Routine ultrasound at 32 vs 36 weeks' gestation: prediction of small-for-gestational-age neonates

被引:51
|
作者
Ciobanu, A. [1 ]
Khan, N. [2 ,3 ]
Syngelaki, A. [1 ]
Akolekar, R. [2 ,3 ]
Nicolaides, K. H. [1 ]
机构
[1] Kings Coll Hosp London, Fetal Med Res Inst, 16-20 Windsor Walk,Denmark Hill, London SE5 8BB, England
[2] Medway Maritime Hosp, Fetal Med Unit, Gillingham, England
[3] Canterbury Christ Church Univ, Inst Med Sci, Chatham, Kent, England
关键词
adverse perinatal outcome; estimated fetal weight; fetal biometry; pyramid of pregnancy care; small-for-gestational age; symphysis-fundus height; third-trimester screening; FETAL-GROWTH RESTRICTION; BIRTH-WEIGHT; 3RD TRIMESTER; BIOMETRY; RISK; MANAGEMENT;
D O I
10.1002/uog.20258
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate and compare the performance of routine ultrasonographic estimated fetal weight (EFW) and fetal abdominal circumference (AC) at 31+0 to 33+6 and 35+0 to 36+6 weeks' gestation in the prediction of a small-for-gestational-age (SGA) neonate. Methods This was a prospective study of 21 989 singleton pregnancies undergoing routine ultrasound examination at 31+0 to 33+6 weeks' gestation and 45 847 undergoing routine ultrasound examination at 35+0 to 36+6 weeks' gestation. In each case, the estimated fetal weight (EFW) from measurements of fetal head circumference, AC and femur length was calculated using the Hadlock formula and expressed as a percentile according to The Fetal Medicine Foundation fetal and neonatal population weight charts. The same charts were used for defining a SGA neonate with birth weight <10th and <3rd percentiles. For each gestational-age window, the screen-positive and detection rates, at different EFW percentile cut-offs between the 10th and 50th percentiles, were calculated for prediction of delivery of a SGA neonate with birth weight <10th and <3rd percentiles within 2 weeks and at any stage after assessment. The areas under the receiver-operating characteristics curves (AUC) in screening for a SGA neonate by EFW and AC at 31+0 to 33+6 and at 35+0 to 36+6 weeks' gestation were compared. Results First, the AUCs in screening by EFW for a SGA neonate with birth weight <10th and <3rd percentiles delivered within 2 weeks and at any stage after screening at 35+0 to 36+6 weeks' gestation were significantly higher than those at 31+0 to 33+6 weeks (P<0.001). Second, at both 35+0 to 36+6 and 31+0 to 33+6 weeks' gestation, the predictive performance for a SGA neonate with birth weight <10th and <3rd percentiles born at any stage after screening was significantly higher using EFW Z-score than AC Z-score. Similarly, at 35+0 to 36+6 weeks, but not at 31+0 to 33+6 weeks, the predictive performance for a SGA neonate with birth weight <10th and <3rd percentiles born within 2 weeks after screening was significantly higher using EFW Z-score than AC Z-score. Third, screening by EFW <10th percentile at 35+0 to 36+6 weeks' gestation predicted 70% and 84% of neonates with birth weight <10th and <3rd percentiles, respectively, born within 2 weeks after assessment, and the respective values for a neonate born at any stage after assessment were 46% and 65%. Fourth, prediction of >85% of SGA neonates with birth weight <10th percentile born at any stage after screening at 35+0 to 36+6 weeks' gestation requires use of EFW <40th percentile. Screening at this percentile cut-off predicted 95% and 99% of neonates with birth weight <10th and <3rd percentiles, respectively, born within 2 weeks after assessment, and the respective values for a neonate born at any stage after assessment were 87% and 94%. Conclusions The predictive performance for a SGA neonate of routine ultrasonographic examination during the third trimester is higher if, first, the scan is carried out at 35+0 to 36+6 weeks' gestation than at 31+0 to 33+6 weeks, second, the method of screening is EFW than fetal AC, third, the outcome measure is birth weight<3rd than <10th percentile, and, fourth, if delivery occurs within 2 weeks than at any stage after assessment. Prediction of a SGA neonate by EFW <10th percentile is modest and prediction of >85% of cases at 35+0 to 36+6 weeks' gestation necessitates use of EFW <40th percentile. Copyright (c) 2019 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 50 条
  • [1] Prediction of small-for-gestational-age neonates at 35-37 weeks' gestation: contribution of maternal factors and growth velocity between 32 and 36 weeks
    Ciobanu, A.
    Anthoulakis, C.
    Syngelaki, A.
    Akolekar, R.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (05) : 630 - 637
  • [2] Prediction of small-for-gestational-age neonates at 35-37 weeks' gestation: contribution of maternal factors and growth velocity between 20 and 36 weeks
    Ciobanu, A.
    Formuso, C.
    Syngelaki, A.
    Akolekar, R.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (04) : 488 - 495
  • [3] Prediction by uterine artery Doppler screening of small-for-gestational-age neonates at 19-24 weeks' gestation
    Tai, Y. -y.
    Lee, C. -n.
    Juan, H. -c.
    Lin, M. -w.
    Liao, J. -c.
    Li, H. -y.
    Lin, S. -y.
    Poon, L. C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2024, 63 (02) : 222 - 229
  • [4] Prediction of delivery of small-for-gestational-age neonates and adverse perinatal outcome by fetoplacental Doppler at 37 weeks' gestation
    Triunfo, S.
    Crispi, F.
    Gratacos, E.
    Figueras, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 49 (03) : 364 - 371
  • [5] Competing risks model for prediction of small-for-gestational-age neonates from biophysical markers at 19 to 24 weeks' gestation
    Papastefanou, Ioannis
    Nowacka, Urszula
    Syngelaki, Argyro
    Mansukhani, Tanvi
    Karamanis, George
    Wright, David
    Nicolaides, Kypros H.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 225 (05) : 530.e1 - 530.e19
  • [6] Midtrimester Ultrasound Predictors of Small-for-Gestational-Age Neonates
    Patel, Vishal
    Resnick, Karen
    Liang, Cynthia
    Smith, Matthew
    Haghpeykar, Haleh Sangi
    Mastrobattista, Joan M.
    Gandhi, Manisha
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (10) : 2027 - 2031
  • [7] Diagnostic performance of 32 vs 36 weeks ultrasound in predicting late-onset fetal growth restriction and small-for-gestational-age neonates: a systematic review and meta-analysis
    Mustafa, Hiba J.
    Javinani, Ali
    Muralidharan, Vandana
    Khalil, Asma
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2024, 6 (01)
  • [8] Serum podocalyxin at 11–13 weeks of gestation in the prediction of small for gestational age neonates
    Daniel Lorber Rolnik
    Yao Wang
    Jonathan Hyett
    Fabricio da Silva Costa
    Guiying Nie
    Journal of Perinatology, 2019, 39 : 784 - 790
  • [9] Prediction of small-for-gestational-age at 35-37 weeks of gestation: too late for management?
    Jadli, A.
    Ghosh, K.
    Shetty, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 47 (03) : 385 - 385
  • [10] Prediction of small-for-gestational-age neonates: screening by fetal biometry at 30-34 weeks
    Bakalis, S.
    Silva, M.
    Akolekar, R.
    Poon, L. C.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 45 (05) : 551 - 558