Out-of-Step Protection Using Equal Area Criterion in Time Domain

被引:0
|
作者
Sauhats, Antans [1 ]
Utans, Andrejs [1 ]
Antonovs, Dmitrijs [1 ]
Biela-Dalidovicha, Edite [1 ]
机构
[1] Riga Tech Univ, Inst Power Engn, Riga, Latvia
关键词
angular instability; out-of-step protection; equal area criterion in time domain; wide-area measurements; SLOW COHERENCY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes the out-of-step (OOS) protection system, which operation principle is based on combination of two approaches: equal area criterion, implemented in time domain, is used for generators first swing stability assessment and generation sources electromotive forces (emf) vectors angle control is used for multi swing instability detection. The paper focuses on possibilities of practical implementation of the above mentioned approaches within real time operating OOS protection system. Protection system structure and principles of operation addressed in the paper.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Application of Equal Area Criterion Conditions in the Time Domain for Out-of-Step Protection
    Paudyal, Sumit
    Ramakrishna, Gokaraju
    Sachdev, Mohindar S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) : 600 - 609
  • [2] Out-of-Step Protection Based on Equal Area Criterion
    Alinezhad, Bahman
    Karegar, Hossein Kazemi
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (02) : 968 - 977
  • [3] Out-of-step Protection Using the Equal Area Criterion in Time Domain - SMIB and 3-Machine Case Studies
    Paudyal, Sumit
    Ramakrishna, G.
    Sachdev, Mohindar S.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 1382 - 1387
  • [4] Equal Area Criterion and Angle control-based Out-of-Step Protection
    Sauhats, Antans
    Utans, Andrcjs
    Biela-Dalidovicha, Editc
    2017 IEEE 58TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2017,
  • [5] A Novel Fast Algorithm for Detecting Out-of-Step Using Equal Area Criterion
    Aghazadeh, Mohsen
    Kazemi, Ahad
    2016 24TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2016, : 931 - 936
  • [6] Out-of-step Protection combining Three-impedance Element Model with the Equal Area Criterion
    Yuan, Liang
    Zhang, Zhaorong
    Chen, Chong
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION (IFEEA 2015), 2016, 54 : 18 - 23
  • [7] Out-of-step Detection Using Energy Equilibrium Criterion in Time Domain
    Paudyal, Sumit
    Gokaraju, Ramakrishna
    Sachdev, Mohindar S.
    Cheng, Shengli
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (07) : 714 - 739
  • [8] Predictive out-of-step relay based on equal area criterion and PMU data
    Alinezhad, Bahman
    Karegar, Hossein Kazemi
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2017, 27 (07):
  • [9] Adaptive Mitigation of Out-of-Step Transients Based on Equal Area Criterion and Energy Balance
    Blood, Ellery A.
    2017 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2017,
  • [10] Out-of-step protection of synchronous generators based on a digital phase comparison in the time domain
    Ostojic, Mladen M.
    Djuric, Milenko B.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (04) : 873 - 879