A simplified analysis procedure is described for a fiber-reinforced plastic (FRP) stub-flanged joint which addresses some of the problems with current FRP joints. The joint consists of a tapered hub that is filament-wound with the pipe. A separate stub is used to connect the two halves of the joint. This system avoids material discontinuities at the flange-pipe intersection and pull-back of the flange, The joint is modeled following the Taylor Forge approach used in metallic joint analysis. The analytical model is verified using finite element analysis; the results are in excellent agreement.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 50 条
  • [1] Bending behavior of filament-wound fiber-reinforced sandwich pipes
    Xia, M
    Takayanagi, H
    Kemmochi, K
    COMPOSITE STRUCTURES, 2002, 56 (02) : 201 - 210
  • [2] Stiffness and strength of filament-wound fiber-reinforced composite pipes under internal pressure
    Takayanagi, H
    Xia, M
    Kemmochi, K
    ADVANCED COMPOSITE MATERIALS, 2002, 11 (02) : 137 - 149
  • [3] Exploitation and application of bamboo fiber-reinforced filament-wound pressure pipe
    Wang G.
    Deng J.
    Chen F.
    Cheng H.
    Ye L.
    Linye Kexue/Scientia Silvae Sinicae, 2016, 52 (04): : 127 - 132
  • [4] Internal pressure carrying capacity for different loading modes of filament-wound pipes from glass fiber-reinforced epoxy composites
    Abdalla, F. H.
    Sapuan, S. M.
    Hamdan, M. M.
    Sahari, B.
    POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2008, 47 (08) : 802 - 808
  • [5] Experimental study on exterior filament-wound strengthening fiber-reinforced polymer bridge decks
    Feng, Peng
    Ye, Lieping
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2009, 42 (09): : 61 - 67
  • [6] Carbon fiber-reinforced epoxy filament-wound composite laminates exposed to hygrothermal conditioning
    José Humberto S. Almeida
    Samia D. B. Souza
    Edson C. Botelho
    Sandro C. Amico
    Journal of Materials Science, 2016, 51 : 4697 - 4708
  • [7] Carbon fiber-reinforced epoxy filament-wound composite laminates exposed to hygrothermal conditioning
    Almeida, Jose Humberto S., Jr.
    Souza, Samia D. B.
    Botelho, Edson C.
    Amico, Sandro C.
    JOURNAL OF MATERIALS SCIENCE, 2016, 51 (09) : 4697 - 4708
  • [8] WIND ANGLE EFFECTS IN GLASS FIBER-REINFORCED POLYESTER FILAMENT WOUND PIPES
    ROSENOW, MWK
    COMPOSITES, 1984, 15 (02): : 144 - 152
  • [9] FIBER-REINFORCED PLASTIC PIPES AND APPLICATIONS
    AINSWORTH, L
    COMPOSITES, 1981, 12 (03): : 185 - 190
  • [10] TRANSVERSE IMPACT OF FILAMENT-WOUND PIPES
    AINSWORTH, KL
    EVANS, KE
    COMPOSITE STRUCTURES 5, 1989, : 333 - 345