In Vivo Cardiac Diffusion-Weighted Magnetic Resonance Imaging Quantification of Normal Perfusion and Diffusion Coefficients With Intravoxel Incoherent Motion Imaging

被引:44
|
作者
Delattre, Benedicte M. A. [1 ,2 ,3 ,4 ,5 ]
Viallon, Magalie [6 ]
Wei, Hongjiang [1 ,2 ,3 ,4 ,5 ]
Zhu, Yuemin M. [1 ,2 ,3 ,4 ,5 ]
Feiweier, Thorsten [7 ]
Pai, Vinay M. [8 ]
Wen, Han [8 ]
Croisille, Pierre [1 ,2 ,3 ,4 ,5 ,9 ]
机构
[1] CREATIS, Lyon, France
[2] CNRS, UMR 5220, Lyon, France
[3] INSERM, U1044, Lyon, France
[4] INSA Lyon, Lyon, France
[5] Univ Lyon, Lyon, France
[6] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[7] Siemens AG, Healthcare Sect, Erlangen, Germany
[8] NHLBI, Imaging Phys Lab, Biochem & Biophys Core, NIH, Bethesda, MD 20892 USA
[9] Univ St Etienne, CHU St Etienne, Hop Nord, Dept Radiol, St Etienne, France
关键词
diffusion-weighted imaging; heart; IVIM; PCA; temporal MIP; in vivo; MOTION-CORRECTION; B-VALUES; IVIM; CIRRHOSIS; LESIONS; TISSUE; T-1;
D O I
10.1097/RLI.0b013e31826ef901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Diffusion-weighted imaging (DWI) and the introduction of the intravoxel incoherent motion (IVIM) model have provided a unique method for evaluating perfusion and diffusion within a tissue without the need for a contrast agent. Despite its relevance, cardiac DWI has thus far been limited by low b values because of signal loss induced by physiological motion. The goal of this study was to develop a methodology for estimating IVIM parameters of in vivo cardiac magnetic resonance imaging using an efficient DWI acquisition framework. This was achieved by investigating various acquisition strategies (principal component analysis [PCA] filtering and temporal maximum intensity projection [PCATMIP] and single trigger delay [TD]) and fitting methods. Material and Methods: Simulations were performed on a synthetic dataset of diffusion-weighted signal intensity (SI) to determine the fitting method that would yield IVIM parameters with the greatest accuracy. The required number of b values to correctly estimate IVIM parameters was also investigated. Breath-hold DWI scans were performed for 12 volunteers to collect several TD values during diastole. Thirteen b values ranging from 0 to 550 s/mm(2) were used. The IVIM parameters derived using the data from all the acquired TDs (PCATMIP technique) were compared with those derived using a single acquisition performed at an optimized diastolic time point (1TD). Results: The main result of this study was that PCATMIP, when combined with a fitting model that accounted for T1 and T2 relaxation, provided IVIM parameters with less variability. However, an acquisition performed with 1 optimized diastolic TD provided results that were as good as those provided using PCATMIP if the R-R variability during the acquisition was sufficiently low (T5%). Furthermore, the use of only 9 b values (that could be acquired in 2 breath-holds), instead of 13 b values (requiring 3 breath-holds), was sufficient to determine the IVIM parameters. Conclusions: This study demonstrates that IVIM is technically feasible invivo and reports for the first time the perfusion fraction, f, and the diffusion coefficients, D and D*, for the cardiac DWI of healthy volunteers. Motion-induced signal loss, which is the main problem associated with cardiac DWI, could be avoided with the combined use of sliding acquisition during the cardiac cycle and image postprocessing with the PCATMIP algorithm. This study provides new perspectives for perfusion imaging without a contrast agent and demonstrates that IVIM parameters can act as promising tools to further characterize microvascular abnormalities or dysfunction.
引用
收藏
页码:662 / 670
页数:9
相关论文
共 50 条
  • [1] Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging for predicting histological grade of hepatocellular carcinoma: Comparison with conventional diffusion-weighted imaging
    Shao-Cheng Zhu
    Yue-hua Liu
    Yi Wei
    Lin-Lin Li
    She-Wei Dou
    Ting-Yi Sun
    Da-Peng Shi
    World Journal of Gastroenterology, 2018, (08) : 929 - 940
  • [2] Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging for predicting histological grade of hepatocellular carcinoma: Comparison with conventional diffusion-weighted imaging
    Zhu, Shao-Cheng
    Liu, Yue-Hua
    Wei, Yi
    Li, Lin-Lin
    Dou, She-Wei
    Sun, Ting-Yi
    Shi, Da-Peng
    WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (08) : 929 - 940
  • [3] An In Vivo Verification of the Intravoxel Incoherent Motion Effect in Diffusion-Weighted Imaging of the Abdomen
    Lemke, Andreas
    Laun, Frederik B.
    Simon, Dirk
    Stieltjes, Bram
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1580 - 1585
  • [4] Application of intravoxel incoherent motion diffusion-weighted magnetic resonance imaging on the diagnosis of breast cancer
    Chen, S.
    Wang, D.
    Kong, P.
    Gu, H.
    Yu, Z.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (04): : 827 - 832
  • [5] Diagnosis of hilar cholangiocarcinoma using intravoxel incoherent motion diffusion-weighted magnetic resonance imaging
    Xin Xu
    Abdominal Radiology, 2021, 46 : 3159 - 3167
  • [6] Diagnosis of hilar cholangiocarcinoma using intravoxel incoherent motion diffusion-weighted magnetic resonance imaging
    Xu, Xin
    ABDOMINAL RADIOLOGY, 2021, 46 (07) : 3159 - 3167
  • [7] Intravoxel incoherent motion diffusion-weighted imaging for evaluating the pancreatic perfusion in cirrhotic patients
    Ran Hu
    Guo-Fei Zeng
    Yu Fang
    Lisha Nie
    Hui-Lou Liang
    Zhi-Gang Wang
    Hua Yang
    Abdominal Radiology, 2024, 49 : 492 - 500
  • [8] Intravoxel incoherent motion diffusion-weighted imaging for evaluating the pancreatic perfusion in cirrhotic patients
    Hu, Ran
    Zeng, Guo-Fei
    Fang, Yu
    Nie, Lisha
    Liang, Hui-Lou
    Wang, Zhi-Gang
    Yang, Hua
    ABDOMINAL RADIOLOGY, 2024, 49 (02) : 492 - 500
  • [9] Progress of intravoxel incoherent motion diffusion-weighted imaging in liver diseases
    Yun-Yun Tao
    Yi Zhou
    Ran Wang
    Xue-Qin Gong
    Jing Zheng
    Cui Yang
    Lin Yang
    Xiao-Ming Zhang
    World Journal of Clinical Cases, 2020, (15) : 3164 - 3176
  • [10] An Intravoxel Incoherent Motion Diffusion-Weighted Imaging Study of Prostate Cancer
    Shinmoto, Hiroshi
    Tamura, Chiharu
    Soga, Shigeyoshi
    Shiomi, Eisuke
    Yoshihara, Nobuyuki
    Kaji, Tatsumi
    Mulkern, Robert V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (04) : W496 - W500