Eigenmode analysis for understanding phased array coils and their limits

被引:19
|
作者
King, SB
Varosi, SM
Duensing, GR
机构
[1] Natl Res Council Canada, Inst Biodiagnost, Winnipeg, MB R3B 1Y6, Canada
[2] InVivo Corp, Gainesville, FL USA
关键词
phased array; eigenmode; signal-to-noise ratio (SNR); eigenvalue; resistance;
D O I
10.1002/cmr.b.20054
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
What are the fundamental limits to phased array SNR gain and how do non-sample related loss mechanisms affect these SNR limits? In this article we use eigenmode analysis to understand the SNR behavior of phased array coils that would manifest with changes in design parameters, such as frequency, the number of receive channels and the amount of non-sample losses, such as conductor resistance or preamplifier noise. Eigenmode analysis easily explains why a 30% change in array element conductor resistance results in only a 6% drop in isocenter SNR, as might be seen with single channel coils such as the birdcage, but a surprising 25% drop in peripheral SNR should be expected. As the number of receivers available on MRI scanners is increased, arrays of smaller sized elements can be used to produce additional eigenmodes of higher-order spatial SNR distribution. The SNR gain associated with these new volume arrays will be more and more pushed to the periphery, such that for typical head coil filling factors, the SNR gain may be outside the sample. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [1] Eigenmode analysis of the scattering matrix for the design of MRI transmit array coils
    Kazemivalipour, Ehsan
    Sadeghi-Tarakameh, Alireza
    Atalar, Ergin
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1727 - 1741
  • [2] Moment method analysis of mutual interaction in MRI phased array coils
    Hiroyuki Fujita
    John W. Missal
    Michael A. Morich
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2000, 10 (2) : 84 - 92
  • [3] Moment method analysis of mutual interaction in MRI phased array coils
    Fujita, Hiroyuki
    Missal, John W.
    Morich, Michael A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2000, 10 (02) : 84 - 92
  • [4] Parallel MRI Using Phased Array Coils
    Ying, Leslie
    Liang, Zhi-Pei
    IEEE SIGNAL PROCESSING MAGAZINE, 2010, 27 (04) : 90 - 98
  • [5] PHASED-ARRAY COILS FOR UPPER EXTREMITY MRA
    MONROE, JW
    SCHMALBROCK, P
    SPIGOS, DG
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) : 224 - 229
  • [6] Mouse MRI using phased-array coils
    Gareis, Daniel
    Wichmann, Tobias
    Lanz, Titus
    MeIkus, Gerd
    Horn, Michael
    Jakob, Peter M.
    NMR IN BIOMEDICINE, 2007, 20 (03) : 326 - 334
  • [7] Phased array coils for high resolution prostate MR imaging
    Yung, AC
    Oner, AY
    Serfaty, JM
    Feleney, M
    Yang, XM
    Atalar, E
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 2330 - 2333
  • [8] Dynamic MRI using spatiotemporal modeling with phased array coils
    Xu, Dan
    Ying, Leslie
    Liang, Zhi-Pei
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 722 - +
  • [9] Use of phased array coils for a determination of absolute metabolite concentrations
    Natt, O
    Bezkorovaynyy, V
    Michaelis, T
    Frahm, J
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 3 - 8
  • [10] CARCINOMA OF THE PROSTATE-GLAND - MR-IMAGING WITH PELVIC PHASED-ARRAY COILS VERSUS INTEGRATED ENDORECTAL PELVIC PHASED-ARRAY COILS
    HRICAK, H
    WHITE, S
    VIGNERON, D
    KURHANEWICZ, J
    KOSCO, A
    LEVIN, D
    WEISS, J
    NARAYAN, P
    CARROLL, PR
    RADIOLOGY, 1994, 193 (03) : 703 - 709