Calculation of the store house worker dose in a lost wax foundry using MCNP-4C

被引:1
|
作者
Alegría, N [1 ]
Legarda, F [1 ]
Herranz, M [1 ]
Idoeta, R [1 ]
机构
[1] Univ Basque Country, Dept Nucl Engn & Fluid Mech, Bilbao 48013, Spain
关键词
D O I
10.1093/rpd/nci156
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lost wax casting is an industrial process which permits the transmutation into metal of models made in wax. The wax model is covered with a silicaceous shell of the required thickness and once this shell is built the set is heated and wax melted. Liquid metal is then cast into the shell replacing the wax. When the metal is cool, the shell is broken away in order to recover the metallic piece. In this process zircon sands are used for the preparation of the silicaceous shell. These sands have varying concentrations of natural radionuclides: 238U, 232Th and 235U together with their progenics. The zircon sand is distributed in bags of 50 kg, and 30 bags are on a pallet, weighing 1,500 kg. The pallets with the bags have dimensions 80 cm x 120 cm x 80 cm, and constitute the radiation source in this case. The only pathway of exposure to workers in the store house is external radiation. In this case there is no dust because the bags are closed and covered by plastic, the store house has a good ventilation rate and so radon accumulation is not possible. The workers do not touch with their hands the bags and consequently skin contamination will not take place. In this study all situations of external irradiation to the workers have been considered; transportation of the pallets from vehicle to store house, lifting the pallets to the shelf, resting of the stock on the shelf, getting down the pallets, and carrying the pallets to production area. Using MCNP-4C exposure situations have been simulated, considering that the source has a homogeneous composition, the minimum stock in the store house is constituted by 7 pallets, and the several distances between pallets and workers when they are at work. The photons flux obtained by MCNP-4C is multiplied by the conversion factor of Flux to Kerma for air by conversion factor to Effective Dose by Kerma unit, and by the number of emitted photons. Those conversion factors are obtained of ICRP 74 table 1 and table 17 respectively. This is the way to obtain a function giving dose rate around the source.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 29 条
  • [1] Calculating the absorbed dose by thyroid in breast cancer radiotherapy using MCNP-4C code
    Taghavi, Roghayeh
    Mirzaei, Hamid Reza
    Aghamiri, Seyed Mahmoud Reza
    Hajian, Parastoo
    RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 12 - 14
  • [2] Calculation and comparison of the neutron energy flux spectra in the Syrian MNSR irradiation sites using the MCNP-4C code
    Khattab, K.
    Sulieman, I.
    PROGRESS IN NUCLEAR ENERGY, 2010, 52 (04) : 307 - 314
  • [3] Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code
    Zevallos-Chávez, JY
    Zamboni, CB
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 797 - 800
  • [4] Gamma-ray shielding study of light to heavyweight concretes using MCNP-4C code
    Bagheri, Reza
    Moghaddam, Alireza Khorrami
    Yousefi, Ali
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (02)
  • [5] Gamma-ray shielding study of light to heavyweight concretes using MCNP-4C code
    Reza Bagheri
    Alireza Khorrami Moghaddam
    Ali Yousefi
    NuclearScienceandTechniques, 2017, 28 (02) : 43 - 49
  • [6] Gamma-ray shielding study of light to heavyweight concretes using MCNP-4C code
    Reza Bagheri
    Alireza Khorrami Moghaddam
    Ali Yousefi
    Nuclear Science and Techniques, 2017, 28
  • [7] Optimization of in-core fuel management strategy of Tehran Research Reactor (TRR) using MCNP-4C
    Keyvani, M.
    Arkani, M.
    Rokh, A. Hossni
    ANNALS OF NUCLEAR ENERGY, 2010, 37 (12) : 1683 - 1687
  • [8] Calculations of the thermal and fast neutron fluxes in the Syrian miniature neutron source reactor using the MCNP-4C code
    Khattab, K.
    Sulieman, I.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (04) : 535 - 538
  • [9] Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51
    Casanova, AO
    López, N
    Gelen, A
    Guevara, MVM
    Díaz, O
    Cimino, L
    D'Alessandro, K
    Melo, JC
    RADIATION PROTECTION DOSIMETRY, 2004, 109 (03) : 189 - 195
  • [10] Monte Carlo simulation of a conceptual thermal column in the Syrian miniature neutron source reactor using MCNP-4C
    Khamis, I
    Sulieman, I
    ANNALS OF NUCLEAR ENERGY, 2006, 33 (07) : 622 - 626