关键词
Partial discharges; Insulation; Fluctuations; Voltage fluctuations; Degradation; Electric potential; Power transformer insulation; On-board traction transformers; PD; surface potential; trap distribution; three-layer oil-paper insulation; PULSE VOLTAGE COMBINATION; SURFACE-CHARGE DECAY; DC; INSULATION; AC; FREQUENCY; BREAKDOWN; SYSTEM; MODEL;
D O I
10.1109/ACCESS.2020.3024774
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Trap plays an important role in the charge transportation of three-layer oil-paper and the investigation of trap parameters at different degradation degree is of great significance for further research of the partial discharge (PD) mechanism. This article considers the turn-to-turn structure of on-board traction transformer. A defect model of three-layer oil-paper insulation was designed for PD test. The PD degradation samples are selected from the inception of PD to the breakdown of PD to study the characteristics of surface potential decay on degradation samples by using isothermal surface potential decay method. Given that, the trap distribution at different degradation stages was calculated and its influence on PD characteristics was investigated. The result shows that AC fluctuation voltages caused by inter-harmonic has a great influence on PD distribution, surface charge distribution and trap distribution. With the increase of degradation, the decay rate of surface potential increases and the decay rate of AC fluctuation voltages is larger than that pure AC. And also, the number of shallow trap with AC fluctuation voltages is larger than that with pure AC. The rate of free charge increases with the number of shallow trap increasing. More free electrons involves in the process of PD, accelerating the aging rate of three-layer oil paper samples. Therefore, it can be concluded that surface charge and trap distribution are helpful to clarify PD mechanism.
引用
收藏
页码:175651 / 175659
页数:9
相关论文
共 18 条
  • [1] Partial discharge characteristics of oil-paper insulation for on-board traction transformers under superposed inter-harmonic AC voltages
    Li, Xiaonan
    Wu, Guangning
    Yang, Yan
    Wang, Zijie
    Xu, Ping
    Li, Yixuan
    Gao, Bo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (01) : 240 - 248
  • [2] Evolution of Trapping Parameters of Multi-layer Oil-paper Insulating Medium at Different Partial Discharge Stages
    Li Y.
    Gao B.
    Li X.
    Yang Y.
    Xu P.
    Wang Z.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (01): : 260 - 268
  • [3] Experimental Study on the Evolution of Surface Discharge for Oil-Paper Insulation in Transformers
    Wang Hui
    Li Cheng-rong
    Sheng Kang
    Miao Yinyin
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 354 - 357
  • [4] Effect of Aging Degree on Partial Discharge Degradation of Oil-paper Insulation
    Wang Y.
    Wang Z.
    Zeng Z.
    Fei R.
    Shang J.
    IEEE Transactions on Dielectrics and Electrical Insulation, 2021, 28 (06) : 2099 - 2107
  • [5] Evolution of Bubble in Oil-paper Insulation and Its Influence on Partial Discharge
    Zheng, Zhong
    Chen, Lihua
    Diao, Junwei
    Wang, Rongliang
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 220 - 223
  • [6] Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory
    Gao, Jun
    Wang, Youyuan
    Liao, Ruijin
    Wang, Ke
    Yuan, Lei
    Zhang, Yiyi
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (05) : 1686 - 1693
  • [7] Statistical parameters of partial discharge used to recognize aged oil-paper insulation
    Li, Jian
    Grzybowski, S.
    Yang, Lijun
    Liao, Ruijin
    PROCEEDINGS OF THE 27TH INTERNATIONAL POWER MODULATOR SYMPOSIUM AND 2006 HIGH VOLTAGE WORKSHOPS, 2006, : 75 - +
  • [8] An Advanced Method for Detection of Partial Discharge in Oil-paper insulated Transformer Bushings and Current Transformers
    Xu, Yang
    Liu, Weidong
    Gao, Wensheng
    Zhang, Xiancong
    2016 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2016, : 695 - 700
  • [9] Moisture Migration in an Oil-Paper Insulation System in Relation to Online Partial Discharge Monitoring of Power Transformers
    Sikorski, Wojciech
    Walczak, Krzysztof
    Przybylek, Piotr
    ENERGIES, 2016, 9 (12)
  • [10] Partial Discharge Characteristics and Trap Parameters Analysis of Oil-paper After Thermal Aging
    Wei, Yanhui
    Zhu, Mingxiao
    You, Xiaoyu
    Deng, Junbo
    Mu, Haibao
    Zhang, Guanjun
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 416 - 419