Evaluation of mass transfer characteristics of non-porous and microporous membrane contactors for the removal of CO2

被引:26
|
作者
Ozturk, Bahtiyar [1 ]
Hughes, Ronald [2 ]
机构
[1] Ondokuz Mayis Univ, Environm Eng Dept, Eng Fac, TR-55200 Samsun, Turkey
[2] Univ Salford, Chem & Gas Eng Unit, Salford M5 4WT, Lancs, England
关键词
Non-porous membrane; Porous membrane; Gas absorption; Mass transfer; HOLLOW-FIBER MEMBRANES; CARBON-DIOXIDE CAPTURE; GAS-ABSORPTION; CO2/CH4; SEPARATION; SOLVENT-EXTRACTION; SELECTIVE REMOVAL; POWER-PLANT; FLUE-GAS; MODULES; PRESSURE;
D O I
10.1016/j.cej.2012.04.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A comprehensive experimental investigation of membrane gas absorption for the removal of carbon dioxide (CO2) using non-porous silicone rubber and porous polypropylene hollow fibre membrane contactors was performed. Water, monoethanolamine (MEA) and diethanolamine (DEA) were used as absorbing solvents. Performances of membranes for gas absorption were evaluated as mass transfer through the membranes, selectivity and removal efficiency of CO2. Water flow rate affected the mass transfer through the porous membrane more than non-porous one. But, increase in flow rate of amine solutions has not affected the mass transfer for both membranes. Mass transfer, compared with water, increased four and eight times roughly for non-porous and microporous membranes, respectively, when amine solutions of 10 wt.% were used. Amine solutions also increased the CO2 selectivity 2 and 4 folds roughly for non-porous and microporous membranes, respectively. Basic absorbents including MEA or DEA wetted the hydrophobic porous polypropylene membrane and increased the membrane resistance against the mass transfer. Increase in pressure difference between both sides of the membranes reduced the membrane CO2 selectivity. Whether water or amine solutions were used as absorbent, mass transfer through non-porous silicone rubber was mainly controlled by membrane itself. A mathematical model based on the effective permeability of the gaseous mixtures has been used to assess the performance of both membranes, and a correlation for the shell side mass transfer has been developed. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 131
页数:10
相关论文
共 50 条
  • [1] CO2 capture using highly viscous amine blends in non-porous membrane contactors
    Ansaloni, Luca
    Hartono, Ardi
    Awais, Muhammad
    Knuutila, Hanna K.
    Deng, Liyuan
    CHEMICAL ENGINEERING JOURNAL, 2019, 359 : 1581 - 1591
  • [2] Evaluation of the removal of CO2 using membrane contactors: Membrane wettability
    El-Naas, Muftah H.
    Al-Marzouqi, Mohamed
    Marzouk, Sayed A.
    Abdullatif, Nadia
    JOURNAL OF MEMBRANE SCIENCE, 2010, 350 (1-2) : 410 - 416
  • [3] Mass transfer process of CO2 absorption through non-porous hollow fibre contactor
    Sun, CG
    Cao, YM
    Zuo, L
    Lin, B
    Jie, XM
    Yuan, Q
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (11): : 2097 - 2102
  • [4] Mass transfer mechanism of CO2 absorption through a non-porous hollow fiber contactor
    Dalian Institute of Chemical Physics, CAS, Dalian 116023, China
    不详
    Gao Xiao Hua Xue Gong Cheng Xue Bao, 2007, 4 (556-562):
  • [5] Investigation of CO2 removal by silica and CNT nanofluids in microporous hollow fiber membrane contactors
    Golkhar, A.
    Keshavarz, P.
    Mowla, D.
    JOURNAL OF MEMBRANE SCIENCE, 2013, 433 : 17 - 24
  • [6] Performance evaluation of composite and microporous gas-liquid membrane contactors for CO2 removal from a gas mixture
    Amaral, R. A.
    Habert, A. C.
    Borges, C. P.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 102 : 202 - 209
  • [7] Membrane contactors for CO2 absorption - Application, modeling and mass transfer effects
    Hoff, Karl Anders
    Svendsen, Hallvard F.
    CHEMICAL ENGINEERING SCIENCE, 2014, 116 : 331 - 341
  • [8] Influence of membrane wetting on CO2 capture in microporous hollow fiber membrane contactors
    Wang, R
    Zhang, HY
    Feron, PHM
    Liang, DT
    SEPARATION AND PURIFICATION TECHNOLOGY, 2005, 46 (1-2) : 33 - 40
  • [9] Analysis of CO2 removal by hollow fiber membrane contactors
    Lee, YT
    Noble, RD
    Yeom, BY
    Park, YI
    Lee, KH
    JOURNAL OF MEMBRANE SCIENCE, 2001, 194 (01) : 57 - 67
  • [10] Gas-liquid membrane contactors for CO2 removal
    Simons, Katja
    Nijmeijer, Kitty
    Wessling, Matthias
    JOURNAL OF MEMBRANE SCIENCE, 2009, 340 (1-2) : 214 - 220