Study on method of dose estimation for the Dual-moderated neutron survey meter

被引:1
|
作者
Zhou, Bo [1 ]
Li, Taosheng [1 ]
Xu, Yuhai [1 ]
Gong, Cunkui [1 ]
Yan, Qiang [1 ]
Li, Lei [1 ]
机构
[1] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin 150001, Peoples R China
关键词
High energy neutron; Ambient dose equivalent; Survey meter; ACCELERATOR BEAM DUMP; OF-FLIGHT SPECTRA; PROPORTIONAL-COUNTERS; LATERAL SHIELD; DETECTOR; DESIGN; ENERGY;
D O I
10.1016/j.radmeas.2013.04.018
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to study neutron dose measurement in high energy radiation field, a Dual-moderated survey meter in the range from 1 key to 300 MeV mean energies spectra has been developed. Measurement results of some survey meters depend on the neutron spectra characteristics in different neutron radiation fields, so the characteristics of the responses to various neutron spectra should be studied in order to get more reasonable dose. In this paper the responses of the survey meter were calculated under different neutron spectra data from IAEA of Technical Reports Series No. 318 and other references. Finally one dose estimation method was determined. The range of the reading per H*(10) for the method estimated is about 0.7-1.6 for the neutron mean energy range from 50 key to 300 MeV. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 83
页数:3
相关论文
共 37 条
  • [1] Study on influence of dual-moderated type dose detectors for high-energy neutrons
    Yue, Zhi-Xi
    Li, Tao-Sheng
    Jiao, Nan-Jie
    Gong, Cun-Kui
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (SUPPL. 1): : 467 - 471
  • [2] Evaluation of fluence-to-dose response function of neutron survey meter using singular value decomposition method
    Le, Ngoc-Thiem
    Nguyen, Ngoc-Quynh
    Anh, Nguyen Ngoc
    Tran, Hoai-Nam
    Liamsuwan, Thiansin
    Bui, Van-Loat
    Nguyen, Tuan-Khai
    Pham, Duc-Khue
    Dinh, Tien-Hung
    Cao, Van-Chung
    RADIATION MEASUREMENTS, 2024, 178
  • [3] Phenomenon involving the change in neutron survey meter efficiency versus accumulated dose
    Piper, RK
    Murphy, MK
    Thompson, AK
    HEALTH PHYSICS, 2005, 89 (01): : S30 - S30
  • [4] Measurement of Neutron Dose Equivalent within and Outside of a LINAC Treatment Vault Using a Neutron Survey Meter
    Tai, Duong Thanh
    Loan, Truong Thi Hong
    Sulieman, Abdelmoneim
    Tamam, Nissren
    Omer, Hiba
    Bradley, David A.
    QUANTUM BEAM SCIENCE, 2021, 5 (04)
  • [5] Estimation of photon and neutron dose distributions in the THOR BNCT treatment room using dual TLD method
    Hsu, F. Y.
    Chi, M. C.
    Chang, Y. L.
    Yu, C. C.
    Liu, H. M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1089 - 1094
  • [6] Dual-Frequency Soil Moisture Meter Method for Simultaneous Estimation of Soil Moisture and Conductivity
    Witkowski, Jerzy S.
    Grobelny, Andrzej F.
    SENSORS, 2024, 24 (10)
  • [7] A Monte Carlo design of a neutron dose-equivalent survey meter based on a set of 3He proportional counters
    Li, Taosheng
    Fang, Dong
    Li, Hong
    RADIATION MEASUREMENTS, 2007, 42 (01) : 49 - 54
  • [8] A COMBINED REAL-TIME WIDE ENERGY-RANGE NEUTRON DOSIMETER AND SURVEY METER FOR HIGH NEUTRON DOSE-RATES WITH SI SURFACE-BARRIER DETECTORS
    EISEN, Y
    ENGLER, G
    OVADIA, E
    SHAMAI, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 211 (01): : 171 - 178
  • [9] Dose estimation of the radiation workers in the SK cyclotron center using dual-TLD method
    Kuo, Ming-Jay
    Hsu, Fang-Yuh
    Hsu, Ching-Han
    Lo, Ching-Huang
    Chen, Chien-Ming
    Chang, Yen-Lin
    Chao, Jiunn-Hsing
    Yin, Kuo-Wei
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 691 - 693
  • [10] Monte Carlo study of neutron production in the 15 MV mode of a siemens primus accelerator and estimation of the neutron dose in IMRT deliveries
    Becker, J.
    Brunckhorst, E.
    Schmidt, R.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S47 - S47