Economic analysis of refrigerant blend compared to conventional R-134a based on Power consumption for air conditioning application

被引:0
|
作者
Sandeep, Sudhir [1 ]
Saravanan, A. [1 ]
机构
[1] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Sch Engn, Dept Energy & Environm Engn, Chennai 602105, Tamil Nadu, India
关键词
HFC-134a; HFO-1234yf; CYCLE_D-HX; Power consumption; cooling capacity; Evaporating temperature(Te); Air conditioning; VCR cycle; SYSTEM; PERFORMANCE; R1234YF;
D O I
10.47750/pnr.2022.13.S04.039
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim: This paper presents the power consumption analysis of refrigerants HFO-1234yf , HFC-134a and their blends at different mass fraction ratios for better performance and cooling capacity.Materials and Methodology: HFO-1234yf is an eco-friendly refrigerant with higher power consumption, HFC-134a is a refrigerant with very good COP and also with high GWP 1430. To overcome this, Tests have been carried out with blending these two refrigerants(X3, X4, X5, X6, X7) and two pure refrigerants (X1, X2) with two different evaporating temperatures (15 C and 30 C). CYCLE_D-HX simulation tool is used to enthalpy and entropy calculations. Thermodynamic analysis has been done to find out Power consumed and Cooling capacity of an air conditioning system. Statistical Packages for the Social Sciences (SPSS) software was used for determining the statistical significance between the two groups. The parameters were maintained as confidential ratio of 95%, threshold 0.01, G power 80% and enrolment ratio as 1.Results and Discussion: Results show that Power consumption at Te=15 C (0.26008 KW) for HFO-1234yf is higher than Te=30c (0.23463KW). There exists a statistically insignificant difference between the two groups (p=0.797; p>0.05).Conclusion:Te=30 C provides less power consumption and moderate cooling capacity than Te= 30C for the selected refrigerants and for the selected mass fraction ratio.
引用
收藏
页码:350 / 357
页数:8
相关论文
共 9 条
  • [1] Economic analysis of refrigerant blend compared to conventional R-134a based on Power consumption for air conditioning application
    Sandeep, Sudhir
    Saravanan, A.
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 350 - 357
  • [2] An experimenatl study on performance of automotive air conditioning system using R-134a and R-152a refrigerant
    Dae-Woong, Lee
    Yoo, Seong-Yeon
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 59 - +
  • [3] COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT
    Direk, Mehmet
    Tunckal, Cuneyt
    Yuksel, Fikret
    THERMAL SCIENCE, 2016, 20 (06): : 2065 - 2072
  • [4] Energy, exergy and entropy analysis with R1234yf as an alternate refrigerant to R134a of automobile air conditioning system
    Patel, Bhaveshkumar
    Parekh, Ashok
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (01): : 101 - 114
  • [5] Experimental analysis of the low-GWP refrigerant R1234yf as a drop-in replacement for R134a in a typical mobile air conditioning system
    Zhao, Yu
    Qi, Zhaogang
    Chen, Jiangping
    Xu, Baixing
    He, Bin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2012, 226 (C11) : 2713 - 2725
  • [6] On-road performance analysis of R134a/R600a/R290 refrigerant mixture in an automobile air-conditioning system with mineral oil as lubricant
    Ravikumar, T. S.
    Lal, D. Mohan
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (08) : 1891 - 1901
  • [7] Experimental Analysis of a Hybrid Ejector-based Air-conditioning System Using R134a
    Hao, Wang
    Cai, Wenjian
    Wang, Xinli
    2014 7TH INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION FOR SUSTAINABILITY (ICIAFS), 2014,
  • [8] Performance and Energy Consumption Analyses of R290/Bio-Based Nanolubricant as a Replacement for R22 Refrigerant in Air-Conditioning System
    Ajayi, Oluseyi O.
    Okolo, Teddy I.
    Salawu, Enesi Y.
    Owoeye, F. T.
    Akinlabu, D. K.
    Akinlabi, E. T.
    Akinlabi, S. T.
    Afolalu, S. A.
    ENERGY TECHNOLOGY 2019: CARBON DIOXIDE MANAGEMENT AND OTHER TECHNOLOGIES, 2019, : 103 - 112
  • [9] Economic analysis of the application of expanders in medium scale air-conditioners with conventional refrigerants, R1234yf and CO2
    Subiantoro, Alison
    Ooi, Kim Tiow
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (05): : 1472 - 1482