Establishing Comprehensive Quality Assurance Program for Volumetric Modulated Arc Therapy - Clinical Study Using Control Point Analysis Software

被引:0
|
作者
Rong, Y. [1 ]
Jia, J. [2 ]
Sun, J. [2 ]
Gupta, N. [1 ]
机构
[1] Ohio State Univ, Med Ctr, Columbus, OH 43210 USA
[2] Sun Nucl Corp, Melbourne, FL USA
关键词
D O I
10.1118/1.4736150
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3957 / 3957
页数:1
相关论文
共 50 条
  • [1] Quality assurance of volumetric modulated arc therapy using Elekta Synergy
    Haga, Akihiro
    Nakagawa, Keiichi
    Shiraishi, Kenshiro
    Itoh, Saori
    Terahara, Atsuro
    Yamashita, Hideomi
    Ohtomo, Kuni
    Saegusa, Shigeki
    Imae, Toshikazu
    Yoda, Kiyoshi
    Pellegrini, Roberto
    ACTA ONCOLOGICA, 2009, 48 (08) : 1193 - 1197
  • [2] The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy
    Mans, Anton
    Schuring, Danny
    Arends, Mark P.
    Vugts, Cornelia A. J. M.
    Wolthaus, Jochem W. H.
    Lotz, Heidi T.
    Admiraal, Marjan
    Louwe, Rob J. W.
    Ollers, Michel C.
    van de Kamer, Jeroen B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19): : 7221 - 7235
  • [3] Multileaf Collimator Quality Assurance for Volumetric Modulated Arc Therapy
    Lin, T.
    Hossain, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3598 - U31
  • [4] Quality assurance of dynamic parameters in volumetric modulated arc therapy
    Manikandan, A.
    Sarkar, B.
    Holla, R.
    Vivek, T. R.
    Sujatha, N.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : 1002 - 1010
  • [5] Evidence based quality assurance of volumetric modulated arc therapy
    Tuemmler, H.
    Bellmann, C.
    Schilling, P.
    Schreiber, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S117 - S117
  • [6] Volumetric Modulated Arc Therapy Treatment Quality Assurance Using An Ion Chamber Array and a Software-Modified Phantom
    Han, B.
    Phillips, T.
    Luxton, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3785 - 3786
  • [7] Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    Letourneau, Daniel
    Publicover, Julia
    Kozelka, Jakub
    Moseley, Douglas J.
    Jaffray, David A.
    MEDICAL PHYSICS, 2009, 36 (05) : 1813 - 1821
  • [8] Geometric and Dosimetric Quality Assurance in Volumetric Modulated Arc Therapy (VMAT)
    Qian, J.
    Ma, Y.
    Lee, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S639 - S639
  • [9] EPID-BASED QUALITY ASSURANCE FOR VOLUMETRIC MODULATED ARC THERAPY
    Hoffmann, L.
    Jorgensen, M. B. Kyed
    Petersen, J.
    Praestegaard, L. H.
    Hansen, R.
    Muren, L. P.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S82 - S83
  • [10] Daily Quality Assurance of Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy Using Dynamic Log Files: Retrospective Study
    Tachibana, H.
    Luxton, G.
    Xing, L.
    MEDICAL PHYSICS, 2011, 38 (06)