摘要
This article describes the results of an investigation concerning the failure of a driven gear of the turbine main oil pump in a power water cogeneration plant. The cause of the failure was determined by conducting a physical inspection, performing a detailed macro and micro examination, and examining a similar gear failure in another turbine of the plant. The failure of the driven gear was attributed to tooth-bending fatigue.
引用
收藏
页码:70 / 73
页数:4
相关论文
共 50 条
  • [1] FAILURE ANALYSIS Root Cause Failure Analysis of a Boiler Feed Pump Main Oil Pump Gear
    Mobin, M.
    Malik, A. U.
    Al-Muaili, Fahd
    Al-Hajri, M.
    MATERIALS PERFORMANCE, 2013, 52 (02) : 52 - 54
  • [2] Failure analysis of inlet oil soft pipe of main oil pump of turbine
    2000, Harbin Steam Turbine Company, China (42):
  • [3] PUMP-DRIVEN HEMOFILTRATION
    STORCK, M
    HARTL, WH
    INTHORN, D
    LANCET, 1991, 337 (8754): : 1415 - 1415
  • [4] PUMP-DRIVEN HEMOFILTRATION
    WYNCKEL, A
    TOUPANCE, O
    WONG, T
    CHANARD, J
    LANCET, 1991, 337 (8747): : 985 - 985
  • [5] Failure of an Oil Pump Bevel Gear
    Saber, Aabed Saud
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2008, 8 (05) : 419 - 425
  • [6] Failure assessment of a driven shaft of an extrusion gear pump
    Barui, KL
    Bhattacharya, B
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2005, 12 (05) : 472 - 474
  • [7] BENEFITS OF PUMP-DRIVEN HEMOFILTRATION FOR ACUTE-RENAL-FAILURE - A COMPARATIVE-STUDY
    STORCK, M
    HARTL, WH
    KIRCHDORFER, B
    INTHORN, D
    FASEB JOURNAL, 1991, 5 (05): : A1147 - A1147
  • [8] COMPARISON OF PUMP-DRIVEN AND SPONTANEOUS CONTINUOUS HEMOFILTRATION IN POSTOPERATIVE ACUTE-RENAL-FAILURE
    STORCK, M
    HARTL, WH
    ZIMMERER, E
    INTHORN, D
    LANCET, 1991, 337 (8739): : 452 - 455
  • [9] Failure Analysis of Wind Turbine Planetary Gear
    Bejger, Artur
    Frank, Ewelina
    Bartoszko, Przemyslaw
    ENERGIES, 2021, 14 (20)