Experimental investigation of pull-out resistance of uniaxial geogrids

被引:0
|
作者
Baykal, G. [1 ]
Dadasbilge, O. [1 ]
机构
[1] Bogazici Univ, Dept Civil Engn, Bebek, Turkey
关键词
pullout tests; geogrid; interaction coefficient;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The pullout performance of a locally manufactured geogrid is investigated by laboratory pullout test, performed with a modified large scale direct shear device which has been designed and constructed at Bogazici University, Due to the lack of a generally accepted standard method, all researchers have developed their own equipment. The differences in the testing procedures and equipment make the comparison of the test results difficult. But mainly the logic and effect of the various parameters on the pull out performance is the same in most of the papers presented so far. The test device presented here is a multi purpose large size direct shear device capable of conducting pull out tests. With 0.3 mX0.3mX0.3m sample box, the testing equipment is very practical. Uniaxial polypropylene geogrid and crushed rock was tested. The effects of displacement rate, confining pressure and specimen width on the pull out response have been investigated. The coefficient of interaction, which is required for the design of reinforced earth structures has been computed under different confining pressures. The results are interpreted and conclusions are presented. Comments for a better test setup are made.
引用
收藏
页码:174 / +
页数:2
相关论文
共 50 条
  • [1] The Pull-Out Resistance of Geogrids in Reinforced Soil
    Department of Civil Engineering, Kyushu University, Fukuoka 812, Japan
    不详
    不详
    不详
    Geotext. Geomembr., 1 (19-42):
  • [2] The pull-out resistance of geogrids in reinforced soil
    Ochiai, H
    Otani, J
    Hayashic, S
    Hirai, T
    GEOTEXTILES AND GEOMEMBRANES, 1996, 14 (01) : 19 - 42
  • [3] Monotonic and cyclic pull-out resistance of geogrids
    University College, University of New South Wales, Australia
    不详
    Geotechnique, 2 (331-337):
  • [4] Monotonic and cyclic pull-out resistance of geogrids
    Raju, DM
    Fannin, RJ
    GEOTECHNIQUE, 1997, 47 (02): : 331 - 337
  • [5] Research on pull-out test and frictional resistance characteristic of geogrids
    Chen, Rong
    Luan, Mao-Tian
    Zhao, Wei
    Xu, Xiao-Yan
    Hao, Dong-Xue
    Yantu Lixue/Rock and Soil Mechanics, 2009, 30 (04): : 960 - 964
  • [6] Research on pull-out test and frictional resistance characteristic of geogrids
    Chen Rong
    Luan Mao-tian
    Zhao Wei
    Xu Xiao-yan
    Hao Dong-xue
    ROCK AND SOIL MECHANICS, 2009, 30 (04) : 960 - 964
  • [7] Experimental evaluation of the factors affecting pull-out test results on geogrids
    Ghionna, VN
    Moraci, N
    Rimoldi, P
    LANDMARKS IN EARTH REINFORCEMENT, VOL 1, 2001, : 31 - 36
  • [8] Bearing force mobilisation in pull-out tests on geogrids
    Palmeira, EM
    GEOTEXTILES AND GEOMEMBRANES, 2004, 22 (06) : 481 - 509
  • [9] Pull-out test on interface behavior between expansive soils and geogrids
    Cai Jian-tao
    ROCK AND SOIL MECHANICS, 2015, 36 : 204 - 208
  • [10] A three-parameter model for the ultimate pull-out force of geogrids
    Lee, YS
    Chen, RH
    Chen, TC
    EARTH REINFORCEMENT, VOL 1, 1996, : 69 - 72