Condensation of downward-flowing HFC134a in a staggered bundle of horizontal finned tubes: effect of fin geometry

被引:25
|
作者
Honda, H [1 ]
Takata, N
Takamatsu, H
Kim, JS
Usami, K
机构
[1] Kyushu Univ, Inst Adv Mat Study, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Kasuga, Fukuoka 8168580, Japan
关键词
heat transfer; condensation; R134a; array; fin; geometry; coefficient of heat transfer;
D O I
10.1016/S0140-7007(01)00023-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental results are presented that show the effect of fin geometry on condensation of refrigerant HFC134a in a staggered bundle of horizontal finned tubes. Two types of conventional low-fin tubes and three types of three-dimensional fin tubes were tested. The refrigerant mass velocity ranged from 8 to 23 kg/m(2)s and the condensation temperature difference from 1.5 to 12 K. The effect of condensate inundation was more significant for the three-dimensional fin tubes than for the low-fin tubes. In most cases, the highest performance was obtained by the tube with a three-dimensional structure at the tip of low fins. In the case of high mass velocity and high condensate inundation rate, however, the highest performance was obtained by one of the low-fin tubes. The results were compared with previous results for bundles of smooth tubes and low-fin tubes. (C) 2001 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 20 条
  • [1] Condensation of downward-flowing zeotropic mixture HCFC-123/HFC-134a on a staggered bundle of horizontal low-finned tubes
    Honda, H
    Takamatsu, H
    Takata, N
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1999, 121 (02): : 405 - 412
  • [2] Condensation of downward-flowing zeotropic mixture HCFC-123/HFC-134a on a staggered bundle of horizontal low-finned tubes
    Honda, H.
    Takamatsu, H.
    Takata, N.
    Journal of Heat Transfer, Transactions ASME, 1999, 121 (02): : 405 - 412
  • [3] Condensation of downward-flowing zeotropic mixture HCFC-123/HFC-134a on a staggered bundle of horizontal low-finned tubes
    Honda, H.
    Takamatsu, H.
    Takata, N.
    Journal of Heat Transfer, 1999, 121 (02): : 405 - 412
  • [4] Experimental measurements for condensation of downward-flowing R123/R134a in a staggered bundle of horizontal low-finned tubes with four fin geometries
    Honda, H.
    Takamatsu, H.
    Takata, N.
    International Journal of Refrigeration, 1999, 22 (08): : 615 - 624
  • [5] Experimental measurements for condensation of downward-flowing R123/R134a in a staggered bundle of horizontal low-finned tubes with four fin geometries
    Honda, H
    Takamatsu, H
    Takata, N
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (08): : 615 - 624
  • [6] Effect of fin geometry on condensation of R407C in a staggered bundle of horizontal finned tubes
    Honda, H
    Takata, N
    Takamatsu, H
    Kim, JS
    Usami, K
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (04): : 653 - 660
  • [7] Condensation heat transfer of HFC134a on horizontal low thermal conductivity tubes
    Zhang, Ding-Cai
    Ji, Wen-Tao
    Tao, Wen-Quan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2007, 34 (08) : 917 - 923
  • [8] EFFECT OF FIN GEOMETRY ON THE CONDENSATION HEAT-TRANSFER PERFORMANCE OF A BUNDLE OF HORIZONTAL LOW-FINNED TUBES
    HONDA, H
    KIM, K
    JOURNAL OF ENHANCED HEAT TRANSFER, 1995, 2 (1-2) : 139 - 147
  • [9] FILM CONDENSATION OF STEAM ON HORIZONTAL FINNED TUBES - EFFECT OF FIN SPACING
    WANNIARACHCHI, AS
    MARTO, PJ
    ROSE, JW
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1986, 108 (04): : 960 - 966
  • [10] Experimental correlation of falling film condensation on enhanced tubes with HFC134a; low-fin and Turbo-C tubes
    Kang, Yong Tae
    Hong, Hiki
    Lee, Young Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (05): : 805 - 811