Restoration of patency in failing tunneled hemodialysis catheters:: A comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping

被引:54
|
作者
d'Othée, Bertrand Janne [1 ]
Tham, Jacques C. [1 ]
Sheiman, Robert G. [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Sect Intervent Radiol,Dept Radiol, Boston, MA 02215 USA
关键词
D O I
10.1097/01.RVI.0000223692.99800.2E
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare median patency times after treatment of malfunctioning tunneled hemodialysis catheters by one of three techniques: over-the-wire catheter exchange (CE), fibrin sheath stripping (FSS) from a femoral vein approach, and over-the-wire catheter removal with balloon dilation of fibrin sheath (DFS) followed by catheter replacement with use of the same tract. MATERIALS AND METHODS: Retrospective study was conducted of 66 consecutive procedures performed over a period of 47 months for poor flow through tunneled hemodialysis catheters despite tissue plasminogen activator infusion trials (CE, n = 33; FSS, n = 18; DFS, n = 15). Baseline parameters (time since initial catheter placement, number of previous catheter interventions, catheter access site, and patient age and sex) were recorded to identify possible pretreatment differences among groups. Outcome comparison was based on duration of adequate catheter function on dialysis during follow-up. RESULTS: No significant differences in baseline parameters were identified among the three groups (P >.05). Mean follow-up duration (67 +/- 89 days; range, 0-398 d) was similar among the three groups. The immediate technical success rate was 100%, and there were no complications. Cumulative catheter patency rates were 73% (CE), 72% (FSS), and 65% (DFS) at 1 month; 43% (CE), 60% (FSS), and 39% (DFS) at 3 months; and 28% (CE), 45% (FSS), and 39% (DFS) at 6 months. Median duration of patency was similar among groups (P =.60). CONCLUSIONS: All three therapies were equivalent in terms of immediate technical success, complication rates, and durability of catheter function during later follow-up. Hence, when one technique is chosen over another, factors other than the period of secondary patency should be considered, such as cost and patient and physician preference.
引用
收藏
页码:1011 / 1015
页数:5
相关论文
共 11 条
  • [1] Fibrin sheath stripping versus catheter exchange for the treatment of failed tunneled hemodialysis catheters: Randomized clinical trial
    Merport, M
    Murphy, TP
    Egglin, TK
    Dubel, GJ
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (09) : 1115 - 1120
  • [2] Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters
    Brady, PS
    Spence, LD
    Levitin, A
    Mickolich, CT
    Dolmatch, BL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) : 1023 - 1027
  • [3] Failing hemodialysis catheters: Fibrin sheath stripping versus exchange through existing subcutaneous tunnel
    Szymski, GX
    Rosenblum, JD
    Leef, JA
    Zernich, BW
    RADIOLOGY, 1996, 201 : 1551 - 1551
  • [4] Balloon angioplasty for disruption of tunneled dialysis catheter fibrin sheath
    Watorek, Ewa
    Golebiowski, Tomasz
    Letachowicz, Krzysztof
    Garcarek, Jerzy
    Kurcz, Jacek
    Bartosik, Hanna Augustyniak
    Letachowicz, Waldemar
    Weyde, Waclaw
    Klinger, Marian
    JOURNAL OF VASCULAR ACCESS, 2012, 13 (01): : 111 - 114
  • [5] Patency rates of dysfunctional central hemodialysis venous catheter: Comparison between catheter exchange alone and catheter exchange with fibrin sheath angioplasty
    Maldonado-Carceles, A. B.
    Garcia-Medina, J.
    Garcia-Alfonso, J. J.
    Arense-Gonzalo, J. J.
    Torres-Cantero, A. M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (03) : 157 - 162
  • [6] Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia
    Valliant, Amanda M.
    Chaudhry, Muhammad K.
    Yevzlin, Alexander S.
    Astor, Brad
    Chan, Micah R.
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (01): : 52 - 56
  • [7] Tunneled dialysis catheter exchange through fibrin sheath crevice vs in situ catheter exchange for the treatment of catheter dysfunction
    Li, Li
    Zhan, Shen
    Zhang, Lihong
    Yang, Tao
    Hou, Xibin
    Ren, Shufeng
    Wang, Yuzhu
    THERAPEUTIC APHERESIS AND DIALYSIS, 2020, 24 (06) : 695 - 702
  • [9] Fibrin Sheath and its Relation to Subsequent Events after Tunneled Dialysis Catheter Exchange
    Shanaah, Almothana
    Brier, Michael
    Dwyer, Amy
    SEMINARS IN DIALYSIS, 2013, 26 (06) : 733 - 737
  • [10] Exchange over the guidewire from non-tunneled to tunneled hemodialysis catheters can be performed without patency loss
    Park, Hoon Suk
    Choi, Joonsung
    Kim, Hyung Wook
    Baik, Jun Hyun
    Park, Cheol Whee
    Kim, Young Ok
    Yang, Chul Woo
    Jin, Dong Chan
    JOURNAL OF VASCULAR ACCESS, 2018, 19 (03): : 252 - 257