Performance comparison of two absorption-compression hybrid refrigeration systems using R1234yf/ionic liquid as working pair

被引:92
|
作者
Liu, Xiangyang [1 ]
Ye, Zheng [1 ]
Bai, Lihang [1 ]
He, Maogang [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermal Fluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Absorption-compression refrigeration system; HFO; Ionic liquid; Coefficient of performance; Circulation ratio; IONIC LIQUIDS; THERMODYNAMIC ANALYSIS; HEAT-CAPACITIES; EXERGY ANALYSIS; CYCLES; ENERGY; WATER; ABSORBENTS; HYDROFLUOROOLEFINS; SOLUBILITIES;
D O I
10.1016/j.enconman.2018.12.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
R1234yf (2,3,3,3-tetrafluoroprop-1-ene)/ionic liquid is a kind of environment-friendly working pair, which can overcome the disadvantages of H2O/LiBr and NH3/H2O. In this work, three new working pairs R1234yf/[HMIM] [TfO], R1234yf/[HMIM] [PF6], R1234yf/[HMIM] [BF4] were proposed and new solubility data for them were determined. Two new absorption-compression hybrid refrigeration systems were proposed to improve the cooling performances of the single-effect absorption refrigeration system using R1234yf/[HMIM][TfO], R1234yf/[HMIM] [PF6] and R1234yf/[HMIM] [BF4] as working pair. The effects of compressor position, compression ratio (r), generation temperature (T-g), evaporation temperature (T-e), condensation temperature (T-c) and absorption temperature (T-a) on the coefficient of performance (COP) and circulation ratio (f) were analyzed. Comparison result shows that the two systems can effectively improve the cooling performance of the single effect absorption refrigeration system including increasing COP, reducing the heat load of condenser and f, and enlarge the operation range of T-g, T-a, and T-e. Putting compressor between evaporator and absorber is a better choice than putting it between generator and condenser. R1234yf/[HMIM] [TfO] shows better cooling performance than R1234yf/[HMIM] [PF6] and R1234yf/[HMIM][BF4] due to its favorable thermophysical properties.
引用
收藏
页码:319 / 330
页数:12
相关论文
共 50 条
  • [1] Performance analysis of R1234yf/ionic liquid working fluids for single-effect and compression-assisted absorption refrigeration systems
    Sun, Yanjun
    Di, Gaolei
    Wang, Jian
    Wang, Xiaopo
    Wu, Wei
    International Journal of Refrigeration, 2020, 109 : 25 - 36
  • [2] Performance analysis of R1234yf/ionic liquid working fluids for single-effect and compression-assisted absorption refrigeration systems
    Sun, Yanjun
    Di, Gaolei
    Wang, Jian
    Wang, Xiaopo
    Wu, Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 : 25 - 36
  • [3] Statistical analysis of the energy performance of a refrigeration system working with R1234yf using artificial neural networks
    Belman-Flores, J. M.
    Ledesma, Sergio
    APPLIED THERMAL ENGINEERING, 2015, 82 : 8 - 17
  • [4] Theoretical energy performance evaluation of different single stage vapour compression refrigeration configurations using R1234yf and R1234ze(E) as working fluids
    Moles, Francisco
    Navarro-Esbri, Joaquin
    Peris, Bernardo
    Mota-Babiloni, Adrian
    Barragan-Cervera, Angel
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 44 : 141 - 150
  • [5] Theoretical energy performance evaluation of different single stage vapour compression refrigeration configurations using R1234yf and R1234ze(E) as working fluids
    Molés, Francisco
    Navarro-Esbrí, Joaquín
    Peris, Bernardo
    Mota-Babiloni, Adrián
    Barragán-Cervera, Ángel
    International Journal of Refrigeration, 2014, 44 : 141 - 150
  • [6] Experimental comparison of an air-to-water refrigeration system working with R134a and R1234yf
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 124 - 131
  • [7] Gaseous solubility and thermodynamic performance of absorption system using R1234yf/IL working pairs
    Sun, Yanjun
    Di, Gaolei
    Wang, Jian
    Hu, Yusheng
    Wang, Xiaopo
    He, Maogang
    APPLIED THERMAL ENGINEERING, 2020, 172 (172)
  • [8] Performance improvement strategies of R1234yf in vapor compression refrigeration system as a R134a replacement: A review
    Sharif, M. Z.
    Azmi, W. H.
    Ghazali, M. F.
    Samykano, M.
    Ali, Hafiz Muhammad
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 148
  • [9] Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
    Yataganbaba, Alptug
    Kilicarslan, Ali
    Kurtbas, Irfan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 60 : 26 - 37
  • [10] Performance evaluation of an absorption refrigeration system using R1234yf-organic absorbents working fluids
    Khelifa, Salhi
    Ramadan, Khaled
    Ammar, Mohammed Ali Hadj
    Mohammed Moundji, Hadjiat
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2021, 27 (07) : 936 - 947