The Error Analysis of Automated Biochemical Analyzer

被引:0
|
作者
Chen Qinghai [1 ,2 ]
Wu Yihui [2 ]
Li Haiwen [2 ]
Hao Peng [2 ]
Chen Qinghai [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, CIOMP, Changchun, Peoples R China
[2] GSCAS, Beijing, Peoples R China
来源
关键词
biochemical analyzer; optical absorbance; error analysis; optics system fluctuations;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to find out the relationships between the four error sources, namely, locating error, optics system fluctuations, sampling error and temperature fluctuations, and the accuracy of the instrument, we analyzed each relationship of them, and found that the effect of locating error is so tiny that it can be ignored, finally established the total error model and the model of the allowed noise of the optics system of the instrument. Analysis and the models may supply a reliable theory evidence for the improvement of the instrument and the designing of similar instruments.
引用
收藏
页码:335 / +
页数:2
相关论文
共 50 条
  • [1] The Error Analysis of Automated Biochemical Analyzer
    Chen Qinghai
    Wu Yihui
    Li Haiwen
    Hao Peng
    2010 INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING (ICBSSP 2010), 2010, : 61 - 64
  • [2] ERROR CORRECTIONS FOR AN AUTOMATED TIME-DOMAIN NETWORK ANALYZER
    SCOTT, WR
    SMITH, GS
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1986, 35 (03) : 300 - 303
  • [3] The linearity analysis and improvement of a portable biochemical analyzer
    Wang, XH
    Zhou, JQ
    Chen, ZC
    Tang, F
    Zhou, ZY
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 5606 - 5608
  • [4] ROTATING ANALYZER HETERODYNE INTERFEROMETER - ERROR ANALYSIS
    KOTHIYAL, MP
    DELISLE, C
    APPLIED OPTICS, 1985, 24 (15) : 2288 - 2290
  • [5] EVALUATION OF AN AUTOMATED TABLETOP BLOOD BIOCHEMICAL ANALYZER FOR THE VETERINARY CLINICAL PATHOLOGY LABORATORY
    SALLEE, S
    RIPPEL, R
    HOFFMANN, WE
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1990, 196 (02) : 307 - 312
  • [6] Residual Error Analysis of a Calibrated Vector Network Analyzer
    Mubarak, Faisal
    Rietveld, Gert
    2014 84TH ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG), 2014,
  • [7] AUTOMATED CHROMOSOME ANALYSIS USING THE MAGISCAN IMAGE ANALYZER
    GRAHAM, J
    TAYLOR, CJ
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1980, 2 (04): : 237 - 242
  • [8] Automated microchip platform for biochemical analysis
    Lee, WE
    Bader, DE
    Harrison, DJ
    Tang, T
    Chiem, N
    Qiu, C
    Attiya, S
    Skinner, C
    Mottl, H
    Paulson, M
    Burchett, G
    McKinnon, G
    Ning, YB
    Bekkaoui, F
    Mah, D
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 423 - 426
  • [9] CENTRIFUGAL FAST ANALYZER - NEW CONCEPT IN AUTOMATED ANALYSIS
    BURTIS, CA
    JOHNSON, WF
    SCOTT, CD
    ANDERSON, NG
    CEREAL SCIENCE TODAY, 1974, 19 (09): : 416 - 416
  • [10] AUTOMATIC BIOCHEMICAL ANALYZER
    WYLD, R
    RADIO AND ELECTRONIC ENGINEER, 1972, 42 (09): : 391 - &