Free-breathing Dynamic 19F Gas MR Imaging for Mapping of Regional Lung Ventilation in Patients with COPD

被引:52
|
作者
Gutberlet, Marcel [1 ,4 ]
Kaireit, Till F. [1 ,4 ]
Voskrebenzev, Andreas [1 ,4 ]
Lasch, Florian [2 ]
Freise, Julia [3 ,4 ]
Welte, Tobias [3 ,4 ]
Wacker, Frank [1 ,4 ]
Hohlfeld, Jens M. [3 ,4 ,5 ]
Vogel-Claussen, Jens [1 ,4 ]
机构
[1] Hannover Med Sch, Inst Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, Inst Biometry, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Hannover Med Sch, Clin Pneumol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[4] German Ctr Lung Res, Biomed Res Endstage & Obstruct Lung Dis Hannover, Hannover, Germany
[5] Fraunhofer Inst Toxicol & Expt Med, Clin Airway Res, Hannover, Germany
关键词
OBSTRUCTIVE PULMONARY-DISEASE; HYPERPOLARIZED HE-3 MRI; HEALTHY-VOLUNTEERS; FRACTIONAL VENTILATION; EMPHYSEMATOUS CHANGES; QUANTIFICATION; PERFUSION; DEFECTS; SMOKERS; HUMANS;
D O I
10.1148/radiol.2017170591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify regional lung ventilation in patients with chronic obstructive pulmonary disease (COPD) by using free-breathing dynamic fluorinated (fluorine 19 [F-19]) gas magnetic resonance (MR) imaging. Materials and Methods: In this institutional review board-approved prospective study, 27 patients with COPD were examined by using breath-hold F-19 gas wash-in MR imaging during inhalation of a normoxic fluorinated gas mixture (perfluoropropane) and by using free-breathing dynamic F-19 gas washout MR imaging after inhalation of the gas mixture was finished for a total of 25-30 L. Regional lung ventilation was quantified by using volume defect percentage (VDP), washout time, number of breaths, and fractional ventilation (FV). To compare different lung function parameters, Pearson correlation coefficient and Fisher z transformation were used, which were corrected for multiple comparisons with the Bonferroni method. Results: Statistically significant correlations were observed for all evaluated lung function test parameters compared with median and interquartile range of F-19 washout parameters. An inverse linear correlation of median number of breaths (r = 20.82; P,.0001) and median washout times (r = 20.77; P,.0001) with percentage predicted of forced expiratory volume in 1 second (FEV 1) was observed; correspondingly median FV (r = 0.86; P<.0001) correlated positively with percentage predicted FEV1. Comparing initial with late phase, median VDP of all subjects decreased from 49% (25th-75th percentile, 35%-62%) to 6% (25th-75th percentile, 2%-10%; P,.0001). VDP at the beginning of the gas wash-in phase (VDP initial) significantly correlated with percentage predicted FEV 1 (r = 20.74; P =.0028) and FV (r = 0.74; P =.0002). Median FV was significantly increased in ventilated regions (11.1% [25th-75th percentile, 6.8%14.5%]) compared with the defect regions identified by VDP initial (5.8% [25th-75th percentile, 4.0%-7.4%]; P<.0001). Conclusion: Quantification of regional lung ventilation by using dynamic F-19 gas washout MR imaging in free breathing is feasible at 1.5 T even in obstructed lung segments. (C) RSNA, 2017
引用
收藏
页码:1040 / 1051
页数:12
相关论文
共 50 条
  • [1] Free-breathing Pulmonary MR Imaging to Quantify Regional Ventilation
    Capaldi, Dante P. I.
    Eddy, Rachel L.
    Svenningsen, Sarah
    Guo, Fumin
    Baxter, John S. H.
    McLeod, A. Jonathan
    Nair, Parameswaran
    McCormack, David G.
    Parraga, Grace
    RADIOLOGY, 2018, 287 (02) : 693 - 704
  • [2] Examining lung microstructure using 19F MR diffusion imaging in COPD patients
    Obert, Arnd Jonathan
    Gutberlet, Marcel
    Kern, Agilo Luitger
    Kaireit, Till Frederik
    Glandorf, Julian
    Alsady, Tawfik Moher
    Wacker, Frank
    Hohlfeld, Jens Michael
    Vogel-Claussen, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (02) : 860 - 870
  • [3] Volume-Controlled 19F MR Ventilation Imaging of Fluorinated Gas
    Obert, Arnd J.
    Kern, Agilo L.
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Kaireit, Till F.
    Crisosto, Cristian
    Greer, Mark
    Krause, E. Tobias
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1114 - 1128
  • [4] Repeatability of Regional Lung Ventilation Quantification Using Fluorinated (19F) Gas Magnetic Resonance Imaging
    Gutberlet, Marcel
    Kaireit, Till F.
    Voskrebenzev, Andreas
    Kern, Agilo L.
    Obert, Arnd
    Wacker, Frank
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    ACADEMIC RADIOLOGY, 2019, 26 (03) : 395 - 403
  • [5] Free-breathing, zero-TE MR lung imaging
    Gibiino, Fabio
    Sacolick, Laura
    Menini, Anne
    Landini, Luigi
    Wiesinger, Florian
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (03) : 207 - 215
  • [6] Free-breathing, zero-TE MR lung imaging
    Fabio Gibiino
    Laura Sacolick
    Anne Menini
    Luigi Landini
    Florian Wiesinger
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 207 - 215
  • [7] Comparison of Free-Breathing 3D Phase-Resolved Functional Lung (PREFUL) MRI With Dynamic 19F Ventilation MRI in Patients With Obstructive Lung Disease and Healthy Volunteers
    Klimes, Filip
    Obert, Arnd J.
    Scheller, Julienne
    Wernz, Marius M.
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Grimm, Robert
    Suhling, Hendrik
    Mueller, Robin A.
    Kaireit, Till F.
    Glandorf, Julian
    Moher Alsady, Tawfik
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1416 - 1431
  • [8] Editorial for "Volume-Controlled 19F MR Ventilation Imaging of Fluorinated Gas"
    Cremillieux, Yannick
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1129 - 1130
  • [9] 19F MR imaging of ventilation and diffusion in excised lungs
    Jacob, RE
    Chang, YV
    Choong, CK
    Bierhals, A
    Hu, DZ
    Zheng, J
    Yablonskiy, DA
    Woods, JC
    Gierada, DS
    Conradi, MS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 577 - 585
  • [10] Feasibility of free-breathing 19F MRI image acquisition to characterize ventilation defects in CF and healthy volunteers at wash-in
    Chung, Sang Hun
    Huynh, Khoi Minh
    Goralski, Jennifer L. L.
    Chen, Yong
    Yap, Pew-Thian
    Ceppe, Agathe S. S.
    Powell, Margret Z. Z.
    Donaldson, Scott H. H.
    Lee, Yueh Z. Z.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (01) : 79 - 89