Design and Implementation of Embedded Telemetry System for Amperometric Detection

被引:6
|
作者
Li Xiao-Gang [1 ]
Guo Bin-Qian [1 ]
Qin Tai-Chun [1 ]
Hao Jie [2 ]
Yu Ping [2 ]
Mao Lan-Qun [2 ]
机构
[1] Beihang Univ, Sch Reliabil & Syst Engn, Beijing 100191, Peoples R China
[2] Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Telemetry system; Miniaturization; Electrochemistry; Amperometric; Ascorbic acid; FREELY MOVING RATS; BRAIN; CONSTRUCTION; BIOSENSOR; PLATFORM;
D O I
10.11895/j.issn.0253.3820.160234
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new micro embedded telemetry system was developed for the amperometric sensing detection. Its output voltage range was +/- 0. 5 V and resolution was < 1 mV. The current acquisition range was +/- 1 mu A and the minimum resolution was 0. 2 nA. This telemetry system was designed based on microprocessor ADuCM360, including a potentiostat, a current detection module and a radio module. And the size was only 24 mm. 13 mm. 11 mm. The computer software written in LabVIEW language was used for data storage and display. In order to verify the accuracy and reliability of this system, an electrical performance test was performed. The current response for ascorbic acid with different concentration was recorded by using the telemetry system. The potential of working electrode was set as 30 mV, and the current response of ascorbic acid electrode had a good linear relationship with its concentration within the concentration range of 50-300 mu mol/L. Linear equation was I(nA) = 2. 98C(AA) (mu mol/L) - 137. 39, and linear correlation coefficient R-2 = 0. 984. Moreover, the applicability of the instrument in the study for living animals was explored by using the cerebral ischemia as model.
引用
收藏
页码:1465 / 1470
页数:6
相关论文
共 14 条
  • [1] [Anonymous], 2012, ADUCM360 ADUCM361 DA
  • [2] Biotelemetric Monitoring of Brain Neurochemistry in Conscious Rats Using Microsensors and Biosensors
    Calia, Giammario
    Rocchitta, Gaia
    Migheli, Rossana
    Puggioni, Giulia
    Spissu, Ylenia
    Bazzu, Gianfranco
    Mazzarello, Vittorio
    Lowry, John P.
    O'Neill, Robert D.
    Desole, Maria S.
    Serra, Pier A.
    [J]. SENSORS, 2009, 9 (04) : 2511 - 2523
  • [3] Ratiometric Electrochemical Sensor for Effective and Reliable Detection of Ascorbic Acid in Living Brains
    Cheng, Hanjun
    Wang, Xiaoyu
    Wei, Hui
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (17) : 8889 - 8895
  • [4] Using digital video techniques to identify correlations between behavior and the activity of single neurons
    Fenton, AA
    Muller, RU
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1996, 70 (02) : 211 - 227
  • [5] An implantable biochip to influence patient outcomes following trauma-induced hemorrhage
    Guiseppi-Elie, Anthony
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (01) : 403 - 419
  • [6] Wireless voltammetry recording in unanesthetised behaving rats
    Kagohashi, Maki
    Nakazato, Taizo
    YoshiMi, Kenji
    Moizumi, Shunjiro
    Hattori, Nobutaka
    Kitazawa, Shigeru
    [J]. NEUROSCIENCE RESEARCH, 2008, 60 (01) : 120 - 127
  • [7] A Wearable Wireless Electrochemical Instrument Used for In-vivo Neurotransmitter Detection
    Lin Nan-Sen
    Wang Li
    Wang Mi-Xia
    Xu Sheng-Wei
    Yu Wei-Dong
    Cai Xin-Xia
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (01) : 93 - 97
  • [8] Online Electrochemical Monitoring of Dynamic Change of Hippocampal Ascorbate: Toward a Platform for In Vivo Evaluation of Antioxidant Neuroprotective Efficiency against Cerebral Ischemia Injury
    Liu, Kun
    Yu, Ping
    Lin, Yuqing
    Wang, Yuexiang
    Ohsaka, Takeo
    Mao, Lanqun
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (20) : 9947 - 9954
  • [9] Michael A C, 2006, ELECTROCHEMICAL METH, P544
  • [10] Qin TC, 2015, CHINESE J ANAL CHEM, V43, P457