Automated Quantitative Analysis of Anterior Segment Inflammation Using Swept-Source Anterior Segment Optical Coherence Tomography: A Pilot Study

被引:4
|
作者
Keino, Hiroshi [1 ]
Aman, Takuto [2 ]
Furuya, Ryota [3 ]
Nakayama, Makiko [1 ]
Okada, Annabelle A. [1 ]
Sunayama, Wataru [3 ]
Hatanaka, Yuji [2 ]
机构
[1] Kyorin Univ, Dept Ophthalmol, Sch Med, 6-20-2 Shinkawa, Tokyo 1818611, Japan
[2] Oita Univ, Fac Sci & Engn, 700 Dannoharu, Oita 8701192, Japan
[3] Univ Shiga Prefecture, Fac Engn, 2500 Hassaka, Hikone 5228533, Japan
关键词
uveitis; anterior chamber inflammation; optical coherence tomography (OCT); image analysis; Standardization of Uveitis Nomenclature (SUN); CHAMBER INFLAMMATION; DIAGNOSTIC-CRITERIA; UVEITIS; FREQUENCY; DISEASE; SYSTEM;
D O I
10.3390/diagnostics12112703
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study is to develop an automated evaluation of anterior chamber (AC) cells in uveitis using anterior segment (AS) optical coherence tomography (OCT) images. Methods: We analyzed AS swept-source (SS)-OCT (CASIA 2) images of 31 patients (51 eyes) with uveitis using image analysis software (Python). An automated algorithm was developed to detect cellular spots corresponding to hyper-reflective spots in the AC, and the correlation with Standardization of Uveitis Nomenclature (SUN) grading AC cells score was evaluated. The approximated AC grading value was calculated based on the logarithmic approximation curve between the number of cellular spots and the SUN grading score. Results: Among 51 eyes, cellular spots were automatically segmented in 48 eyes, whereas three eyes (all SUN grading AC cells score: 4+) with severe fibrin formation in the AC were removed by the automated algorithm. The AC cellular spots increased with an increasing SUN grading score (p < 0.001). The 48 eyes were split into training data (26 eyes) and test data (22 eyes). There was a significant correlation between the SUN grading score and the number of cellular spots in 26 eyes (rho: 0.843, p < 0.001). There was a significant correlation between the SUN grading score and the approximated grading value of 22 eyes based on the logarithmic approximation curve (rho: 0.774, p < 0.001). Leave-one-out cross-validation analysis demonstrated a significant correlation between the SUN grading score and the approximated grading value of 48 eyes (rho: 0.748, p < 0.001). Conclusions: This automated anterior AC cell analysis using AS SS-OCT showed a significant correlation with clinical SUN grading scores and provided SUN AC grading values as a continuous variable. Our findings suggest that automated grading of AC cells could improve the accuracy of a quantitative assessment of AC inflammation using AS-OCT images and allow the objective and rapid evaluation of anterior segment inflammation in uveitis. Further investigations on a large scale are required to validate this quantitative measurement of anterior segment inflammation in uveitic eyes.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Automated quantification of anterior chamber cells using swept-source anterior segment optical coherence tomography
    Pillar, Shani
    Kadomoto, Shin
    Chen, Keren
    Gonzalez, Saitiel Sandoval
    Cherian, Nina
    Privratsky, Joseph K.
    Zargari, Nicolette
    Jackson, Nicholas J.
    Corradetti, Giulia
    Chen, Judy L.
    Sadda, SriniVas R.
    Holland, Gary N.
    Tsui, Edmund
    JOURNAL OF OPHTHALMIC INFLAMMATION AND INFECTION, 2025, 15 (01):
  • [2] Anterior Segment Angiography with 1050 nm Swept-Source Optical Coherence Tomography
    Li, Yan
    Lu, Chen D.
    Jia, Yali
    Lee, ByungKun
    Kraus, Martin F.
    Hornegger, Joachim
    Fujimoto, James G.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [3] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [4] Dynamic imaging of accommodation by swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Ruggeri, Marco
    Protti, Alessandra
    Lead, Rosachiara
    Gandolfi, Stefano A.
    Macaluso, Claudio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03): : 501 - 510
  • [5] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [6] Evaluating Anterior Chamber Inflammation in Uveitis and Control patients: Cell Area Analysis Using Swept-Source Anterior Segment Optical Coherence Tomography
    Oo, Hnin Hnin
    Gonzalez, Carlos Cifuentes
    Boon, Joewee
    Rojas-Carabali, William
    Choo, Shannon
    Lam, Hilbert Yuen In
    Wei, Xin
    Mu, Yuguang
    Agrawal, Rupesh Vijay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [7] Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
    Higashiyama, Tomoaki
    Iwasa, Maki
    Ohji, Masahito
    PLOS ONE, 2017, 12 (08):
  • [8] Clinical applications of anterior segment swept-source optical coherence tomography: A systematic review
    Mirzayev, Ibadulla
    Gündüz, Ahmet Kaan
    Ellialtioglu, Pinar Aydin
    Gündüz, Omuer Ozlenen
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 42
  • [9] Role of swept-source anterior segment optical coherence tomography in imaging pediatric cataract
    Bhardwaj, Anand
    Kaur, Savleen
    Sukhija, Jaspreet
    Gupta, Parul Chawla
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 2132 - 2138
  • [10] Pigmented Iris Lesion on Anterior-Segment Swept-Source Optical Coherence Tomography
    Vaidya, Sarangdev
    Yaghy, Antonio
    Shields, Carol L.
    JAMA OPHTHALMOLOGY, 2021, 139 (01)