Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT

被引:137
|
作者
Ohnesorge, B
Flohr, T
Fischbach, R
Kopp, AF
Knez, A
Schröder, S
Schöpf, UJ
Crispin, A
Klotz, E
Reiser, MF
Becker, CR
机构
[1] Siemens Med Solut, Div CT, CTS C, D-91301 Forchheim, Germany
[2] Univ Munich, Dept Clin Radiol, Grosshadern Clin, D-81377 Munich, Germany
[3] Univ Tubingen, Dept Clin Radiol, D-72076 Tubingen, Germany
[4] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
关键词
cardiac CT; multisection spiral CT; coronary calcium; Agatston score; calcium volume; calcium mass;
D O I
10.1007/s00330-002-1394-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the interexamination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (21, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.
引用
收藏
页码:1532 / 1540
页数:9
相关论文
共 50 条
  • [1] Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT
    B. Ohnesorge
    T. Flohr
    R. Fischbach
    A. Kopp
    A. Knez
    S. Schröder
    U. Schöpf
    A. Crispin
    E. Klotz
    M. Reiser
    C. Becker
    European Radiology, 2002, 12 : 1532 - 1540
  • [2] Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT
    Achenbach, S
    Ulzheimer, S
    Baum, U
    Kachelriess, M
    Ropers, D
    Giesler, T
    Bautz, W
    Daniel, WG
    Kalender, WA
    Moshage, W
    CIRCULATION, 2000, 102 (23) : 2823 - 2828
  • [3] Imaging of coronary arteries by retrospectively ECG-gated spiral CT: A feasibility study
    Bahner, ML
    Boese, JM
    Delorme, S
    Wissmeier, C
    Zuna, I
    Van Kaick, G
    RADIOLOGY, 1999, 213P : 435 - 435
  • [4] Reproducibility of coronary calcium scoring with EBCT and ECG-gated multi-slice spiral CT
    Ohnesorge, BM
    Becker, CD
    Kopp, AF
    Fischbach, RM
    Knez, A
    Flohr, TG
    RADIOLOGY, 2000, 217 : 233 - 233
  • [5] Reproducibility of coronary artery calcium scores using retrospectively gated spiral CT
    Woodhouse, CE
    Mitsa, T
    Buchanan, RA
    Janowitz, WR
    White, SS
    RADIOLOGY, 1999, 213P : 352 - 353
  • [6] Comparison of coronary artery diameters in retrospectively ECG-gated multislice spiral CT and quantitative coronary angiography
    Giesler, T
    Achenbach, S
    Ropers, D
    Baum, U
    Kachelriess, M
    Ulzheimer, S
    Bautz, W
    Moshage, W
    Daniel, WG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 447A - 447A
  • [7] Noninvasive coronary angiography by retrospectively ECG-gated spiral CT using a 16-slice spiral CT scanner
    Ropers, D
    Ulzheimer, S
    Pohle, K
    Giesler, T
    Baum, U
    Wenkel, E
    Bautz, W
    Kalender, WA
    Schaller, S
    Ohnesorge, B
    Daniel, WG
    CIRCULATION, 2002, 106 (19) : 515 - 516
  • [8] Coronary calcium score is influenced by the image reconstruction interval in retrospectively ECG-gated multi-slice spiral CT
    Sinha, AM
    Mahnken, A
    Wildberger, J
    Hoffmann, R
    Guenther, RW
    Hanrath, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 357A - 357A
  • [9] Optimization of examination protocols for coronary artery calcium quantification with ECG-gated 16-slice spiral CT
    Ohnesorge, B
    Flohr, T
    Schaller, S
    Heuschmid, M
    Kuuumlttner, A
    Becker, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10C): : 61L - 62L
  • [10] Coronary artery aneurysm and type-A aortic dissection demonstrated by retrospectively ECG-gated multislice spiral CT
    Eva Fallenberg
    Kai Juergens
    Thomas Wichter
    Hans H. Scheld
    Roman Fischbach
    European Radiology, 2002, 12 : 201 - 204