The thermal characteristics of a hot wire in a near-wall flow

被引:4
|
作者
Li, WZ
Khoo, BC
Diao, X
机构
[1] Natl Univ Singapore, Dept Mech Engn, Singapore 119260, Singapore
[2] Singapore MIT Alliance, Singapore 117576, Singapore
[3] Inst High Performance Comp, Singapore 117528, Singapore
关键词
hot wire correction factor; near-wall measurement; critical Y-c(+); overheat ratio;
D O I
10.1016/j.ijheatmasstransfer.2005.06.044
中图分类号
O414.1 [热力学];
学科分类号
摘要
A two-dimensional numerical study is carried out to obtain the correction curve for the near-wall measurements by an infinitely long hot wire having been calibrated under free stream condition for the two extreme cases of isothermal and adiabatic wall conditions. Unlike previous studies particularly in experiments where the correction curve is primarily based on only the distance (h) between the wall and the wire expressed in wall units (Y+ equivalent to hUr/v), it is found that a second dimensionless parameter h(0) (equivalent to h/D) accounting for the effect of the hot wire diameter (D) is necessary to describe fully the overall near-wall correction curve. Our calculations also reveal a possible reason for the apparent discrepancy between the near-wall hot wire correction curves of Chew and Shi [Y.T. Chew, S. Shi, Wall proximity influence on hot-wire measurements, In: R.M.C. So, C.G. Speziale, B.E. Launder (Eds.), Near-Wall Turbulent Flows, Elsevier, Amsterdam, 1993, pp. 609-619] and Lange et al. [C.F. Lange, F. Durst, M. Breuer, Wall effects on heat losses from hot-wires. Int. J. Heat Fluid Flow 20 (1999) 34] next to a thermally non-conducting wall. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:905 / 918
页数:14
相关论文
共 50 条
  • [1] On near-wall hot-wire measurements
    Khoo, BC
    Chew, YT
    Teo, CJ
    EXPERIMENTS IN FLUIDS, 2000, 29 (05) : 448 - 460
  • [2] On near-wall hot-wire measurements
    B. C. Khoo
    Y. T. Chew
    C. J. Teo
    Experiments in Fluids, 2000, 29 : 448 - 460
  • [3] Time-resolved near-wall hot-wire measurements: use of laminar flow wall correction curve and near-wall calibration technique
    Natl Univ of Singapore, Singapore, Singapore
    Meas Sci Technol, 4 (564-575):
  • [4] Time-resolved near-wall hot-wire measurements: Use of laminar flow wall correction curve and near-wall calibration technique
    Khoo, BC
    Chew, YT
    Li, GL
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (04) : 564 - 575
  • [5] Correction of hot-wire measurements in the near-wall region
    C. F. Lange
    F. Durst
    M. Breuer
    Experiments in Fluids, 1999, 26 : 475 - 477
  • [6] Correction of hot-wire measurements in the near-wall region
    Lange, CF
    Durst, F
    Breuer, M
    EXPERIMENTS IN FLUIDS, 1999, 26 (05) : 475 - 477
  • [7] The flow between a rotating and a stationary disc: application to near-wall hot-wire calibration
    Khoo, BC
    Chew, YT
    Lim, CP
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 650 - 658
  • [8] On the numerical near-wall corrections of single hot-wire measurements
    Chew, YT
    Shi, SX
    Khoo, BC
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1995, 16 (06) : 471 - 476
  • [9] Experimental investigation of near-wall effects on hot-wire measurements
    Durst, F
    Zanoun, ES
    EXPERIMENTS IN FLUIDS, 2002, 33 (01) : 210 - 218
  • [10] Experimental investigation of near-wall effects on hot-wire measurements
    F. Durst
    E. Zanoun
    Experiments in Fluids, 2002, 33 : 210 - 218