasova, Z.
    Ivanov, V.
    Iliev, L.
    Tsenov, P.
    Antonova, A.
    Georgieva, T.
    Georgieva, S.
    Avgerinova, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S983 - S984
  • [7] PET/CT in Radiation Therapy Planning
    Specht, Lena
    Berthelsen, Anne Kiil
    SEMINARS IN NUCLEAR MEDICINE, 2018, 48 (01) : 67 - 75
  • [8] Automated integration of CT, MRI, and PET for planning and dose distribution computation in radiation therapy
    Rohlfing, T
    Beier, J
    Graf, R
    Wolf, M
    Wust, P
    Felix, R
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 279 - 283
  • [9] MRI and MRSI in radiation therapy treatment planning
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 2078 - 2078
  • [10] The Contouring Error of the Parotids Based On the CT and MRI Images in Radiotherapy Planning for Nasopharyngeal Carcinoma
    Gong, G.
    Liu, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 181 - 181