Intermittent-contact scanning capacitance microscopy versus contact mode SCM applied to 2D dopant profiling

被引:5
|
作者
Biberger, Roland [1 ]
Benstetter, Guenther [1 ]
Schweinboeck, Thomas [2 ]
Breitschopf, Peter [1 ]
Goebel, Holger [3 ]
机构
[1] Univ Appl Sci Deggendorf, D-94469 Deggendorf, Germany
[2] Infineon Technol, Failure Anal, D-81739 Munich, Germany
[3] Univ Bundeswehr Hamburg, Helmut Schmidt Univ, D-22043 Hamburg, Germany
关键词
6;
D O I
10.1016/j.microrel.2008.06.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study compares two different methods of scanning capacitance microscopy (SCM). The first and approved one operates in contact mode and the second novel one in intermittent-contact (IC) mode. Measurements were performed on several samples and the results are compared. New technical expertises on the novel intermittent-contact method are shown and in conclusion assets and drawbacks of this SCM method are emphasized. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1339 / 1342
页数:4
相关论文
共 45 条
  • [1] Intermittent contact scanning capacitance microscopy - An improved method for 2D doping profiling
    Breitschopf, P
    Benstetter, G
    Knoll, B
    Frammelsberger, W
    MICROELECTRONICS RELIABILITY, 2005, 45 (9-11) : 1568 - 1571
  • [2] Intermittent-contact scanning capacitance microscopy imaging and modeling for overlay metrology
    Mayo, S
    Kopanski, JJ
    Guthrie, WF
    CHARACTERIZATION AND METROLOGY FOR ULSI TECHNOLOGY, 1998, 449 : 567 - 572
  • [3] Quantification of scanning capacitance microscopy measurements for 2D dopant profiling
    Malberti, P
    Ciampolini, L
    Ciappa, M
    Fichtner, W
    MICROELECTRONICS RELIABILITY, 2000, 40 (8-10) : 1395 - 1399
  • [4] Intermittent-contact scanning capacitance microscope for lithographic overlay measurement
    Kopanski, JJ
    Mayo, S
    APPLIED PHYSICS LETTERS, 1998, 72 (19) : 2469 - 2471
  • [5] High-throughput intermittent-contact scanning probe microscopy
    Sahoo, Deepak R.
    Haeberle, Walter
    Sebastian, Abu
    Pozidis, Haralampos
    Eleftheriou, Evangelos
    NANOTECHNOLOGY, 2010, 21 (07)
  • [6] Nonlinear dynamics of intermittent-contact mode atomic force microscopy
    Berg, J
    Briggs, GAD
    PHYSICAL REVIEW B, 1997, 55 (22) : 14899 - 14908
  • [8] Displacement current sensor for contact and intermittent contact scanning capacitance microscopy
    Biberger, Roland
    Benstetter, Guenther
    Goebel, Holger
    MICROELECTRONICS RELIABILITY, 2009, 49 (9-11) : 1192 - 1195
  • [9] Non-contact and intermittent-contact scanning force microscopy of polyvinyl alcohol films.
    Haugstad, G
    Hammerschmidt, JA
    Gladfelter, WL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U159 - U160
  • [10] High-Bandwidth Intermittent-Contact Mode Scanning Probe Microscopy Using Electrostatically-Actuated Microcantilevers
    Sahoo, Deepak R.
    Haeberle, Walter
    Sebastian, Abu
    Pozidis, Haralampos
    Eleftheriou, Evangelos
    CONTROL TECHNOLOGIES FOR EMERGING MICRO AND NANOSCALE SYSTEMS, 2011, 413 : 119 - +