Harmonic response of adjacent structures connected with a friction damper

被引:58
|
作者
Bhaskararao, A [1 ]
Jangid, RS [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
关键词
14;
D O I
10.1016/j.jsv.2005.08.029
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The dynamic behavior of two adjacent single-degree-of-freedom structures connected with a friction damper is investigated under harmonic ground acceleration. The governing differential equations of motion of the coupled system are derived and solved for analytical harmonic response during the non-slip and slip motion in friction damper. The response of the coupled system under harmonic excitation is found to be periodic occurring in three different modes of vibration (i.e. stick-stick, stick-slip and slip-slip modes). The closed-form expressions in terms of system parameters and excitation were derived for necessary conditions to initiate the stick-stick and slip-slip modes. A parametric study is also conducted to study the influence of important system parameters on the response behavior of damper connected structures. The important parameters included are structure damping ratios, frequency ratio, mass ratio and damper slip force. It was observed that there exists an optimum slip force in the damper for which the peak displacement of a structure attains the minimum value. The friction damper with optimum slip force significantly reduces the dynamic response of the coupled structures. Finally, the influence of important parameters on the maximum displacement of friction damper is also investigated for its effective design in coupling the adjacent structures. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:710 / 725
页数:16
相关论文
共 50 条
  • [1] Dynamic response of adjacent structures connected by friction damper
    Patel, C. C.
    Jangid, R. S.
    EARTHQUAKES AND STRUCTURES, 2011, 2 (02) : 149 - 169
  • [2] Random response analysis of adjacent structures connected with friction damper
    Patel C.C.
    Asian Journal of Civil Engineering, 2021, 22 (6) : 1115 - 1129
  • [3] Dynamic response of identical adjacent structures connected by viscous damper
    Patel, C. C.
    Jangid, R. S.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (02): : 205 - 224
  • [5] Seismic response analysis of damper-connected adjacent structures with stochastic parameters
    Ge, Dong-dong
    Zhu, Hong-ping
    Wang, Dan-sheng
    Huang, Min-shui
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2010, 11 (06): : 402 - 414
  • [6] Seismic response analysis of damper-connected adjacent structures with stochastic parameters
    Dong-dong Ge
    Hong-ping Zhu
    Dan-sheng Wang
    Min-shui Huang
    Journal of Zhejiang University-SCIENCE A, 2010, 11 : 402 - 414
  • [7] Seismic Response of Adjacent Structures Connected with Semi-Active Variable Friction Dampers
    Patel, Chiragbhai Chandubhai
    Jangid, Radhey Shyam
    INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2010, 15 (01): : 39 - 46
  • [8] Seismic response of adjacent building structure connected with superelastic damper: Comparison with yield damper
    Gur, Sourav
    Singh, Pranay
    Roy, Koushik
    Proceedings of the International Conference on Structural Dynamic , EURODYN, 2020, 2 : 4696 - 4709
  • [9] Seismic response of adjacent buildings connected with friction dampers
    Bhaskararao, A. V.
    Jangid, R. S.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2006, 4 (01) : 43 - 64
  • [10] Seismic Response of Adjacent Buildings Connected with Friction Dampers
    A. V. Bhaskararao
    R. S. Jangid
    Bulletin of Earthquake Engineering, 2006, 4 : 43 - 64